Includes:
- Computer
- Chromelian Software
- Monitor
- Manuals
The DX-800 Process Analyzer is designed for reliability, accuracy, low maintenance, and regulatory compliance. Its IC and HPLC capabilities allow the determination of species that are not possible with other process analytical techniques. Multicomponent characterization of a sample can be performed in a single analysis and multiple samples can be scheduled for automatic analysis.
AE80 Enclosure
The AE80 provides the liquids and gas connections, electrical connections, electrical emissions shielding, and environmental protection necessary in a process environment.
CC80 Component Controller.
The CC80 controls the valves and pumps that perform sample selection, standard preparation, sample preparation, and chromatography. The CC80 also controls the optional SS80 Sample Selector, CH-4 Column Heater, and PC80 Post-Column Reagent Pump, if they are installed. The CC80 front panel features an interactive plumbing schematic for status and local control of the SP80 and LC80 (described in the next two sections), controls for selecting the sample source and column heater temperature, and eight alarm indicators. When the CC80 power is turned on, the Moduleware and BIOS version numbers are displayed briefly on the CC80 front panel. The CC80 is installed at the top of the enclosure, above the analytical pump and the detector.
SP80 Sample Preparation Panel
The SP80 is purchased in one of four configurations. Each configuration performs a different type of sample preparation: concentration or direct injection, dilution or direct injection, dilution with reagent addition, or concentration with reagent addition. All four configurations automatically prepare and analyze calibration standards. Components installed on the front of the SP80 panel include pumps, valves, and a dilution vessel. Electronics, air valve manifolds, and gas regulators are installed on the rear of the SP80. The panel swings open to permit access to these components. The SP80 is located inside the enclosure, directly below the analytical pump and the detector.
LC80 Liquid Chromatography Panel
The LC80 panel provides mounting for the load/inject (LI) valve, columns, conductivity detector cell, and suppressor (for conductivity detection only). If the optional column heater, column switching valve, or eluent generator is required, it is mounted on the LC80, also. The LC80 distribution board is located on the back of the swing-out panel. The LC80 is secured to the inside of the enclosure door.
Our used equipment is fully refurbished, guaranteed to work up to manufacturers specifications and are delivered to our customers in as close to new condition as possible. Typical turnaround for refurbishing of used equipment is 2-4 weeks. They also come with our standard 90-day parts and labor warranty. Prices do not include S/H unless otherwise indicated. Pictures enclosed are current manufacturer images and the actual unit may vary unless specified.