Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

At Cambridge Scientific Products, we offer an extensive range of equipment for your laboratory. Interact with our search tool below to explore our current products, or filter by a product category to see our most up to date product offerings in each of these categories.

Agilent 6890N Gas Chromatography

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 6890N Gas Chromatography

Agilent 6890N Gas Chromatography

Cambridge Scientific ID #: 15694

The Agilent/HP 6890N GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. EPC reduces re-calibration frequency and improves laboratory productivity. Designed to work seamlessly with the 6890N, the included 7683 Autosampler connects without a controller box or multiple power cords/outlets, and is packed with features including Agilent’s fast-injection technology.

 

Includes:

  • FID Detectors (Flame Ionization Detectors) OPtional
  • 7683 Autosampler (100 Vial Capacity)
  • Computer Loaded with Chemstation Software
  • Manuals and Cables

 

Features:

  • Electronic Pressure Control on detector and injector
  • Ambient temperature +4 °C to 450 °C
  • Temperature set point resolution: 1 °C
  • Supports 6 oven ramps with 7 plateaus, Negative ramps are allowed
  • Overview: Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
  • Accomplish more with networking abilities
    • Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
    • Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
  • Increased Laboratory Efficiency: Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
  • Decreased Calibration Time: You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
  • High Sample Throughput: The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
  • Minimal Rework: The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

 

Specifications:

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
  • Height: 50 cm (19.7 in.)
  • Width: 58 cm (26.8 in.)
  • Depth: 54 cm (21.6 in.)
  • Average Weight: 49 kg (108 lb)
  • Networkable: Yes
  • Ambient Operating Temperature: 15 ËšC to 35 ËšC
  • Ambient Operating Humidity: 5-95 %
  • Storage Extremes: -40ËšC to 65Ëš
  • Line Voltage Requirements: ±5% of nominal
  • Dimensions: 28 x 31 x 16 cm
  • Operating temperature: 4ËšC above ambient to 450ËšC
  • Maximum run time: 120ËšC/min
In Stock Worldwide Shipping Call: 1-877-Used-Lab

Our used lab equipment is fully refurbished, guaranteed to work up to manufacturers specifications and are delivered to our customers in as close to new condition as possible. Typical turnaround for refurbishing of used lab equipment is 2-4 weeks. They also come with our standard 6 Month parts and labor warranty. Prices do not include S/H unless otherwise indicated. Pictures enclosed and the actual unit may vary unless specified.

Inquire

Contact Us:

Thank you for your interest in the Agilent 6890N Gas Chromatography (ID #: 15694). To speak with a representative, please fill out the contact form below or call us directly.