We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Uplc Sample Manager: 1-1 of 1

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Waters Acquity Sample manager UPLC Sample Manager

Waters Acquity Sample manager UPLC Sample Manager

Cambridge Scientific ID #'s: 15340, 15769

Specifications:

  • Number of sample plates: Total of two plates, expandable to up to 22 plates with optional Sample Organizer (see below):
    • 96 and 384 microtiter plates
    • 48 position 2.00-mL vial plates
    • 48 position 0.65-mL micro-centrifuge tube plates
    • 24 position 1.50-mL micro-centrifuge tube plates
  • Maximum sample capacity: 768 in two 384-well plates; expandable to up to 8,448 samples with optional Sample Organizer
  • Number of sample injections: 1 to 99 injections per sample
  • Injection volume range: 0.1 to 50.0 iJL, in 0.1 iJL increments, partial or full loop mode; 10ul loop is standard; 1, 2, 5, 20, and 50-uL loops also available
  • Sample delivery precision(full loop injection mode): < 0.3% RSO, full loop, standard lO-iJL loop (default wash/purge conditions), per Waters AQT/SystemsQT protocol
  • Sample delivery precision(PLNO injection mode): < 1% RSO within 20% to 75% of loop volume for 1, 2, 5, 10, 20, and 50-iJL loops, UV detection
  • Injector linearity: > 0.999 coefficient of deviation (from 20% to 75%, partial loop overfill mode (PLNO injection mode), per Waters' AQT/SystemsQT protocol
  • Sample temperature control:0 to 40.0 ·C, settable in 0.1 ·C increments (assumes an ambient temperature of 25.0 ·C). At an ambient temperature of 21.0 ·C or lower the sample manager will maintain the temperature of the sample compartment down to 4.0 ·C with a tolerance of -2.0/+6.0 ·C, when configured with the maximum number of vials and/or plates
  • Injection cycle time:
    • < 15 sec between multipe injections with "load ahead" enabled
    • 30 sec with single weak wash, lO-iJL loop, pressure assist mode
  • Sample probe: XYZZ based needle-in-needle design
  • Minimum sample required: 5 uL residual, using maximum recovery 2-mL vials (zero offset)
  • Wash solvents: Two degassed: strong solvent and weak wash solvent, programmable to suit application
  • Sample carryover: < 0.005% or < 2.000 nL, whichever is greater
  • Advanced operations: Loop off-line mode, load ahead
  • Unattended operation: Leak sensors, full diagnostic data control captured through console software
  • Primary wetted material: Titanium alloy, 316 stainless steel, fluoropolymer, fluoroelastomer, PPS alloy, PEEK alloy, PPS, PEEK, OLC coating, gold