Agilent 1290 Series – G7117B HPLC Diode Array Detector

Cambridge Scientific ID: 28556 Category: Tag:

Description

The Agilent 1290 Infinity II Diode Array Detector (DAD) is based on the Agilent Max-Light cartridge cell with optofluidic waveguides that improve light transmission to near 100% efficiency sacrificing resolution caused by cell dispersion effects.  With typical detector noise levels of < ±0.6 µAU/cm the 60 mm flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells. 

Any compromising refractive index and thermal effects are almost completely eliminated, resulting in significantly less baseline drift for more reliable and precise peak integration. For fast separations, this detector has multiple wavelength and full spectral detection at sampling rates up to 240 Hz.

Specifications: 

Physical Specifications:

  • Weight: 11.5 kg (25.4 lbs)
  • Dimensions (height × width × depth): 140 x 396 x 436 mm (5.5 x 15.6 x 17.2 inches)
  • Line voltage:  100 – 240 V~, ± 10 %
  • Line frequency: 50 or 60 Hz, ± 5 %
  • Power consumption: 110 VA, 100 W
  • Ambient operating temperature: 4 – 55 °C (39 – 131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity:  < 95 % r.h. at 40 °C (104 °F)
  • Operating altitude: Up to 3000 m (9842 ft)

Performance Specifications:

  • Detection Type: 1024-element photodiode array
  • Light source: Deuterium lamp
  • Number of signals: 8
  • Maximum data rate: 240 Hz (both spectra and signals)
  • Short term signal noise (ASTM): 
  • With 10 mm Max-Light cartridge cell: <±3·10-6 AU/cm at 230 nm, slit width 4 nm, TC 2 s
  • With 60 mm Max-Light cartridge cell: <±0.6·10-6 AU/cm at 230 nm, slit width 4 nm, TC 2 s
  • Drift: <0.5·10-3 AU/h at 230 nm
  • Linear absorbance range: >2 AU (5 %) at 265 nm, typically 2.5 AU (5 %)
  • Wavelength range: 190 – 640 nm
  • Wavelength accuracy: ±1 nm, self-calibration with deuterium lines
  • Wavelength precision: <±0.1 nm
  • Wavelength bunching:  2 – 400 nm, programmable in 1 nm steps
  • Slit width: 1, 2, 4 , 8 nm
  • Diode width: ~0.5 nm
  • Nominal spectral resolution: < 1 nm
  • Time programmable: Wavelength, polarity, peak width, lamp bandwidth, auto balance, wavelength range, threshold, spectra storage mode
  • Flow cells:
      • User-exchangeable, self-aligning cartridge cells with RFID tags.
  • Max-Light Cartridge Cell (Standard): 10 mm, V = 1.0 µL
  • Max-Light Cartridge Cell (High Sensitivity): 60 mm, V = 4 µL
  • Max-Light Cartridge Ultra Low Dispersion (ULD) Cell: 10 mm, V = 0.6 µL
  • Max-Light Cartridge High Dynamic Range (HDR) Cell: 3.7 mm, V = 0.9 µL
  • Max-Light Cartridge Cell LSS: 10 mm, V = 1.0 µL
  • Maximum Operating Pressure (MOP)1: 70 bar
  • Maximum Incidental Pressure (MIP)2: 150 bar
  • Spectral tools: Data analysis software for spectra evaluation, including spectral libraries and peak purity functions
  • Analog output:  Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
  • Instrument control:
      • Lab Advisor B.02.06 or above
      • LC and CE Drivers A.02.11 or above
      • For details about supported software versions refer to the compatibility
      • Matrix of your version of the LC and CE Drivers.
  • Local control: Agilent Instant Pilot (G4208A) B.02.19 or above
  • Communicaiton: 
      • LAN, Controller Area Network (CAN), USB
      • ERI: ready, start, stop and shut-down signals

GLP:  RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, usage). Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with deuterium lines.