We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Solvent Delivery Module: 1-15 of 39

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System  LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System LC/MS/MS Q Trap System

Cambridge ID #: 14550

 Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap LC/MS/MS
  • Agilent 1200 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quat Pump
    • Agilent G1315D DAD (Diode Array Detector)
  • Solvent Tray
  • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-w--Agilent-1200-HPLC-System-LC-MS-MS-Q-Trap-System-14550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 14613, 17968, 9165, 16848, 17332, 13906, 17965, 14496, 15507

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-14613
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Cambridge ID #: 17963

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment---Heater-17963
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1322A HPLC Degasser

Agilent 1100 Series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 15233, 15935, 13139, 13931, 16339, 15230, 17334, 15628, 15996, 17975, 15083, 15705, 14953, 17973

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1100-Series---G1322A-HPLC-Degasser-15233
By clicking below we can further assist you with your inquiry. Inquire 14 In Stock Worldwide Shipping
Agilent 1100 Series - Solvent Tray HPLC Solvent TrayImage Coming Soon

Agilent 1100 Series - Solvent Tray HPLC Solvent Tray

Cambridge ID #: 7147

Agilent 1100 HPLC Solvent Tray for HPLC Systems used to hold containers and organize solvent lines

Learn More
Agilent-1100-Series---Solvent-Tray-HPLC-Solvent-Tray-7147
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G1322A HPLC Degasser

Agilent 1200 series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 16301, 16328

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1200-series---G1322A-HPLC-Degasser-16301
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Cambridge ID #: 16349

Features:

  • Advanced temperature controlled detector optics ready to use within two hours of installation
  • Automatic zero and automatic purge combined with a recycle valve for automatic solvent recycling allow uninterrupted operation
  • Automatic light intensity control circuit to ensure the optimum performance of the optics
  • Integrated diagnostics for efficient troubleshooting
  • Built-in refractive index calibration
  • Front access to valves and capillaries for easy maintenance
  •  

Specifications:

  • Detection type: Refractive Index
  • Refractive index range: 1.00 – 1.75 RIU, calibrated
  • Measurement range: +/- 600 x 10-6 RIU
  • Optics temperature control: 5 ° C above ambient to 55 ° C
  • Sample cell volume: 8uL
  • Maximum pressure: 5 bar (0.5Mpa)
  • Maximum flow rate: 5mL/minute
  • Valves: Automatic purge and automatic solvent recycle
  • Volumes: Inlet port to sample cell 62uL, inlet port to outlet port 590uL
Learn More
Agilent-1200-Series---G1362A-HPLC-Refractive-Index-Detector-16349
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - HPLC Stack HPLC System

Agilent 1200 Series - HPLC Stack HPLC System

Cambridge ID #: 9593

Includes:

  • Agilent G1322A Degasser
  • Agilent G1311A Quat Pump
  • Agilent G1329A Autosampler
  • Agilent G1330A Autosampler Chiller
  • Agilent G1365D DAD (Diode Array Detector)
  • Agilent G1316A Column Compartment
  • Solvent Tray
  • Computer Loaded with ChemStation
  • Cables and Manuals
Learn More
Agilent-1200-Series---HPLC-Stack-HPLC-System-9593
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Series - G1310B HPLC Isocratic Pump

Agilent 1260 Series - G1310B HPLC Isocratic Pump

Cambridge ID #: 17964

The Agilent Technologies 1200 Series (G1310B) 1260 Infinity Isocratic Pump is a HPLC workhorse for demanding QA/QC and routine applications, designed to provide virtually pulse-free and stable solvent flow. This delivery principle allows variable stroke volume optimized to selected flow rate. The broadened pressure range with maximum pressure of 600 bar allows the use of small particle size columns, longer columns, or alternative solvents of higher viscosity. Additionally, the G1310B is the ideal pump for GPC/SEC applications where run-to-run and day-to-day precision of retention times are important.

 

Specifications:

  • Settable flow range: set points 0.001 - 5 mL/min, in 0.001 mL/min increments
  • Flow range: 0.2 to 10.0 mL/min
  • Flow precision: ≤ 0.07 % RSD or ≤ 0.02 min SD
  • Flow accuracy: ± 1 % or 10 μL/min whatever is greater, pumping degassed H2O at 10 MPa (100 bar)
  • Pressure operating range:
    • Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 mL/min
    • Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 mL/min
Learn More
Agilent-1260-Series---G1310B-HPLC-Isocratic-Pump-17964
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G4220A HPLC Binary PumpImage Coming Soon

Agilent 1290 Series - G4220A HPLC Binary Pump

Cambridge ID #: 17710

Features:

The Binary pump is designed for highest performance, GLP compliance and easy maintenance.

It includes the following features:

• Seal wash for continued high lifetime of pump seals for buffer applications.

• Solvent selection valve for method flexibility.

• Jet Weaver for optimum mixing performance with a minimum of delay volume.

• Automatic purge function for ease of use and unattended preparation of the system.

• Auto tuning of the delivery cycle for compensation of elasticity and solvent volume change effects (compressibility, thermal expansion, mixing contraction).

• Solvent selection for optimum flow and composition accuracy.

• Fast defill function for improved intake and delivery performance.

• Two pistons in series design for increased reliability.

• High resolution piston movement control for smooth and reliable motion.

