Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 15535, 15536, 15502, 16331, 15503, 15354, 17331, 16037, 15998

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-15535
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 15227, 16189, 14777, 15501, 15508, 16031, 15189, 15135, 15356, 15353, 17335, 16030, 15504, 15999, 15289

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-15227
By clicking below we can further assist you with your inquiry. Inquire 15 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 15223, 16338

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-15223
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge ID #: 9592

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1329A Autosampler
  • G1330 Autosampler Chiller
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9592
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16330, 16315, 15076

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-16330
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - HPLC Stack HPLC System

Agilent 1200 Series - HPLC Stack HPLC System

Cambridge ID #: 9593

Includes:

  • Agilent G1322A Degasser
  • Agilent G1311A Quat Pump
  • Agilent G1329A Autosampler
  • Agilent G1330A Autosampler Chiller
  • Agilent G1365D DAD (Diode Array Detector)
  • Agilent G1316A Column Compartment
  • Solvent Tray
  • Computer Loaded with ChemStation
  • Cables and Manuals
Learn More
Agilent-1200-Series---HPLC-Stack-HPLC-System-9593
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Life 888 EMCCD  Microscope Camera

Andor Technology iXon Life 888 EMCCD Microscope Camera

Cambridge ID #: 16888

Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

Specifications:

  • Sensor Type: Back Illuminated, standard AR coated
  • Active pixels (H x V): 1024 x 1024
  • Pixel Size (H x V: µm): 13 x 13
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Active Area Pixel Well Depth (e-): 80,000 180,000
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 30 MHz•3 -55ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 30 MHz•3 -65ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•6: 730,000 e-
  • Read noise (e-) •7: <1
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp accuracy: 10 ns

 

 

 

 

 

Learn More
Andor-Technology-iXon-Life-888-EMCCD-Microscope-Camera-16888
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Life 897 EMCCD Microscope Camera

Andor Technology iXon Life 897 EMCCD Microscope Camera

Cambridge ID #: 16889

Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

Specifications:

  • Sensor Type: Back Illuminated, standard AR coated
  • Active pixels (H x V): 512 x 512
  • Pixel Size (H x V: µm): 16 x 16 μm
  • Image Area: 8.2 x 8.2 mm with 100% Fill Factor
  • Active Area Pixel Well Depth (e-): 80,000 180,000
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 17 MHz•3 -70ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 17 MHz•3 -80ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 2.0
  • Lens Mount: C-mount
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00030
  • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.0018
  • Active Area Pixel Well Depth: 180,000 e
  • Gain Register Pixel Well Depth•6: 800, 000 e
  • Read noise (e-) •7: <1
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.3 to 3.3 µs (user selectable)
  • Timestamp accuracy: 10 ns

 

 

 

 



 

 

 

 

 

Learn More
Andor-Technology-iXon-Life-897-EMCCD-Microscope-Camera-16889
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 BVF USB3 EMCCD Microscope Camera

Andor Technology iXon Ultra 888 BVF USB3 EMCCD Microscope Camera

Cambridge ID #: 16875

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, standard AR coated with fringe suppression
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate:
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-BVF-USB3-EMCCD-Microscope-Camera-16875
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 EX USB3 EMCCD Microscope Camera

Andor Technology iXon Ultra 888 EX USB3 EMCCD Microscope Camera

Cambridge ID #: 16874

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, EX2 dual AR coated
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-EX-USB3-EMCCD-Microscope-Camera-16874
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 EXF USB3 EMCCD Microscope Camera

Andor Technology iXon Ultra 888 EXF USB3 EMCCD Microscope Camera

Cambridge ID #: 16881

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, EX2 dual AR coated with fringe suppression
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate:
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-EXF-USB3-EMCCD-Microscope-Camera-16881
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Julabo ED ChillerImage Coming Soon

Julabo ED Chiller

Cambridge ID #: 16553
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Julabo-ED-Chiller-16553
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Julabo FT402 Chiller

Julabo FT402 Chiller

Cambridge ID #: 15552

Immersion Cooler with temperature control for counter-cooling. JULABO immersion coolers are primarily employed for countercooling open bath circulators to ambient temperature or below as well as for rapidly cooling liquids. The models equipped with setpoint control and external Pt100 sensor are capable of maintaining constant temperatures. JULABO immersion coolers have a small footprint and represent an economic solution preventing tap water usage for cooling. Ease of operation make this model series the ideal instruments for a variety of cooling applications.

Specifications:

  • Rapid cooling of liquids to low temperatures
  • Countercooling of liquids in combination with open bath circulators
  • Preventing the use of precious tap water for cooling
  • With PID temperature controller and keypad
  • With Pt100 external sensor, 200 x 6 mm dia., stainless steel
  • Ease of operation
  • Compact design, small footprint
  • Much safer and consistent than dry-ice

 

Learn More
Julabo-FT402-Chiller-15552
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Lauda WK 500 Recirculating Chiller

Lauda WK 500 Recirculating Chiller

Cambridge Scientific ID #'s: 10957, 10958

Features:

  • Circulation chiller
  • 1-line LED display for display of actual or set temperature
  • User-friendly menu guidance with simplest 3-key operation
  • Electronic 2-point temperature control with hysteresis
  • Safety elements for refrigerant pressure, coil temperature. Level indication
  • Powerful pressure pump
  • Programmable switching contact output
  • Filler opening at the front, drain tap
  • Automatic compressor on/off control
  • Air-cooled version

 

Specifications:

  • Working temperature range: 0 °C ... 40 °C
  • Ambient temperature range: 5 °C ... 40 °C
  • Temperature control: ± 0.5 °C
  • Cooling output at 20 °C: 0 kW
  • Pump pressure max: 1.0 bar
  • Pump flow max: 30 L/min
  • Filling volume max: 12 L
  • Overall Dimensions (W x D x H): 350 x 480 x 595 mm
Learn More
Lauda-WK-500-Recirculating-Chiller-10957
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Neslab RTE-211 Refrigerated Circulating WaterbathImage Coming Soon

Neslab RTE-211 Refrigerated Circulating Waterbath

Cambridge ID #: 10568
  • Recirculating Chiller - Refrigerated Bath/Circulator, Temp Ra
  • ng -25° C to +100°C. Bath Volume: 12L/3.2 gal.
  • Learn More
    Neslab-RTE-211-Refrigerated-Circulating-Waterbath-10568
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping