Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Spectrometers / Spectrophotometers ranging from Spectrofluorometer, Fluorescence, Atomic Absorption (AA), ICP, to UV / Vis / NIR Spectrometers and Microplate. Some of our popular manufacturers include Beckman, Perkin Elmer, HP, Hitachi, Varian and Bio-Tek. We have one of the largest inventories of Mass Spectrometers available. We also offer service contracts, installation and training. Browse our inventory of used mass spec products below.

Spectrophotometer Uv/vis Reader: 1-15 of 16

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Amersham Biosciences GE Ultrospec 2100 Pro Spectrophotometer UV/Vis Reader

Amersham Biosciences GE Ultrospec 2100 Pro Spectrophotometer UV/Vis Reader

Cambridge ID #: 18078

Simple to use instrument for measuring absorbance and concentration. It provides stored routines for nucleic acid quantitation and also a standard curve routine for protein determination. Wavelength scan with zoom, absorbance changes with time, reaction rate determinations, and standard curves can be displayed and printed out. User defined equations can be entered using the multi-wavelength mode and up to 18 methods can be saved. Ultrospec 2100 Pro is a versatile and reliable instrument for use in any laboratory.

Specifications:

 

  • Temperature Range: 10°C to 40°C
  • Wavelength: 190-900 nm
  • Light Source: Xenon Lamp
  • Monochromator: 1200 lines/mm aberration corrected concave grating
  • Detection Technology: Two Silicon Photodiodes
  • Spectral Bandwidth: <3 nm
  • Photometric Reproducibility: Within 0.5% of absorbance value to 3.000 A at 546 nm
  • Photometric Min: -3.000 A (0.01 concentration units, 0.1% T)
  • Stability: ± 0.001 A per hour at 340 nm at 0 A
  • Accuracy: ± 1nm 
Learn More
Amersham-Biosciences-GE-Ultrospec-2100-Pro-Spectrophotometer-UV-Vis-Reader-18078
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE Ultrospec 500 Pro Spectrophotometer UV/Vis Reader

Amersham Biosciences GE Ultrospec 500 Pro Spectrophotometer UV/Vis Reader

Cambridge Scientific ID #'s: 12634, 12636, 12635

The Ultrospec 500 pro Visible Spectrophotometer is an easy to use instrument optimized for both the biological science teaching laboratory and general biological science laboratory. In addition to the basic modes of operation, Ultrospec 500 pro has enhanced software and method storage functionality, with menu options that can be password-protected, if required.

Specifications:

  • Wavelength Range: 325 – 900 nm
  • Monochromator: Plane grating with 1200 lines/mm
  • Spectral Bandwidth: 5 nm
  • Wavelength Accuracy: +/- 2nm
  • Wavelength Accuracy: +/- 0.5 nm
  • Photometric Range: -0.300 – 3.000A
  • Photometric Linearity: +/- 0.5%
  • Photometric Reproducibility: 5%
  • Dimensions: 300 x 400 x 190 mm
  • Weight: 6 kg
  • Power Requirements: 90 – 265V, 50/60Hz, 100VA
Learn More
Amersham-Biosciences-GE-Ultrospec-500-Pro-Spectrophotometer-UV-Vis-Reader-12634
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Beckman Coulter DU 64 Spectrophotometer UV/Vis ReaderImage Coming Soon

Beckman Coulter DU 64 Spectrophotometer UV/Vis Reader

Cambridge ID #: 4156
  • Spectrophotometer. Wavelength: 200 to 900 nm
  • Learn More
    Beckman-Coulter-DU-64-Spectrophotometer-UV-Vis-Reader-4156
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Beckman Coulter DU 640 Spectrophotometer UV/Vis Reader

    Beckman Coulter DU 640 Spectrophotometer UV/Vis Reader

    Cambridge Scientific ID #'s: 3260, 6271, 13440, 8354, 6917, 9983

    Features:

    • Single-beam, microprocessor-controlled
    • Measurements in the UV-VIS range, operates in the wavelength range of 190-1100 nm
    • Provides fixed wavelength, wavelength scan, and kenetics/time as standard modes. Features:
    • Wavelenght accuracy: +/- 0.2nm
    • Photometric readout: (-0.300) -3.000A / 0.0-200.0%T
    • Bandpass: 1.8 nm
    • Scan speed: 120, 240, 600, 1200, 2400 nm/min,

    Includes:

    • Monitor
    • Keyboard
    • Mouse
    Learn More
    Beckman-Coulter-DU-640-Spectrophotometer-UV-Vis-Reader-3260
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Beckman Coulter DU 650 Spectrophotometer UV/Vis Reader

    Beckman Coulter DU 650 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 9156

    Features:

    • Wavelength Range: 190 to 1100
    • Wavelength Setability: 0.1 nm increments
    • Wavelength Accuracy: ± 0.2 nm (at D, peak 656.1 nm)
    • Wavelength Repeatability: ± 0.1 nm (at 1)--, peak 656.1 nm)
    • Spectral Bandwidth: 1.8 nm
    • Photometric Readout: - 0.300 to 3.000 A or 0.010 200.0 %T
    • Photometric Accuracy: ± 0.005 A (at 1 A with N1ST 930D solid filter at 546 nm)
    • RMS Noise: < 0.0002 A RMS (OA, average readings at 500 nm)
    • Stray Light: ± 0.001 A (from 220 to 800 nm, at OA)
    • Scanning Speeds: 120. 240, 600, 1200, 2400 nm/minute.
    • Data Collection Rate: 20 samplings/second

     

    Specifications:

    • Width: 69 cm (27 in)
    • Height: 61 cm (24 in)
    • Depth: 53 cm (21 in)
    • Weight: 37 kg (81 lbs)
    • Line Voltage: 100/120V ± 10% or 220/240V ± 10%
    • Frequency: 50/60 Hz
    • Power: 200 watts typical
    • Temperature Operating Range: +15°C to 40°C (59°F to 104°F)
    • Humidity: < 85% maximum relative humidity, not to exceed 32.5°C WBT

     

    Learn More
    Beckman-Coulter-DU-650-Spectrophotometer-UV-Vis-Reader-9156
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Bio-Rad Smartspec 3000 Spectrophotometer UV/Vis Reader

    Bio-Rad Smartspec 3000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 9216

    Specifications:

    • Wavelength Range: UV and Visible ranges 200 to 800 nm
    • Wavelength accuracy: (+/-) 2 nm
    • Spectral bandwidth: 5nm
    • Light source: Xenon flash lamp
    • Detector: Photodiode array
    • Number of cuvettes: one Size of cuvettes 100 µl, 700 µl, 1.5 ml, 3.5 ml
    • Pathlength: 1 mm, 2 mm, 5 mm and 10 mm
    • Display: 2 x 24 alphanumeric built-in backlit LCD display
    • Printer: Built-in alphanumeric/graphic
    • Interface: RS-232 serial port
    • Scan speed: 200–800 nm in 20 seconds max
    • Dimensions: 33cm(W)x26cm(D)x14cm(H)
    Learn More
    Bio-Rad-Smartspec-3000-Spectrophotometer-UV-Vis-Reader-9216
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Eppendorf Biophotometer Spectrophotometer UV/Vis Reader

    Eppendorf Biophotometer Spectrophotometer UV/Vis Reader

    Cambridge Scientific ID #'s: 12243, 12066, 11707

     

    State-of-the-art technology with an easy-to-use format in a compact footprint: that is the Eppendorf BioPhotometer! It's large key pads, pre-programmed methods, and pre-set wavelengths and conversion factors greatly simplify the sample quantification. The large LCD screen displays the sample concentrations, absorption values, OD260/OD230 and OD260/OD230 and sample dilutions at a glance.

     

    Features:

    • Compact design, easy to transport
    • Robust housing, splash- and water-resistant
    • High-value components guarantee high operating safety
    • Metal housing ensures high stability
    • Xenon flash lamp source with extremely long service life
    • Ready to measure immediately (no warmup time)
    • Self-explanatory, extremely simple operation
    • Measurement only takes approx 2 seconds
    • Programmed methods: ssDNA, dsDNA, RNA, Oligo, Protein, Lowry/Lowry micro, Bradford/Bradford micro, BCA/BCA micro, and OD 600
    • Optional background correction at 320 nm for UV methods
    • Automatic calculation of sample dilution
    • Simple conversion using the "Conversion" key
    • Up to 10 standards for colorimetric analyses
    • Storage of the last 100 results and all corresponding data
    • Storage of all calibrations
    • Sample data and calibration data can be called up after being stored

     

    Specifications:

     

    • Optical system:  Absorption, single-beam photometer with reference beam
    • Light source: Xenon flash lamp
    • Light beam height: 8.5 mm
    • Spectral range:  220 to 750 nm
    • Wavelengths: Xe 230; 260; 280; 320; 562; 595 nm
    • Spectral range width: 5 nm: 230 to 320 nm; 7 nm: 562 to 595 nm
    • Photometric measuring range: 0,000 to 3,000 A
    • Photometric accuracy: ±1% at 1 A
    • Photometric precision: < 0.5% at 1 A
    • Method-dependent evaluation:    - Absorbance/concentration using factor
      • Concentration using calibration with 1 to 10 standards
      • One-point calibration (1 std) / linear regression (2 to 10 standards)
      • Non-linear regression (polynom, 3rd degree; 4 or 5 standards), 1x, 2x or 3x determination
      • Ratio 260/280, ratio 260/230, molar concentration, total yield
      • Warburg formula for protein direct A280
    • Calibration memory: For protein methods
    • Results memory: For 100 results with absorbance, ratio values, sample no., dilution, date and time
    • Printer interface: RS-232C, serial, for printer or PC with BioPhotometer software package
    • Power consumption: Approx. 20 W in operation; 10 W in standby mode
    • Cuvettes: UVette and common rectangular cuvettes of suitable glass or plastic materials
    Learn More
    Eppendorf-Biophotometer-Spectrophotometer-UV-Vis-Reader-12243
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    GE Healthcare Ultrospec 7000 Spectrophotometer UV/Vis Reader

    GE Healthcare Ultrospec 7000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 12645

    Includes:  Test Tube Holder 1 80-7100-11

     

    Ultrospec 7000 is a multiple application, dual-beam, UV Visible spectrophotometer developed to meet the day-to- day needs of the busy laboratory. Engineered for robust, lower cost operation with minimal maintenance requirements, yet providing simple, touchscreen operation, multiple-user profiles

    and a choice of data export methods. A range of software upgrade and accessory options are available to meet your needs in the future

     

    Technical specification:

    • Optical system: Double-beam monochromator
    • Detector: Dual-silicon photodiodes
    • Light source: Pulsed Xenon lamp
    • Wavelength calibration: Automatic upon switch on
    • Wavelength range: 190 – 1100 nm
    • Absorbance range: - 4.0 to 4.0 A
    • Spectral bandwidth: 2 nm
    • Stray light: < 0.05%T at 220 nm using NaI and 340 nm using NaNO2
    • Wavelength accuracy: ± 0.5 nm across wavelength range
    • Wavelength reproducibility: ± 0.1 nm
    • Photometric reproducibility: ± 0.002 A at 1 A
    • Photometric accuracy:
      • ± 0.002 A at 0.5 A, ± 0.004 A at 1 A,
      • ± 0.006 A at 2 A
    • Zero stability: ± 0.001 A/hr at 500 nm
    • Noise: < 0.0002 A RMS at 500 nm
    • Outputs: USB cable, USB memory stick,
    • Power supply: 90-250 V, 50/60 Hz, Max 30 VA
    • Dimensions (w×d×h): 533 mm × 457 mm × 330 mm
    • Weight: < 18 kg
    Learn More
    GE-Healthcare-Ultrospec-7000-Spectrophotometer-UV-Vis-Reader-12645
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Milton Roy Spectronic 21D Spectrophotometer UV/Vis Reader

    Milton Roy Spectronic 21D Spectrophotometer UV/Vis Reader

    Cambridge ID #: 12631

    Spectronic 21 Digital Model with UV Capabilities features linear digital readouts in % T, A, and concentration; push-button decimal selection; and an RS-232 interface port. Three-position sensitivity switch and the 100% T/zero A control let you select desired instrument gain setting. Digital display alerts you to out-of-range conditions.

     

    Spectrophotometer includes a universal test tube/cuvette holder (accepts 10- to 26-mm pathlength test tubes or 1- to 10-mm pathlength rectangular cuvettes), twelve 10-mm pathlength test tube cuvettes, spare tungsten lamp, occluder block, operating manual, dust cover, and 3-ft cord with U.S. standard plug.

     

    Specifications:

    • Bandwidth: 10 nm
    • Wavelength range: 200 to 1000 nm
    • Wavelength accuracy: >2 nm at 254, 365, and 546 nm
    • Photometric range: Transmittance: 00.0 to 100.0% T
    • Absorbance: 0.000 to 1.990 A
    • Concentration: 000 to 1990 C
    • Detector: Solid-state silicon
    • Output: 0 to 1.0 VDC; RS-232
    • Stray light: 0.05%T at 340 nm
    • Model: SPECTRONIC 21
    • Source lamp: Tungsten/deuterium
    • Display: 3-1/2-digit LED, 7/16" H
    Learn More
    Milton-Roy-Spectronic-21D-Spectrophotometer-UV-Vis-Reader-12631
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Perkin Elmer Lambda 25 Spectrophotometer UV/Vis Reader

    Perkin Elmer Lambda 25 Spectrophotometer UV/Vis Reader

    Cambridge Scientific ID #'s: 16946, 11107

    Versatile spectrometers operating in the ultraviolet (UV) and visible (Vis) spectral ranges. Optical components are coated with silica for durability and holographic grating is used in the monochromator. Features a double-beam, all-reflecting system, usable for a wide range of applications.

     

    Includes:

    • Computer loaded w/ software
    • 6 cell Cuvette Holder
    • Peltier Port

    Modes Of Operation:

    • Scanning
    • Wavelength program
    • Time-drive
    • Rate
    • Quant
    • Scanning quant

    Features:

    • True double-beam operation
    • High throughput, low stray-light optics
    • Pre-aligned deuterium and tungsten-halogen lamps
    • Wide range of accessories and consumables

    Benefits:

    • Very high stability, high accuracy and reproducibility.
    • Easily passes all pharmacopoeia and regulatory performance tests
    • Quickly replaced for minimal downtime
    • Perfect for any liquid sample
    • Select the version that best matches your analysis needs and the skill level of your operators

    Applications:

    • Routine UV/ Vis Testing
    • Liquids Analysis
    • Solids, Pastes, and Powder Samples
    • Regulatory Tests requiring variable bandwidths

    Specifications:

    • Temperature Range: Ambient 15ºC to 35ºC
    • Relative Humidity: 20% to 80% (without condensation)
    • Dimensions: 650 x  560 x 260 nm (W x D x H)
    • Wavelength Range: 190 nm to 1100 nm
    • Wavelength Accuracy: ±0.1 nm
    • Wavelength Reproducibility: ±0.1 nm
    • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
    • Beam Center Height: 15 mm
    • Optical Path Length: 121 mm
    • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
    • Photometric Range: 0% to 100%
    • Detector: Photodiodes
    • Grating: Holographic, 1053 lines/mm
    • Lamp Change: Automatically at 326 nm
    • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
    • Digital Port: One RS 232 C Interface
    • Type: Scanning Double-Beam
    • Pollution Degree: 2
    • Altitude: Up to 2000 m
    Learn More
    Perkin-Elmer-Lambda-25-Spectrophotometer-UV-Vis-Reader-16946
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Perkin Elmer Lambda 35 Spectrophotometer UV/Vis Reader

    Perkin Elmer Lambda 35 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 15568

    Versatile spectrometers operating in the ultraviolet (UV) and visible (Vis) spectral ranges. Optical components are coated with silica for durability and holographic grating is used in the monochromator. Features a double-beam, all-reflecting system, usable for a wide range of applications.

     

    Includes:

    • Computer loaded w/ software
    • 6 cell Cuvette Holder
    • Peltier Port

    Modes Of Operation:

    • Scanning
    • Wavelength program
    • Time-drive
    • Rate
    • Quant
    • Scanning quant

    Features:

    • True double-beam operation
    • High throughput, low stray-light optics
    • Pre-aligned deuterium and tungsten-halogen lamps
    • Wide range of accessories and consumables

    Benefits:

    • Very high stability, high accuracy and reproducibility.
    • Easily passes all pharmacopoeia and regulatory performance tests
    • Quickly replaced for minimal downtime
    • Perfect for any liquid sample
    • Select the version that best matches your analysis needs and the skill level of your operators

    Applications:

    • Routine UV/ Vis Testing
    • Liquids Analysis
    • Solids, Pastes, and Powder Samples
    • Regulatory Tests requiring variable bandwidths

    Specifications:

    • Temperature Range: Ambient 15ºC to 35ºC
    • Relative Humidity: 20% to 80% (without condensation)
    • Dimensions: 650 x  560 x 260 nm (W x D x H)
    • Wavelength Range: 190 nm to 1100 nm
    • Wavelength Accuracy: ±0.1 nm
    • Wavelength Reproducibility: ±0.1 nm
    • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
    • Beam Center Height: 15 mm
    • Optical Path Length: 121 mm
    • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
    • Photometric Range: 0% to 100%
    • Detector: Photodiodes
    • Grating: Holographic, 1053 lines/mm
    • Lamp Change: Automatically at 326 nm
    • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
    • Digital Port: One RS 232 C Interface
    • Type: Scanning Double-Beam
    • Pollution Degree: 2
    • Altitude: Up to 2000 m
    Learn More
    Perkin-Elmer-Lambda-35-Spectrophotometer-UV-Vis-Reader-15568
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Perkin Elmer Lambda 40 Spectrophotometer UV/Vis Reader

    Perkin Elmer Lambda 40 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 16658

    Versatile spectrometers intended for routine ultraviolet (UV) and visible (Vis) analysis. Featuring a double-beam, all-reflecting system, usable for a wide range of applications.

     

    Specifications:

     

    • Temperature Range: Ambient 15ºC to 35ºC
    • Relative Humidity: 20% to 80% (without condensation)
    • Dimensions: 650 x  560 x 260 nm (W x D x H)
    • Wavelength Range: 190 nm to 1100 nm
    • Wavelength Accuracy: ±0.3 nm
    • Wavelength Reproducibility: ±0.1 nm
    • Spectral Bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm
    • Beam Center Height: 15 mm
    • Optical Path Length: 121 mm
    • Scan Speeds (nm/min): 7.5, 15, 30 , 60, 120, 240, 480, 960, 1920 and 2880
    • Photometric Range: 0% to 100%
    • Detector: Photodiodes
    • Grating: Holographic, 1053 lines/mm
    • Lamp Change: Automatically at 326 nm
    • Radiation Sources: Pre-Aligned Deuterium and Halogen Lamps
    • Digital Port: One RS 232 C Interface
    • Type: Scanning Double-Beam
    • Pollution Degree: 2
    • Altitude: Up to 2000 m
    Learn More
    Perkin-Elmer-Lambda-40-Spectrophotometer-UV-Vis-Reader-16658
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Shimadzu UVmini-1240 Spectrophotometer UV/Vis ReaderImage Coming Soon

    Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 18159

    Specifications:

     

    Site Requirements

    • Dimensions (W x D x H): 416 × 379 × 274mm
    • Weight: 11 kg
    • Ambient temperature: 15 to 35°C
    • Ambient humidity: 45 to 80%, less than 70% if over 30°C
    • Power supply: 100~120 V 50/60 Hz 160 VA ; 220~240 V 50/60 Hz 160 VA

    Performance Specifications:

    • Spectrum bandwidth: 5 nm
    • Wavelength accuracy: ± 1.0 nm
    • Wavelength repeatability: ± 0.3 nm
    • Stray light: less than 0.05% (220.0 nm Nal, 340.0 nm NaNO2 & UV39)
    • Photometric range: −3.99 to 3.99 Abs (absorbance) ;  0.0 to 200% (transmittance)
    • Recording range: −3.99 to 3.99 Abs (absorbance) ;  −399 to 399% (transmittance)
    • Photometric accuracy: ± 0.005 Abs (at 1.0 Abs) ; ± 0.003 Abs (at 0.5 Abs)
    • Photometric repeatability: ± 0.002 Abs (at 1.0 Abs)
    • Drift: less than ± 0.001 Abs/h (after 2 hr warm-up)
    • Baseline flatness: ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm)
    • Noise: less than 0.002 Abs, Peak to Peak / less than 0.0005 Abs, RMS

    Optical Design

    • Wavelength range: 190.0 to 1100.0 nm
    • Display wavelength: 0.1nm step
    • Selectable wavelength: 0.1 nm step (1 nm step in spectrum mode)
    • Scan speed: ± 3800 nm/min (wavelength change) ; ± 24 to 1400 nm/min (scan)
    • Light source change: Auto change with wavelength ; halogen lamp only ; deuterium (D2) lamp only
    • Measurement method: single beam measurement
    • Monochromator: incorporates aberration-corrected concave blazed holographic grating
    • Detector: silicon photodiode
    Learn More
    Shimadzu-UVmini-1240-Spectrophotometer-UV-Vis-Reader-18159
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Forma Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Thermo Forma Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 17429

    Features:

    Enhance the limit of detection for DNA, RNA and protein with the Thermo Scientific NanoDrop 2000c UV-Vis spectrophotometer featuring both microvolume pedestal and cuvette measurement options. The cuvette station is ideal for measuring dilute nucleic acid and protein assays, includes heating and microstirring capabilities, and allows users to perform kinetics and cell culture readings (600nm).

    • Wide spectral range (190-840nm) for measuring a variety of samples types:
      • Peptides (205nm)
      • DNA and RNA (260nm)
      • Purified protein (280nm)
      • Toxicology assays and industrial dyes (490nm)
      • Gold nanoparticles (520nm)
      • Colorimetric protein assays (BCA 562nm, Bradford 595nm, Modified Lowry 650nm, Pierce 660 660nm)
      • Optical Density measurements (600nm)
    • Combining the patented sample retention system with cuvette capability accommodates low and high concentrations
      (0.4 to 15,000 ng/µL dsDNA and 0.01 – 400 mg/mL BSA)
    • Pedestal measurements that require only 0.5 – 2 µL of your sample and do not require sample dilution, even for highly concentrated samples
    • Calculates sample purity ratios (260/280 nm and 260/230 nm)
    • Pre-configured methods for DNA, Protein A280, Microarray, Protein and Labels, Pierce 660, Bradford, BCA, and Lowry
    • Fast measurement time of less than 5 seconds, 10 -15 seconds from sample pipette to wipe
    • User-friendly software that includes custom methods and data export capabilities

    Nanodrop 2000C Specifications:

    • Instrument Type: Spectrophotometer  
    • Minimum Sample Volume: 0.5 µl
    • Recommended Sample Volume, Nucleic acid: 1 µl
    • Recommended Sample Volume, Proteins: 2 µl
    • Sample Number: 1
    • Path Length: 1 mm (auto-ranging to 0.05 mm)
    • Light Source(s): Xenon flash lamp
    • Detector Type: 2048 - element linear silicon CCD array
    • Wavelength Range: 190 - 840 nm
    • Wavelength Accuracy: 1 nm
    • Spectral Resolution: ≤ 1.8 nm (FWHM at Hg 253.7 nm)
    • Absorbance Precision: 0.002 (1 mm path)
    • Absorbance Accuracy: 3% (at 0.74 at 350 nm)
    • Absorbance Range: 0.04 - 300 (10 mm equivalent)
    • Detection Limit: 2 ng/µl (dsDNA)
    • Maximum Concentration: 15,000 ng/µl (dsDNA)
    • Measurement Time: 5s (typical)
    • Footprint: 14 x 20 cm
    • Weight: 2.1 kg
    • Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
    • Operating Voltage: 12 vdc
    • Operating Power Consumption: 12 - 18 W (max 30 W)
    • Standby Power Consumption: 5 W
    • Software Compatibility: Operating software for the NanoDrop 2000 and NanoDrop 2000c. Compatible with Professional versions of Windows 8.1 (64 bit), and Windows 7 (32 and 64 bit).    

    Cuvette Specifications:   

    • Z-Height: 8.5 mm
    • Heating: 37 ± 0.5 °C
    • Stirrer: 150-850 rpm
    • Path Length: 10, 5, 2, 1 mm
    • Absorbance Range: 0.008 - 1.5
    • Detection Limit: 0.4 ng/µl (dsDNA)
    • Maximum Concentration: 750 ng/µl (dsDNA)
    • Measurement Time: < 3 seconds
    • Cuvette Dimensions: 12.5 mm x 12.5 mm, up to 48 mm H
    • Type: Masked cuvette
    • UL/CSA and CE: All units are approved to these standards
    Learn More
    Thermo-Forma-Nanodrop-2000-Spectrophotometer-UV-Vis-Reader-17429
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Scientific Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Thermo Scientific Nanodrop 2000 Spectrophotometer UV/Vis Reader

    Cambridge ID #: 18171

    Features:

    Enhance the limit of detection for DNA, RNA and protein with the Thermo Scientific NanoDrop 2000c UV-Vis spectrophotometer featuring both microvolume pedestal and cuvette measurement options. The cuvette station is ideal for measuring dilute nucleic acid and protein assays, includes heating and microstirring capabilities, and allows users to perform kinetics and cell culture readings (600nm).

    • Wide spectral range (190-840nm) for measuring a variety of samples types:
      • Peptides (205nm)
      • DNA and RNA (260nm)
      • Purified protein (280nm)
      • Toxicology assays and industrial dyes (490nm)
      • Gold nanoparticles (520nm)
      • Colorimetric protein assays (BCA 562nm, Bradford 595nm, Modified Lowry 650nm, Pierce 660 660nm)
      • Optical Density measurements (600nm)
    • Combining the patented sample retention system with cuvette capability accommodates low and high concentrations
      (0.4 to 15,000 ng/µL dsDNA and 0.01 – 400 mg/mL BSA)
    • Pedestal measurements that require only 0.5 – 2 µL of your sample and do not require sample dilution, even for highly concentrated samples
    • Calculates sample purity ratios (260/280 nm and 260/230 nm)
    • Pre-configured methods for DNA, Protein A280, Microarray, Protein and Labels, Pierce 660, Bradford, BCA, and Lowry
    • Fast measurement time of less than 5 seconds, 10 -15 seconds from sample pipette to wipe
    • User-friendly software that includes custom methods and data export capabilities

    Nanodrop 2000C Specifications:

    • Instrument Type: Spectrophotometer  
    • Minimum Sample Volume: 0.5 µl
    • Recommended Sample Volume, Nucleic acid: 1 µl
    • Recommended Sample Volume, Proteins: 2 µl
    • Sample Number: 1
    • Path Length: 1 mm (auto-ranging to 0.05 mm)
    • Light Source(s): Xenon flash lamp
    • Detector Type: 2048 - element linear silicon CCD array
    • Wavelength Range: 190 - 840 nm
    • Wavelength Accuracy: 1 nm
    • Spectral Resolution: ≤ 1.8 nm (FWHM at Hg 253.7 nm)
    • Absorbance Precision: 0.002 (1 mm path)
    • Absorbance Accuracy: 3% (at 0.74 at 350 nm)
    • Absorbance Range: 0.04 - 300 (10 mm equivalent)
    • Detection Limit: 2 ng/µl (dsDNA)
    • Maximum Concentration: 15,000 ng/µl (dsDNA)
    • Measurement Time: 5s (typical)
    • Footprint: 14 x 20 cm
    • Weight: 2.1 kg
    • Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
    • Operating Voltage: 12 vdc
    • Operating Power Consumption: 12 - 18 W (max 30 W)
    • Standby Power Consumption: 5 W
    • Software Compatibility: Operating software for the NanoDrop 2000 and NanoDrop 2000c. Compatible with Professional versions of Windows 8.1 (64 bit), and Windows 7 (32 and 64 bit).    

    Cuvette Specifications:   

    • Z-Height: 8.5 mm
    • Heating: 37 ± 0.5 °C
    • Stirrer: 150-850 rpm
    • Path Length: 10, 5, 2, 1 mm
    • Absorbance Range: 0.008 - 1.5
    • Detection Limit: 0.4 ng/µl (dsDNA)
    • Maximum Concentration: 750 ng/µl (dsDNA)
    • Measurement Time: < 3 seconds
    • Cuvette Dimensions: 12.5 mm x 12.5 mm, up to 48 mm H
    • Type: Masked cuvette
    • UL/CSA and CE: All units are approved to these standards
    Learn More
    Thermo-Scientific-Nanodrop-2000-Spectrophotometer-UV-Vis-Reader-18171
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping