Description
Multi-purpose systems providing fast, efficient cell fusion in hybridoma production, hybrid cell formation and nuclear transfer applications, as well as square wave electroporation for transfecting genes and other molecules into mammalian cell lines. Meet your exact needs with preconfigured systems and a choice of basic or advanced systems.
Specifications:
Firmware Specifications;
- Electrofusion Quick Start Menu: Up to 3 protocol steps, ordered AC-DC-AC
- Electrofusion User Defined Protocols: Up to 19 AC protocol steps and up to 1 DC step, organized in any order
- Electrofusion Preset Protocols: Over 20 Preset Protocols for electrofusion applications
- Electroporation Quick State Menu: Yes
- Electroporation User Defined Protocols: Yes
Square Wave Pulse, DC;
- Voltage Range:
-
-
- LV Mode: 5 to 500 V in 1 V steps
- HV Mode: 505 to 3000 V in 1 V steps
-
- Voltage Accuracy:
-
-
- LV Mode: 5%
- HV Mode: 5%
-
- Pulse Length Range:
-
-
- LV Mode: 10 to 999 µs in 1 µ steps
- LV Mode: 1 to 999 ms in 1 ms steps
- HV Mode: 10 to 600 µs in 1 µs steps
-
- Multiple Pulsing
-
-
- LV Mode: 0 to 100 pulses per sample
- HV Mode: 0 to 100 pulses per sample
-
- Pulse Interval: 0.1 s to 10 s
Alignment (Pre-Pulse), AC;
- Frequency: 0.2 to 2 MHz in 0.1 MHz steps
- Voltage: 5 to 75 V in 5 V steps
- Duration: 0 to 99 s in 1 s steps
- Wave Shape: Sine wave
Post-Fusion,AC;
- Frequency: 0.2 to 2 MHz in 0.1 MHz steps
- Voltage: 5 to 75 V in 5 V steps
- Duration: 5 to 75 V in 5 V steps
- Wave Shape: Sine wave
Other Specifications;
- Charging Time: LV = 7 s, HV = 7 s
- DC Monitoring:
-
-
- Protocol Name, Steps Executed,
- Time/Date, Error Conditions, Pulse
- Voltage, Pulse Current,
- Pulse Width, Pulse #, Droop %,
- Sample Voltage, Sample Current and
- Sample Resistance
-
- Display: 7-inch full color display
- Controls: Touch Screen
- Programmability: Stores over 1000 protocols
- DC Arc Control: Yes
- Pre-Pulse Sample Load Check: Ves (20 VDC)
- Computer (Optional): PC running Microsoft Windows XP, 7, 8.1 or 10
- Communications: USB
- Data File Format: Comma Separated Values (CSV)
- Remote Operation: Yes, using Foot Pedal control
- Accessory Connector Type: Coaxial
- Power Ratings: 70 W idle and 900 W pulsing
- Input Voltage Ratings: 100 to 240 VAC, 50/60 Hz
- Dimensions (H x W x D): 13 x 12 x 13 in
- Weight: 22 lb
- Atmospheric Specifications
-
-
- Operating Temperature: 4°C to 40°C (40°F to 104°F)
- Storage Temperature: -10°C to 70°C (14°F to 158°F)
- Operating Humidity: 20% to 80% RH, non-condensing
- Storage Humidity: 20% to 80% RH, non-condensing
-
- Mode of Operation: Continuous
- Classification: Class I
- Pollution: IP2X
- Installation: Category II