Agilent 1260 Series – G7112B HPLC Binary Pump

Cambridge Scientific ID: 28724 Category: Tag: Brands:

Description

Product Description G7112B

The Agilent 1260 Infinity II Binary Pump is suited for LC applications using conventional or superficially porous particle columns, as well as STM column  technology. Gradient formation is based on a high-pressure mixing principle. Standard or low delay volumes can be easily configured by the user. The Agilent 1260 Infinity II Binary Pump offers reproducible gradients and high-performance, providing high-throughput and fast separations. The pump is suitable for routine applications, with UV or MS detection, where high speed and resolution with uncompromised data quality are required. 

Specifications:

Physical Specifications;

  • Weight: 17.6 kg (38.8 lbs)
  • Dimensions (height × width × depth): 180 x 396 x 436 mm (7.1 x 15.6 x 17.2 inches)
  • Line voltage:  100 – 240 V~, ± 10 %
  • Line frequency: 50 or 60 Hz, ± 5 %
  • Power consumption: 90 VA, 74 W
  • Ambient operating temperature: 4–55 °C (39–131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95 % r.h. at 40 °C (104 °F)
  • Operating altitude:  Up to 3000 m (9842 ft)
  • Non-operating altitude: Up to 4600 m  (15091 ft)

Performance Specifications;

  • Hydraulic system: Two dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons
  • Flow range:  settable: 0.001 – 5 mL/min, recommended: 0.05 – 5.0 mL/min
  • Flow precision: ≤0.07 % RSD or < 0.02 min SD, whichever is greater
  • Flow accuracy:  ± 1 % or 10 µL/min, whichever is greater 
  • Pressure operating range: Up to 60 MPa (600 bar, 8702 psi) up to 5 mL/min
  • Pressure pulsation: 
      • < 2 % amplitude (typically < 1.3 %), or
      • < 0.3 MPa (3 bar, 44 psi), whichever is greater
      • Low delay volume configuration: < 5 % amplitude (typically < 2 %)
  • Compressibility compensation: Pre-defined, based on mobile phase compressibility
  • Recommended pH range: 1.0 – 12.5
  • Gradient formation: High-pressure binary mixing
  • Delay volume:
      • Standard delay volume
      • Configuration: :600 – 900 µL, (includes 400 µL mixer)
      • Low delay volume configuration:120 µL
  • Composition range: Settable: 0 – 100 %, Recommended: 1 – 99 % or 5 µL/min per channel, whichever is greater
  • Composition precision: < 0.15 % RSD or < 0.04 min SD, whichever is greater
  • Composition accuracy: ± 0.35% absolute
  • Integrated degassing unit: 
      • Number of channels: 2
      • Internal volume per channel: 0.45 mL
  • Communication: 
    • Controller Area Network (CAN)
    • Local Area Network (LAN)
    • Extended Remote Interface (ERI)
    • Universal Serial Bus (USB)

Contact Us