Specifications:

  • Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
  • Settable flow range:  Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
  • Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
  • Flow accuracy:  ±1 % or 10 µl/min, whatever is greater.
  • Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.
  • Pressure pulsation:  <1% amplitude or < 0.5 MPa (5 bar), whatever is greater.
  • Compressibility compensation: Automatic, pre-defined, based on mobile phase selection.
  • Gradient formation: High pressure binary mixing
  • Delay volume: 
    • Jet Weaver V35: <45 µl
    • Jet Weaver V100: <75 µl
  • Composition range Settable range: 0 - 100 %
  • Composition precision: <0.15 % RSD, or 0.01 min SD, whatever is greater
  • Composition accuracy: ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min)
Learn More
Agilent-1290-Series---G4220A-HPLC-Binary-Pump-17710
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890N Gas Chromatography

Agilent 6890N Gas Chromatography

Cambridge Scientific ID #'s: 15694, 15691

The Agilent/HP 6890N GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. EPC reduces re-calibration frequency and improves laboratory productivity. Designed to work seamlessly with the 6890N, the included 7683 Autosampler connects without a controller box or multiple power cords/outlets, and is packed with features including Agilent’s fast-injection technology.

 

Includes:

  • FID Detectors (Flame Ionization Detectors) OPtional
  • 7683 Autosampler (100 Vial Capacity)
  • Computer Loaded with Chemstation Software
  • Manuals and Cables

 

Features:

  • Electronic Pressure Control on detector and injector
  • Ambient temperature +4 °C to 450 °C
  • Temperature set point resolution: 1 °C
  • Supports 6 oven ramps with 7 plateaus, Negative ramps are allowed
  • Overview: Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
  • Accomplish more with networking abilities
    • Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
    • Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
  • Increased Laboratory Efficiency: Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
  • Decreased Calibration Time: You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
  • High Sample Throughput: The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
  • Minimal Rework: The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

 

Specifications:

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
  • Height: 50 cm (19.7 in.)
  • Width: 58 cm (26.8 in.)
  • Depth: 54 cm (21.6 in.)
  • Average Weight: 49 kg (108 lb)
  • Networkable: Yes
  • Ambient Operating Temperature: 15 ËšC to 35 ËšC
  • Ambient Operating Humidity: 5-95 %
  • Storage Extremes: -40ËšC to 65Ëš
  • Line Voltage Requirements: ±5% of nominal
  • Dimensions: 28 x 31 x 16 cm
  • Operating temperature: 4ËšC above ambient to 450ËšC
  • Maximum run time: 120ËšC/min
Learn More
Agilent-6890N-Gas-Chromatography-15694
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Amersham Biosciences GE AKTA Explorer FPLC System

Amersham Biosciences GE AKTA Explorer FPLC System

Cambridge ID #: 13731

AKTA Explorer is designed for scouting, development and optimization of methods for all chromatographic techniques.  Flexibility and high levels of automation in combination with reproducibility and reliable operation make it an excellent choice for laboratories involved in method and process development.

 

Features:

  • Box 900: Storage compartment and Solvent Tray
  • P-950 sample pump
  • UV-900
  • pH/C-900: pH and Conductivity Detector
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • P-900 Series Gradient Pump
  • Frac 950 Fraction Collector
  • CU-950: Communications Module
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
Learn More
Amersham-Biosciences-GE-AKTA-Explorer-FPLC-System-13731
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE AKTA Explorer 100 FPLC System

Amersham Biosciences GE AKTA Explorer 100 FPLC System

Cambridge ID #: 10602

AKTA Explorer is designed for scouting, development and optimization of methods for all chromatographic techniques.  Flexibility and high levels of automation in combination with reproducibility and reliable operation make it an excellent choice for laboratories involved in method and process development.

 

Features:

  • Box 900: Storage compartment and Solvent Tray
  • P-950 sample pump
  • UV-900
  • pH/C-900: pH and Conductivity Detector
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • P-900 Series Gradient Pump
  • Frac 950 Fraction Collector
  • CU-950: Communications Module
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
Learn More
Amersham-Biosciences-GE-AKTA-Explorer-100-FPLC-System-10602
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE AKTA FPLC FPLC System

Amersham Biosciences GE AKTA FPLC FPLC System

Cambridge Scientific ID #'s: 10822, 10569, 10823, 16947, 16751, 9867

AKTA FPLC system is a fully automated liquid chromatography system designed for research scale purification of proteins, wherein proteins of various sizes can be readily purified using different kinds of columns.

 

Features:

  • P-920 Pump
  • UPC-900
  • Frac-900 Fraction Collector
  • INV-907 Injection Valve
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • Box 900: Storage compartment and Solvent Tray
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
  • Manuals
Learn More
Amersham-Biosciences-GE-AKTA-FPLC-FPLC-System-10822
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Amersham Biosciences GE AKTA Purifier FPLC System

Amersham Biosciences GE AKTA Purifier FPLC System

Cambridge Scientific ID #'s: 14009, 14179, 14258

Purification can be performed at microgram, milligram or gram scale, depending on the core system and kits selected.

 

Features:

  • Box 900: Storage compartment and Solvent Tray
  • CU-950: Communications Module
  • P-950 sample pump
  • P-900: System Pump Model with Four Pump Heads in Two Pump Modules
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • UV-900: Variable, Multiwavelength UV-Vis detector
  • pH/C-900: pH and Conductivity Detector
  • Frac-920: Fraction Collector
  • Model INV-907: Injection Valve
  • Model PV-908: Sample Outlet Valve, For Sample Collection, with 8 ports
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
Learn More
Amersham-Biosciences-GE-AKTA-Purifier-FPLC-System-14009
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping