Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Liquid: 31-45 of 191

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 16346, 13182, 16326

This Agilent 1200 Series G1365B MWD Multi-Wavelength Detector is in excellent condition!  The Agilent 1200 Series G1365B MWD multiple wavelength detector allows a wide range of wavelengths from low UV to the visible range. The diode-array based dual lamp design provides high sensitivity for trace-level quantification. Simultaneously compounds of interest can be quantified and impurities are monitored at additional wavelengths. It is recommended for the pharmaceutical QA/QC laboratory, bioscience applications (proteins, DNA) and as a general purpose UV detector for routine work The temperature management system ensures optimum baseline stability–even under rough ambient conditions. 

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-16346
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 14763

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications Controller: area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features:  Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:  
    • 1 – 100 μl in 0.1 μl increments
    • Up to 1500 μl with multiple draw (hardware modification required)
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 μl,
    • Typically < 1 % RSD from 1 – 5 μl
  • Sample viscosity range:  0.2 – 5 cp
  • Sample capacity:
    • 2 × well-plates (MTP) + 10 × 2 ml vials
    • 100x2ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically < 30 s using following standard conditions:
    • Default draw speed: 200 μl/min
    • Default eject speed: 200 μl/min
    • Injection volume: 5 μl
  • Carry-over Typically:
    • < 0.01 % using the following conditions:
    • Column: 125 x 4 mm Hypersil ODS, 5 μm
    • Mobile phase: Water/Acetonitrile = 80/20
    • Flow rate: 1 ml/min
    • Injection volume: 1 μl caffeine (1 mg/ml), 5 μl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port

 

Learn More
Agilent-1100-Series---G1367A-HPLC-Well-Plate-Autosampler-14763
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1376A HPLC Capillary Pump

Agilent 1100 Series - G1376A HPLC Capillary Pump

Cambridge Scientific ID #'s: 9564, 15081

Specifications:

  • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
  • Settable column flow Range:
    • – 20 µl/min
    • – 100 µl/min (with the extended flow range kit)
    • – 2.5 µl/min (with the electronic flow control bypassed)
  • Recommended column flow range:
    • – 20 µl/min
    • 10 – 100 µl/min (with extended flow range kit)
    • – 2.5 ml/min (with the electronic flow sensor bypassed)
  • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
  • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
  • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
  • Delay volume:
    • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
    • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
    • for flow rates up to 100 µl/min and electronic flow control active:
    • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
    • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
  • Pressure range: 20 to 400 bar (5880psi) system pressure
  • Compressibility Compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog output For pressure monitoring, 2 mV/bar, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
  • Housing: All materials recyclable
Learn More
Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Cambridge ID #: 13766

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • – 8 µl in 0.01 µl increments with the small loop capillary
    • – 40 µl in 0.01 µl increments with the extended loop capillary
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 40 µl,
    • Typically < 1 % RSD from 1 – 5 µl
    • Typically < 3 % RSD from 0.2 – 1 µl
  • Sample viscosity range: 2 – 5 cp
  • Sample capacity:
    • 2× well-plates (MTP) + 10 × 2 ml vials
    • 100 x 2 ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically, < 30 s using following standard conditions:
    • Default draw speed: 4 µl/min
    • Default eject speed: 10 µl/min
    • Injection volume: 0.1 µl
  • Carry-over:
    • Typically < 0.05 % using the following conditions:
    • Column: 150 x 0.5 mm Hypersil ODS, 3 µm
    • Mobile phase: Water/Acetonitrile = 85/15
    • Column Flow rate: 13 µl/min
    • Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port
Learn More
Agilent-1100-Series---G1377A-HPLC-Well-Plate-Autosampler-13766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 15934, 16078, 16060, 16141, 10201, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-15934
By clicking below we can further assist you with your inquiry. Inquire 7 In Stock Worldwide Shipping
Agilent 1100 Series - G1389A HPLC Autosampler

Agilent 1100 Series - G1389A HPLC Autosampler

Cambridge Scientific ID #'s: 9301, 16033, 10407

Specifications:

  • Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
  • Settable injection volume
    • to 8 µl with small loop capillary
    • to 40 µl with extended loop capillary
  • Precision
    • Typically < 0.5 % RSD from 5 to 40 µl
    • Typically < 1 % RSD from 1 to 5 µl
    • Typically < 3 % RSD from 0.2 to 1 µl
  • Minimum sample volume: µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
  • Carryover
    • Typically < 0.1 % without automated needle wash
    • Typically < 0.05 % with external needle cleaning and 1 µl injection volume
  • Sample viscosity range: 2 - 5 cp
  • Recommended pH-range: - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
  • Material in contact with solvent: Stainless steel, sapphire, PTFE, PEEK, fused silica
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in aintenance areas, error detection and display
  • Housing: All material recyclable

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1389A-HPLC-Autosampler-9301
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1946C LC/MS System

Agilent 1100 Series - G1946C LC/MS System

Cambridge Scientific ID #'s: 12805, 13523

Optional Service Contract, Installation, and training

 

Includes:

  • G1946C
  • LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional HPLC
  • Computer with Chemstation Software

 

Specifications:

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run

 

Learn More
Agilent-1100-Series---G1946C-LC-MS-System-12805
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1946D LC/MS System

Agilent 1100 Series - G1946D LC/MS System

Cambridge Scientific ID #'s: 10994, 12803, 12804

Includes Installation and One year Service Contract

 

Includes:

  • G1946D LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional Front end HPLC

Specifications

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed:
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1946D-LC-MS-System-10994
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1956B LC/MS System

Agilent 1100 Series - G1956B LC/MS System

Cambridge ID #: 11790

Optional Front End, Service Contract, Installation, and Training

Specifications:

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1956B-LC-MS-System-11790
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9592, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - Solvent Tray HPLC Solvent TrayImage Coming Soon

Agilent 1100 Series - Solvent Tray HPLC Solvent Tray

Cambridge ID #: 7147

Agilent 1100 HPLC Solvent Tray for HPLC Systems used to hold containers and organize solvent lines

Learn More
Agilent-1100-Series---Solvent-Tray-HPLC-Solvent-Tray-7147
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Cambridge ID #: 15899

Specifications: 

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Noise: ± 0.75 x 10 -5 AU, at 254 nm
  • Drift: 3 x 10-4AU/hr, at 254 nm
  • Linearity: >2 AU upper limit
  • Wavelength range: 190-600 nm
  • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
  • Maximum data rate: 55 Hz
Learn More
Agilent-1200-Series---G1314C-HPLC-Variable-Wavelength-Detector-15899
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Cambridge ID #: 16187

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment---Heater-16187
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G1322A HPLC Degasser

Agilent 1200 series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 16301, 16328

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1200-series---G1322A-HPLC-Degasser-16301
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping