Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

High Throughput Label Free Screening Platform: 1-15 of 271

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

Cambridge ID #: 14059

Includes 1 year Service Contract, Installation, and a PM at 6 months

 

Includes:

  • AB Sciex API4000 Qtrap LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Rough Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Agilent-1100-HPLC-LC-MS-MS-Q-Trap-System-14059
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

Cambridge ID #: 13945

Includes 1 year Service Contract, Installation, and a PM at 6 months

Method Development and Training also Available

 

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Shimadzu-20AD-UPLC-LC-MS-MS-Q-Trap-System-13945
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14794

Includes 1 year Service Contract, Installation, and a PM at 6 months

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-14794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5000 LC/MS/MS  System

AB Sciex API 5000 LC/MS/MS System

Cambridge ID #: 16361

Innovative QJet ion guide technology dramatically improves sensitivity by capturing and focusing more ions generated by the efficient TURBO V ion source. And the TURBO V source virtually eliminates cross-contamination, even with high-concentration samples.  New innovations in sensitivity like QJet ion guide technology make it possible to reach the lowest limits of detection. Combining QJet ion guide technology with the proven TURBO V ion source and a powerful new generation of Analyst software results in a robust, high throughput platform ideal for all phases of pharmaceutical development.

 

Includes:

  • AB Sciex API5000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse-counting channel electron multiplier (CEM) detector
  • Dynamic Range: 1 cps to 4 x 10(6) cps (pulse counting)
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.01% over the entire mass range
  • Mass Range: 5 – 1250 m/z
  • Scan Types:  Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM

 

Learn More
AB-Sciex-API-5000-LC-MS-MS--System-16361
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 15382

Innovative QJet ion guide technology dramatically improves sensitivity by capturing and focusing more ions generated by the efficient TURBO V ion source. And the TURBO V source virtually eliminates cross-contamination, even with high-concentration samples.  New innovations in sensitivity like QJet ion guide technology make it possible to reach the lowest limits of detection. Combining QJet ion guide technology with the proven TURBO V ion source and a powerful new generation of Analyst software results in a robust, high throughput platform ideal for all phases of pharmaceutical development.

 

Includes:

  • AB Sciex API5000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse-counting channel electron multiplier (CEM) detector
  • Dynamic Range: 1 cps to 4 x 10(6) cps (pulse counting)
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.01% over the entire mass range
  • Mass Range: 5 – 1250 m/z
  • Scan Types:  Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Learn More
AB-Sciex-API-5000-LC-MS-MS-Mass-Spectrometer-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-15382
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap LC/MS/MS LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS LC/MS/MS Q Trap System

Cambridge ID #: 15942

Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
    • CTC Autosampler
    • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap™ scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-LC-MS-MS-Q-Trap-System-15942
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System  LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System LC/MS/MS Q Trap System

Cambridge ID #: 14550

 Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap LC/MS/MS
  • Agilent 1200 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quat Pump
    • Agilent G1315D DAD (Diode Array Detector)
  • Solvent Tray
  • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-w--Agilent-1200-HPLC-System-LC-MS-MS-Q-Trap-System-14550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS Q Trap System

Cambridge ID #: 14839

Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
    • CTC Autosampler
    • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap™ scan modes
Learn More
AB-Sciex-API-5500-Qtrap-w--Shimadzu-Prominence-LC-20AD-UFLC-and-CTC-Autosampler-LC-MS-MS-Q-Trap-System-14839
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Advanced Instruments 3900 Osmometer

Advanced Instruments 3900 Osmometer

Cambridge ID #: 10789

The Advanced Instruments Model 3900 Multi-Sample Osmometer determines the osmolality of solutions using freezing point depression (FPD). It is ideal for serum, urine or other bodily fluids in clinical applications, and media or formulations in pharmaceutical, biotech or industrial applications.Automated and multi-sample, it is designed to process a 200-300 μL sample, 90 second test time, and approximately 30 samples per hour. The Model 3900 provides the best accuracy and precision in the market today.

 

  • Sample Volume: 0.2 to 0.3 mL (glass or disposable plastic tubes)
  • Low Range: Less than ±0.5% from a straight line between 0 and 1500 mOsm/kg H2O
  • High Range: Less than ±1.0% from a straight line between 1500 and 4000 mOsm/kg H2O
  • Repeatability: 0 to 400 mOsm: ±2 mOsm/kg H2O (1 S.D.)  400 to 4000 mOsm: ±0.5% (1 S.D.)
  • Drift: Less than 1 mOsm/kg H2O per month
  • Test Time: 90 seconds per sample (typical)
  • Sample throughput: 30 samples per hour at 23ͦ C (73 ͦ C); less in higher ambient  temperature and in high range

 

Performance Over Operating Conditions

 

  • Temperature Effects: Less than 1 mOsm/kg H2O for every 5°C (9°F) ambient temperature change
  • Operating Conditions Temperature:
    • Low Range: 18°C to 35°C (64°F to 95°F)
    • High Range: 18°C to 30°C (64°F to 86°F)
  • Humidity: 5 to 80% relative humidity (non-condensing)
  • Storage Temperature: -40°C to +45°C (-40°F to +113°F)
Learn More
Advanced-Instruments-3900-Osmometer-10789
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Advanced Instruments 3D3 Osmometer

Advanced Instruments 3D3 Osmometer

Cambridge ID #: 8522

Specifications:

  • Electrical
    • Power Requirement: 100 to 130 VAC (60 Hz) or 200 to 250 VAC (50 Hz)
    • Fuses (2): 250V time delay (Type T): 2-Amp (100-130 VAC), 1-Amp (200-250 VAC)
    • Power Consumption: 150 watts
    • Memory Backup: Integral lithium cell; 10 years typical
  • Sample Volume: 0.20 to 0.25 mL
  • Sample Capacity: Single sample
  • Readout: 20-character digital display
  • Units: mOsm/kg H2O
  • Ranges:
    • Low: 0 to 2000 mOsm/kg H2O
    • High: 1400 to 4000 mOsm/kg H2O
  • Resolution: 1 mOsm/kg H2O
  • Communications: DTE RS-232C, parallel printer, barcode
  • Performance at Reference Conditions
    • Linearity: Less than ±0.5% from straight line
    • Repeatability: 0 to 400 mOsm ±2 mOsm/kg (1 S.D.)  400 to 4000 mOsm ±0.5% (1 S.D.)
    • Drift: Less than 1 digit per month
  • Performance Over Reference Conditions
    • Temperature Effect: 1 digit for every 5°C (9°F) ambient temperature change
    • Operating Conditions Temperature:
      • 18°C to 35°C (64°F to 95°F)
      • Humidity: 5 to 80% R.H. (non-condensing)
        • Storage Temperature: - 40°C to +45°C (-40°F to +113°F)
      • Start-up Time: From Stand-By: immediately
      • From Power On: under 5 minutes
      • Test Time: Approximately 2 minutes per sample in 0 to 2000 mOsm range; moderately longer in high range.
      • Dimensions
        • 0 cm x 32.0 cm x 42 cm
        • (11.5" H x 12.5" W x 16.5" D)
        • Height With Head Up: 41 cm (16" H)
      • Weight
        • Net: 12 kg (27 lbs.)
        • Shipping: 18 kg (38 lbs.)
Learn More
Advanced-Instruments-3D3-Osmometer-8522
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Advanced Micro Instruments 3010BR-DC H2S Electrochemical Analyzer

Advanced Micro Instruments 3010BR-DC H2S Electrochemical Analyzer

Cambridge ID #: 15522

Specifications:

  • 4 standard user selectable output ranges to choose from: 0-10ppm, 0-50ppm, 0-100ppm, 0–200ppm
  • Optional output ranges available: 0-500ppm, 0-1000ppm and 2000ppm
  • The selection of an output range simultaneously controls the two alarms, the analog output and the data logger so that all 4 functions operate on the same range
  • Digital display: High resolution 3 ½ digit LCD. Reads full scale from 0.00ppm to 200ppm independently of output range selection and 0.00ppm to 2000ppm when using high range sensor.
  • Alarms: 2 fully adjustable Hydrogen Sulfide (H2S) concentration alarms Dry contacts 5A. @24VDC/115VAC
  • Alarm delays: Programmable from 0-300 minutes
  • Alarm hold off: Programmable from 0-120 minutes
  • Isolated analog output signal: 1-5VDC or 4-20mARepresents the output range selected: 0-10ppm, 0-50ppm, 0-100ppm, 0-200ppm
  • Data logger: Logs data for 15 days @ 1 minute intervals, 30 days @ 2 minute intervals, etc. Represents the output range selected: 0-10ppm, 0-50ppm,0-100ppm,0-200ppm
  • Power requirements: 10-28VDC/ 115VAC<70mA. @ 12VDC non heated<24W @12VDC with heated option
  • Minimum detection: 50ppb of Hydrogen Sulfide (H2S)
  • Repeatability: +/- 1% of range or +/- 0.2ppm of H2S,whichever is greater
  • Operating temperature range: 25 to 115Ëš F non-heated; -20 to 115Ëš F heated option
  • Diurnal temperature specification:< +/- 2 % of scale over temperature range
  • 90% full scale response times for specified range: 0-100ppm < 120 seconds @ 1.5SCFH; 0-2000ppm < 120 seconds @ 1.5SCFH
  • Response to Methyl Mercaptan: 40% of actual concentration
  • Response to Sulfur Dioxide: 18% of actual concentration
  • Area Classification: CSA approved to UL-913 and UL-1203 Class 1, Div. 1, Groups B,C,D with a flammable gas sample
  • Inlet gas pressure: 0.5 to 150psig
  • Gas connections: ¼" 316 S.S. compression fittings
  • Wetted parts: 316 S.S. fittings, electroless nickel plated cellblock, gold plated contacts, acrylic flow meter and Viton O-rings
  • Recommended flow rate: from 1.0 to 1.5 SCFH
  • Mounting: Wall mount or 2.0" pipe
  • Dimensions: 13.0"W x 9.5"H x 5.0"D
  • Weight: 16 lbs.
Learn More
Advanced-Micro-Instruments-3010BR-DC-H2S-Electrochemical-Analyzer-15522
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 14613, 16067, 16337, 9165, 16061, 16848, 17332, 15359, 13906, 12097, 14496, 15507, 16000, 16142

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-14613
By clicking below we can further assist you with your inquiry. Inquire 14 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge ID #: 16347

Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve.
Specifications:

  • Setable Flow: 001 – 10 ml/min, in 0.001 ml/min increments
  • Flow Precision: £ 0.07% RSD, or £ 0.02 min SD whatever is greater, based on retention time at constant room temperature
  • Flow Accuracy: ± 1% or 10 µl/min whatever is greater
  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min
  • Pressure: Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min
  • Pressure Pulsation: pulsation < 2 % amplitude (typically < 1 %), at 1 ml/min is opropanol, at all pressures > 1 MPa (10 bar)
  • Recommended pH:0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure
  • Composition Range: 0 – 95 % or 5 – 100 %, user selectable
  • Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-16347
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 12471, 16041, 13408, 16314, 16001, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping