Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Spectrometers / Spectrophotometers ranging from Spectrofluorometer, Fluorescence, Atomic Absorption (AA), ICP, to UV / Vis / NIR Spectrometers and Microplate. Some of our popular manufacturers include Beckman, Perkin Elmer, HP, Hitachi, Varian and Bio-Tek. We have one of the largest inventories of Mass Spectrometers available. We also offer service contracts, installation and training. Browse our inventory of used mass spec products below.

Spectrophotometers: 16-28 of 28

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Perkin Elmer Lambda 25 Spectrophotometer UV/Vis Reader

Perkin Elmer Lambda 25 Spectrophotometer UV/Vis Reader

Cambridge Scientific ID #'s: 16946, 11107

Versatile spectrometers operating in the ultraviolet (UV) and visible (Vis) spectral ranges. Optical components are coated with silica for durability and holographic grating is used in the monochromator. Features a double-beam, all-reflecting system, usable for a wide range of applications.

 

Includes:

  • Computer loaded w/ software
  • 6 cell Cuvette Holder
  • Peltier Port

Modes Of Operation:

  • Scanning
  • Wavelength program
  • Time-drive
  • Rate
  • Quant
  • Scanning quant

Features:

  • True double-beam operation
  • High throughput, low stray-light optics
  • Pre-aligned deuterium and tungsten-halogen lamps
  • Wide range of accessories and consumables

Benefits:

  • Very high stability, high accuracy and reproducibility.
  • Easily passes all pharmacopoeia and regulatory performance tests
  • Quickly replaced for minimal downtime
  • Perfect for any liquid sample
  • Select the version that best matches your analysis needs and the skill level of your operators

Applications:

  • Routine UV/ Vis Testing
  • Liquids Analysis
  • Solids, Pastes, and Powder Samples
  • Regulatory Tests requiring variable bandwidths

Specifications:

  • Temperature Range: Ambient 15ºC to 35ºC
  • Relative Humidity: 20% to 80% (without condensation)
  • Dimensions: 650 x  560 x 260 nm (W x D x H)
  • Wavelength Range: 190 nm to 1100 nm
  • Wavelength Accuracy: ±0.1 nm
  • Wavelength Reproducibility: ±0.1 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
  • Beam Center Height: 15 mm
  • Optical Path Length: 121 mm
  • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
  • Photometric Range: 0% to 100%
  • Detector: Photodiodes
  • Grating: Holographic, 1053 lines/mm
  • Lamp Change: Automatically at 326 nm
  • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
  • Digital Port: One RS 232 C Interface
  • Type: Scanning Double-Beam
  • Pollution Degree: 2
  • Altitude: Up to 2000 m
Learn More
Perkin-Elmer-Lambda-25-Spectrophotometer-UV-Vis-Reader-16946
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Perkin Elmer Lambda 35 Spectrophotometer UV/Vis Reader

Perkin Elmer Lambda 35 Spectrophotometer UV/Vis Reader

Cambridge ID #: 15568

Versatile spectrometers operating in the ultraviolet (UV) and visible (Vis) spectral ranges. Optical components are coated with silica for durability and holographic grating is used in the monochromator. Features a double-beam, all-reflecting system, usable for a wide range of applications.

 

Includes:

  • Computer loaded w/ software
  • 6 cell Cuvette Holder
  • Peltier Port

Modes Of Operation:

  • Scanning
  • Wavelength program
  • Time-drive
  • Rate
  • Quant
  • Scanning quant

Features:

  • True double-beam operation
  • High throughput, low stray-light optics
  • Pre-aligned deuterium and tungsten-halogen lamps
  • Wide range of accessories and consumables

Benefits:

  • Very high stability, high accuracy and reproducibility.
  • Easily passes all pharmacopoeia and regulatory performance tests
  • Quickly replaced for minimal downtime
  • Perfect for any liquid sample
  • Select the version that best matches your analysis needs and the skill level of your operators

Applications:

  • Routine UV/ Vis Testing
  • Liquids Analysis
  • Solids, Pastes, and Powder Samples
  • Regulatory Tests requiring variable bandwidths

Specifications:

  • Temperature Range: Ambient 15ºC to 35ºC
  • Relative Humidity: 20% to 80% (without condensation)
  • Dimensions: 650 x  560 x 260 nm (W x D x H)
  • Wavelength Range: 190 nm to 1100 nm
  • Wavelength Accuracy: ±0.1 nm
  • Wavelength Reproducibility: ±0.1 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
  • Beam Center Height: 15 mm
  • Optical Path Length: 121 mm
  • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
  • Photometric Range: 0% to 100%
  • Detector: Photodiodes
  • Grating: Holographic, 1053 lines/mm
  • Lamp Change: Automatically at 326 nm
  • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
  • Digital Port: One RS 232 C Interface
  • Type: Scanning Double-Beam
  • Pollution Degree: 2
  • Altitude: Up to 2000 m
Learn More
Perkin-Elmer-Lambda-35-Spectrophotometer-UV-Vis-Reader-15568
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perkin Elmer Lambda 40 Spectrophotometer UV/Vis Reader

Perkin Elmer Lambda 40 Spectrophotometer UV/Vis Reader

Cambridge ID #: 16658

Versatile spectrometers intended for routine ultraviolet (UV) and visible (Vis) analysis. Featuring a double-beam, all-reflecting system, usable for a wide range of applications.

 

Specifications:

 

  • Temperature Range: Ambient 15ºC to 35ºC
  • Relative Humidity: 20% to 80% (without condensation)
  • Dimensions: 650 x  560 x 260 nm (W x D x H)
  • Wavelength Range: 190 nm to 1100 nm
  • Wavelength Accuracy: ±0.3 nm
  • Wavelength Reproducibility: ±0.1 nm
  • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
  • Beam Center Height: 15 mm
  • Optical Path Length: 121 mm
  • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
  • Photometric Range: 0% to 100%
  • Detector: Photodiodes
  • Grating: Holographic, 1053 lines/mm
  • Lamp Change: Automatically at 326 nm
  • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
  • Digital Port: One RS 232 C Interface
  • Type: Scanning Double-Beam
  • Pollution Degree: 2
  • Altitude: Up to 2000 m
Learn More
Perkin-Elmer-Lambda-40-Spectrophotometer-UV-Vis-Reader-16658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perkin Elmer Optima 4200DV ICP/OES

Perkin Elmer Optima 4200DV ICP/OES

Cambridge ID #: 13703
  • Perkin Elmer 4200 DV ICP Optical Emission Spectrometer
  • Learn More
    Perkin-Elmer-Optima-4200DV-ICP-OES-13703
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Perkin Elmer Spectrum 1000 FT-IR Spectrophotometer

    Perkin Elmer Spectrum 1000 FT-IR Spectrophotometer

    Cambridge ID #: 13614

    Specifications:

    • Mid-IR Kbr beamsplitter
    • Wavelength Range: Optimum 4000cm-1 to 450cm-1
    • Resolution: 1cm-1
    • Detector: DTGS
    • Optics: Sealed and desiccated. Purgeable
    • Computer loaded w/ PE Spectrum Windows Software
    Learn More
    Perkin-Elmer-Spectrum-1000-FT-IR-Spectrophotometer-13614
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Spectronic Genesys 5 Spectrophotometer Visible/Absorbance Reader

    Spectronic Genesys 5 Spectrophotometer Visible/Absorbance Reader

    Cambridge ID #: 17246

    Handle a wide range of routine and complex applications—perform simple absorbance measurements, determine sample concentrations or run a rate analysis. 

    Specifications:

    • Optical System: Split-Beam

    • Cell-Holder: 8-position, Microprocessor-Controlled

    • Communication Ports: RS-232-C (Serial) / Centronics-Compatible (Parallel)

    • Wavelength Range: 200 - 1100nm

    • Wavelength Accuracy: ±1nm

    • Wavelength Precision: ±0.5nm (ASTM E 275–83)

    • Photometric Readout: Absorbance, %Transmittance and Concentration

    • Photometric Range: -0.1 to +3.0A; 0 to 125%T; 0.001 to 9999

    • Photometric Accuracy: ±0.003A from 0 to 0.3A, ±1% of Reading from 0.3 to 2A, ±2% of Reading from 2 to 3A

    • Photometric Drift: 0.002A/hour at 340nm

    Learn More
    Spectronic-Genesys-5-Spectrophotometer-Visible-Absorbance-Reader-17246
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Forma Genesys 20 Spectrophotometer Visible/Absorbance Reader

    Thermo Forma Genesys 20 Spectrophotometer Visible/Absorbance Reader

    Cambridge ID #: 13128

    Multiple purpose capabilities allow you to measure a wide range of analytes.

     

    Features:

    • Compact footprint provides a space-saving, convenient system
    • Intuitive keyboard with integrated controls and LCD display
    • Routine measurements require just a few keystrokes
    • Direct measurement of routine absorbance or transmittance data
    • Concentration mode for single point standard or factor-based quantitative analysis
    • Bidirectional RS-232-C interface

     

    Specifications

    • Optical System: Grating based, 1200 lines/mm
    • Spectral Bandwidth: <=8nm
    • Wavelength Range: 325 to 1100nm
    • Wavelength Accuracy: ±2.0nm
    • Wavelength: Readout: 20-character, 2-line LCD
    • Readout: Absorbance, %Transmittance, Concentration
    • Range:
      • -0.1 to +2.5A
      • 0 to 125%T
      • 0 to 1999C
    • Accuracy:
      • ±0.003A from 0 to 0.3A
      • ±1% from 0.3 to 2.5A
    • Noise (at 500nm): <=0.001A at 0A; ±0.004A at 2A
    • Drift: 0.003A/hour
    • Stray Radiant Energy: <=0.1%T at 340 and 400nm
    • Communication Ports
      • RS-232-C (serial)
      • Centronics-compatible (parallel)
    • Dimensions: 13L x 12W x 7 in.H (33 x 30 x 19cm)
    • Net Weight: 10 lb. (4.5kg)
    Learn More
    Thermo-Forma-Genesys-20-Spectrophotometer-Visible-Absorbance-Reader-13128
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Forma Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Thermo Forma Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 17429

    Features:

    Enhance the limit of detection for DNA, RNA and protein with the Thermo Scientific NanoDrop 2000c UV-Vis spectrophotometer featuring both microvolume pedestal and cuvette measurement options. The cuvette station is ideal for measuring dilute nucleic acid and protein assays, includes heating and microstirring capabilities, and allows users to perform kinetics and cell culture readings (600nm).

    • Wide spectral range (190-840nm) for measuring a variety of samples types:
      • Peptides (205nm)
      • DNA and RNA (260nm)
      • Purified protein (280nm)
      • Toxicology assays and industrial dyes (490nm)
      • Gold nanoparticles (520nm)
      • Colorimetric protein assays (BCA 562nm, Bradford 595nm, Modified Lowry 650nm, Pierce 660 660nm)
      • Optical Density measurements (600nm)
    • Combining the patented sample retention system with cuvette capability accommodates low and high concentrations
      (0.4 to 15,000 ng/µL dsDNA and 0.01 – 400 mg/mL BSA)
    • Pedestal measurements that require only 0.5 – 2 µL of your sample and do not require sample dilution, even for highly concentrated samples
    • Calculates sample purity ratios (260/280 nm and 260/230 nm)
    • Pre-configured methods for DNA, Protein A280, Microarray, Protein and Labels, Pierce 660, Bradford, BCA, and Lowry
    • Fast measurement time of less than 5 seconds, 10 -15 seconds from sample pipette to wipe
    • User-friendly software that includes custom methods and data export capabilities

    Nanodrop 2000C Specifications:

    • Instrument Type: Spectrophotometer  
    • Minimum Sample Volume: 0.5 µl
    • Recommended Sample Volume, Nucleic acid: 1 µl
    • Recommended Sample Volume, Proteins: 2 µl
    • Sample Number: 1
    • Path Length: 1 mm (auto-ranging to 0.05 mm)
    • Light Source(s): Xenon flash lamp
    • Detector Type: 2048 - element linear silicon CCD array
    • Wavelength Range: 190 - 840 nm
    • Wavelength Accuracy: 1 nm
    • Spectral Resolution: ≤ 1.8 nm (FWHM at Hg 253.7 nm)
    • Absorbance Precision: 0.002 (1 mm path)
    • Absorbance Accuracy: 3% (at 0.74 at 350 nm)
    • Absorbance Range: 0.04 - 300 (10 mm equivalent)
    • Detection Limit: 2 ng/µl (dsDNA)
    • Maximum Concentration: 15,000 ng/µl (dsDNA)
    • Measurement Time: 5s (typical)
    • Footprint: 14 x 20 cm
    • Weight: 2.1 kg
    • Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
    • Operating Voltage: 12 vdc
    • Operating Power Consumption: 12 - 18 W (max 30 W)
    • Standby Power Consumption: 5 W
    • Software Compatibility: Operating software for the NanoDrop 2000 and NanoDrop 2000c. Compatible with Professional versions of Windows 8.1 (64 bit), and Windows 7 (32 and 64 bit).    

    Cuvette Specifications:   

    • Z-Height: 8.5 mm
    • Heating: 37 ± 0.5 °C
    • Stirrer: 150-850 rpm
    • Path Length: 10, 5, 2, 1 mm
    • Absorbance Range: 0.008 - 1.5
    • Detection Limit: 0.4 ng/µl (dsDNA)
    • Maximum Concentration: 750 ng/µl (dsDNA)
    • Measurement Time: < 3 seconds
    • Cuvette Dimensions: 12.5 mm x 12.5 mm, up to 48 mm H
    • Type: Masked cuvette
    • UL/CSA and CE: All units are approved to these standards
    Learn More
    Thermo-Forma-Nanodrop-2000-Spectrophotometer-UV-Vis-Reader-17429
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Forma Nanodrop ND-3300 Fluorospectrometer

    Thermo Forma Nanodrop ND-3300 Fluorospectrometer

    Cambridge ID #: 16304

    The NanoDrop 3300 significantly lowers the mass detection limit more than an order of magnitude, compared to conventional fluorometers. With its advanced features and analysis options, the NanoDrop 3300 allows for a diverse range of measurements from routine RiboGreen, PicoGreen, and GFP to advanced nanoparticle and FRET analysis.

    Specifications:

    • Excitation Wavelength: UV: 265nm, Blue: 470nm, White: 460-650nm
    • Depth: 20 cm
    • Width: 14 cm
    • Weight:5 kg (3.3 lb)
    • Wavelength Range: 400 – 750 nm
    • Wavelength Accuracy: +/- 1 nm
    • Volume Sample: 1 uL
    Learn More
    Thermo-Forma-Nanodrop-ND-3300-Fluorospectrometer-16304
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Nicolet 6700 FT-IR Spectrophotometer

    Thermo Nicolet 6700 FT-IR Spectrophotometer

    Cambridge ID #: 12762

    Includes:

    • NXR FT-Raman Accessory Module )1064 nm Laser)
    • Raman InGaAs Detector
    • Nicolet/Nexus Series Sample Compartment Cover
    • 180 Degree Reflective Sample Comp Dual Motor Assembly
    • Raman Capillary Tube Holder
    • FT Raman MicroStage
    • Computer Loaded w/ Atlus Software, and FTIR Software

     

     

    Nicolet FT-IR spectrometers from Thermo Electron Corporation are the highest performance FT-IR systems available. While the spectrometer has the power to handle the most advanced research-level experiments, routine analyses are performed just as conveniently.  Every facet of the Nicolet FT-IR spectrometer has been engineered to facilitate sample handling, introduce options to scientists, and increase laboratory throughput.

     

    Specifications:

    • Spectral Range (Standard): 7800 – 350 cm-1
    • Spectral Range (Option, CsI Optics): 6400 – 200 cm-1
    • Spectral Range (Option, Extended-Range Optics): 11000 – 375 cm-1
    • Spectral Range (Option, Multi-Range Optics): 27000 – 15 cm-1 (Standard)
    • Optical Resolution: 09 cm-1
    • Peak-To-Peak Noise (1 minute scan): < 8.68 x 10^-6 AU** (50,000:1)
    • RMS Noise (1 minute scan): < 1.95 x 10-6 AU**
    • Ordinate Linearity: 07 %T
    • Wavenumber Precision: 01 cm
    • Slowest Linear Scan Velocity: 0.158 cm/sec
    • Fastest Linear Scan Velocity: 33 cm/sec
    • Number of Scan Velocities: 15
    • Rapid Scan (Spectra/second @ 16 cm-1, 16 cm-1: 65, 95
    • Throughput Increase in Turbo Mode (@ 3000 cm: 25%
    • Liquid Nitrogen-Cooled Detector Hold Time: 18 hours
    Learn More
    Thermo-Nicolet-6700-FT-IR-Spectrophotometer-12762
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Scientific NanoDrop ND-1000 Spectrophotometer UV/Vis Reader

    Thermo Scientific NanoDrop ND-1000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 17894

    Includes:
    • Computer w/ Software
    • Necessary Cables
    • Manual

    The NanoDrop 1000 Spectrophotometer measures 1 ul samples with high accuracy and reproducibility. The full spectrum (220nm-750nm) spectrophotometer utilizes a patented sample retention technology that employs surface tension alone to hold the sample in place. This eliminates the need for cumbersome cuvettes and other sample containment devices and allows for clean up in seconds. In addition, the NanoDrop 1000 Spectrophotometer has the capability to measure highly concentrated samples without dilution (50X higher concentration than the samples measured by a standard cuvette spectrophotometer).

    UV/VIS spectrophotometry is simple for samples as small as 1 ul using the NanoDrop 1000 Spectrophotometer. The small sample requirement and ease of use make the NanoDrop 1000 Spectrophotometer ideally suited for measuring:
    • Nucleic acid concentration and purity of nucleic acid samples up to 3700 ng/ul (dsDNA) without dilution
    • Fluorescent dye labeling density of nucleic acid microarray samples
    • Purified protein analysis (A280) up to 100 mg/ml (BSA)
    • Expanded spectrum measurement and quantitation of fluorescent dye labeled proteins, conjugates, and metalloproteins
    • Bradford Assay analysis of protein
    • BCA Assay analysis of protein
    • Lowry Assay analysis of protein
    • Pierce Protein 660 nm Protein Assay
    • Cell density measurements
    • General UV-Vis spectrophotometry

    Specifications:

    • Sample Size: 1 microliter
    • Path Length: 1 mm (with auto-ranging to 0.2 mm)
    • Light Source: Xenon flash lamp
    • Detector Type: 2048-element linear silicon CCD array
    • Wavelength Range: 220-750 nm
    • Wavelength Accuracy: 1 nm
    • Wavelength Resolution: 3 nm (FWHM at Hg 546 nm)
    • Absorbance Precision: 0.003 absorbance ( 1mm path)
    • Absorbance Accuracy: 2% (at 0.76 absorbance at 257 nm)
    • Absorbance Range: 0.02-75 (10 mm equivalent absorbance)
    • Detection Limit: 2 ng/microliter (dsDNA)
    • Maximum Concentration: 3700 ng/microliter (dsDNA)
    • Measurement Cycle Time: 10 seconds
    • Dimensions: 14 cm X 20 cm
    • Weight: 1.6 kg
    • Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
    • Operating Voltage: 12 Vdc
    • Operating Power Consumption: 6 W
    • Standby Power Consumption: 1.5 W Heating : 37 ± 0.5 °C
    Learn More
    Thermo-Scientific-NanoDrop-ND-1000-Spectrophotometer-UV-Vis-Reader-17894
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Spectronic Genesys 20 Spectrophotometer Visible/Absorbance Reader

    Thermo Spectronic Genesys 20 Spectrophotometer Visible/Absorbance Reader

    Cambridge Scientific ID #'s: 16869, 13375, 16872

    Multiple purpose capabilities allow you to measure a wide range of analytes.

     

    Features:

    • Compact footprint provides a space-saving, convenient system
    • Intuitive keyboard with integrated controls and LCD display
    • Routine measurements require just a few keystrokes
    • Direct measurement of routine absorbance or transmittance data
    • Concentration mode for single point standard or factor-based quantitative analysis
    • Bidirectional RS-232-C interface

     

    Specifications

    • Optical System: Grating based, 1200 lines/mm
    • Spectral Bandwidth: <=8nm
    • Wavelength Range: 325 to 1100nm
    • Wavelength Accuracy: ±2.0nm
    • Wavelength: Readout: 20-character, 2-line LCD
    • Readout: Absorbance, %Transmittance, Concentration
    • Range:
      • -0.1 to +2.5A
      • 0 to 125%T
      • 0 to 1999C
    • Accuracy:
      • ±0.003A from 0 to 0.3A
      • ±1% from 0.3 to 2.5A
    • Noise (at 500nm): <=0.001A at 0A; ±0.004A at 2A
    • Drift: 0.003A/hour
    • Stray Radiant Energy: <=0.1%T at 340 and 400nm
    • Communication Ports
      • RS-232-C (serial)
      • Centronics-compatible (parallel)
    • Dimensions: 13L x 12W x 7 in.H (33 x 30 x 19cm)
    • Net Weight: 10 lb. (4.5kg)
    Learn More
    Thermo-Spectronic-Genesys-20-Spectrophotometer-Visible-Absorbance-Reader-16869
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Unico 1100RS Spectrophotometer Visible/Absorbance Reader

    Unico 1100RS Spectrophotometer Visible/Absorbance Reader

    Cambridge ID #: 3862

    Features:

    • Dynamic Range of 335-1000 nm
    • Maintenance-free Wavelength Knob with built-in Metal Stopper
    • Data Port : USB
    • Auto zero function
    • Easy to read display
    • Flexible Sample Compartment
    • Solid State Detector for entire wavelength range
    • Built-in filters to ease operation

     

    Specifications:

    • Bandpass: 10 nm
    • Monochromator: single beam, grating system 1200 lines/ mm
    • Wavelength range: 335-1000 nm
    • Wavelength accuracy: ±2 nm
    • Photometric range: 0-125%T, 0-2A, 0-1999C (0-1999F)
    • Data port: USB
    • Light Source: Tungsten Halogen Lamp
    • Power Requirements: 110V/50Hz, 230V/60Hz switchable
    • Size:1 x 12.1 x 7.1 inch (408 x 308 x 185 mm)
    • Weight:2 lbs (6 kg)
    Learn More
    Unico-1100RS-Spectrophotometer-Visible-Absorbance-Reader-3862
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping