Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Column: 1-15 of 47

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
AB Sciex API 3200 Mass Spectrometer w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS  SystemImage Coming Soon

AB Sciex API 3200 Mass Spectrometer w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14837

Includes Installation and One Year Warranty (Preventative Maintenance at 6 months)

Method Development and Training also Available

 

Includes:

  • AB Sciex API 3200 Mass Spectrometer LC/MS/MS
  • Windows 7 Computer loaded w/ Analyst Software 1.5
  • Turbo V-Spray ESI
  • Vacuum pump
  • Shimadzu Prominence 20 UFLC  Shimadzu
  • Shimadzu DGU-20A3 Degasser
  • (2)Shimadzu LC_20AD Liquid Chromatograph
  • Shimadzu CTO Column Oven
  • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Manuals


The API 3200 LC/MS/MS system is a fully-integrated triple quadrupole mass spectrometer built using premier technology that combines sensitivity and selectivity with ruggedness and reliability, all in an affordable, compact package

  • Innovative Turbo V ion source efficiently ionizes compounds over a wide range of flow rates, virtually eliminating cross-contamination, even with large sample loads
  • Patented LINAC collision cell technology delivers superior MS/MS performance allowing faster scan times without compromising sensitivity or mass spectral quality
  • Simplifies cross-platform methods transfer
  • Gives meaningful results from every experiment

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours and 0.15 Da over 24 hours
  • Mass Range: 5-1,700 (Quad); 50-1,700 (LIT)
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, TripleTrap
Learn More
AB-Sciex-API-3200-Mass-Spectrometer-w--Shimadzu-Prominence-LC-20AD-UFLC-and-CTC-Autosampler-LC-MS-MS--System-14837
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

Cambridge ID #: 14059

Includes 1 year Service Contract, Installation, and a PM at 6 months

 

Includes:

  • AB Sciex API4000 Qtrap LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Rough Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Agilent-1100-HPLC-LC-MS-MS-Q-Trap-System-14059
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

Cambridge ID #: 13945

Includes 1 year Service Contract, Installation, and a PM at 6 months

Method Development and Training also Available

 

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Shimadzu-20AD-UPLC-LC-MS-MS-Q-Trap-System-13945
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14794

Includes 1 year Service Contract, Installation, and a PM at 6 months

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-14794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap LC/MS/MS LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS LC/MS/MS Q Trap System

Cambridge ID #: 15942

Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
    • CTC Autosampler
    • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap™ scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-LC-MS-MS-Q-Trap-System-15942
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System  LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System LC/MS/MS Q Trap System

Cambridge ID #: 14550

 Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap LC/MS/MS
  • Agilent 1200 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quat Pump
    • Agilent G1315D DAD (Diode Array Detector)
  • Solvent Tray
  • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-w--Agilent-1200-HPLC-System-LC-MS-MS-Q-Trap-System-14550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS Q Trap System

Cambridge ID #: 14839

Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
    • CTC Autosampler
    • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap™ scan modes
Learn More
AB-Sciex-API-5500-Qtrap-w--Shimadzu-Prominence-LC-20AD-UFLC-and-CTC-Autosampler-LC-MS-MS-Q-Trap-System-14839
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 9215, 17336, 14782, 14774, 13938, 13993, 15080, 15505, 15630, 14001, 14783, 15290, 15133, 13800, 15627, 16143, 14767, 13908, 15997, 16318

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment---Heater-9215
By clicking below we can further assist you with your inquiry. Inquire 20 In Stock Worldwide Shipping
Agilent 1100 Series - G1316B HPLC Column Compartment / Heater

Agilent 1100 Series - G1316B HPLC Column Compartment / Heater

Cambridge ID #: 14761

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316B-HPLC-Column-Compartment---Heater-14761
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 14763

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications Controller: area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features:  Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:  
    • 1 – 100 μl in 0.1 μl increments
    • Up to 1500 μl with multiple draw (hardware modification required)
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 μl,
    • Typically < 1 % RSD from 1 – 5 μl
  • Sample viscosity range:  0.2 – 5 cp
  • Sample capacity:
    • 2 × well-plates (MTP) + 10 × 2 ml vials
    • 100x2ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically < 30 s using following standard conditions:
    • Default draw speed: 200 μl/min
    • Default eject speed: 200 μl/min
    • Injection volume: 5 μl
  • Carry-over Typically:
    • < 0.01 % using the following conditions:
    • Column: 125 x 4 mm Hypersil ODS, 5 μm
    • Mobile phase: Water/Acetonitrile = 80/20
    • Flow rate: 1 ml/min
    • Injection volume: 1 μl caffeine (1 mg/ml), 5 μl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port

 

Learn More
Agilent-1100-Series---G1367A-HPLC-Well-Plate-Autosampler-14763
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 15934, 16078, 16060, 16141, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-15934
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9592, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Cambridge ID #: 16187

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment---Heater-16187
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367A HPLC Well Plate Autosampler

Agilent 1200 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 16313

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367A-HPLC-Well-Plate-Autosampler-16313
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge ID #: 16300

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-16300
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping