Description
Single-use fully integrated benchtop TFF system for use in lab scale process development ranging from 2mL – 15L. Compatible with hollow fiber or flat sheet filters, this system offers many user-defined set-point controls so you can run complex applications in fully-automated modes.
KrosFlo KR2i TFF systems achieve an unparalleled combination of configurability and user-simplicity through modular, plug-and-play hardware. All components, either directly or indirectly, connect to the main pump, which then communicates with the KF Comm 2 software for control and monitoring. The Fully integrated KrosFlo KR2i TFF System features a digital peristaltic pump, graphical LCD display, digital pressure monitor, KR2i Pump head, automatic back pressure valve, filter module stand, and KF Comm real-time data collection software.
Specifications;
KrosFlo TFF System:
- Filter Mode: Hollow Fiber Flat Sheet Cassettes
- Recommended Process Volume: 2 mL- 10 L 12 mL – 15 L
- Filter Surface Area: 13 cm²-3700 cm² 100 cm² – 5000 cm²
- Main Drive / Feed Pump and Stand:
-
-
- Easy-Load Pump Head-ip to 2.3 LPM (600 RPM)
- Use with tubing sizes #13, #14, #16, #17, #18 and #25.
- Integrated stand for hollow fibers
-
-
- Automatic Backpressure Control Valve (ABV): Controls user-set process TMP or permeate pressure
- Tablet as HMI: Microsoft Surface Pro with Krosflo RPM control and data acquisition software
- Auxiliary Pump: KorsFlo Junior, flowrates up to 0.3 LPM
- System Scales:
-
-
- Maximum Weight: 20,000 g
- Readability: 0.1 g
- Platform Dimensions: 7.7” x 7.7” (17.8 cm x 17.8 cm)
-
-
- Enclosures: IP33 rated plastic enclosure. Wipe down cleanable.
- Environmental Requirements:
-
-
- Operating Temperature: 0°C – 40°C
- Relative Humidity: 10% – 90%
-
-
CTech FlowVPX System:
- Linear Range-Finger Technology: Automatically identifies linear region of absorbance data to verify compliance with Beer-Lambert Law
- Flow Cell Volume:
-
-
- 3 mm Flow Cell: 0.9 mL
- 10 mm Flow Cell: 9.0 mL
-
-
- Spectroscopic Engine: Agilent Cary 60
- Qualification Slope Range: 0.10 Au/mm to 46 Au/mm using NIST-traceable slope standards
- Qualification Slope Range: ±2%
- Maximum Pathlength:
-
-
- 3 mm Flow Cell: 3.000 mm
- 10 mm Flow Cell: 5.000 mm
- Minimum Pathlength Step: 0.001 mm
- Delivery Fiber Length: 3 m
-
-
KONDUiT Add-On Monitor
- Inputs: 2 Conductivity Inputs, 2 Temperature Inputs
- Sensor Size: ¼” HB and ½” HB
- Conductivity Range: 0.1 to 100 mS/cm
- Conductivity Accuracy:
-
-
- 0.1 mS/cm–2 mS/cm: ±0.1 mS/cm
- 2 mS/cm–50 mS/cm: ±5%
- 50 mS/cm–100 mS/cm: ±5% (Typical)
- Temperature Range: 0°C–70°C
- Temperature Accuracy: ±0.2°C or better
-
-
Auxiliary Components:
- Pressure transducer:
-
-
- Up to 3 single-use sensors
- Pressure Range: -7 to 75 psi (-0.48 to 5.2 bar)
- Polysulfone, luer-style ports
-
- Tubing: PharmaPure, TPE, size #14 and #16
- Stand: Integrated stand with hollow fiber holder
- Auxiliary Component Octopus cable: Allows for connectivity of scales, auxiliary pumps, and KONDUiT System
- Reservoirs (Optional): 15 mL, 50 mL, 250 mL, 500 mL polypropylene conical containers, caps with ported inlets, conical holders
- High-Performance pump head(Optional):
-
- High-performance pump head, up to 2.9 LPM
- For use with tubing sizes #15, #24, #35, and #36
- Note: Pump will accept up to two (2) pump heads
Power Requirements:
- KR2i System:
-
-
- Supply voltage: 90–260 Vrms @ 50/60 Hz (universal input)
- Max current: 2.2 A @ 115 Vrms or 1.1 A @ 230 Vrms
-
-
- Cary 60: 90 VAC–265 VAC, frequency 47 Hz–63 Hz
- VPX power input: 24 VDC, 0.6 A max current draw
- KONDUiT:
-
-
- Input power supply range: 100 VAC–240 VAC
- Input Frequency: 47 Hz–63 Hz
- KONDUiT Power input: 24 VDC, 0.625 A max current draw
-
-
- FlowVPX:
-
-
- Power supply input: 100 VAC–230 VACFrequency: 50 Hz–60 Hz
-
-
General:
- Dimensions:
-
-
- KR2i Main pump: 267 × 203 × 203 mm (10.5” × 8” × 8”)
- Auxiliary Pumps (2): 140 x 178 x 160 mm (5.5” x 7” x 6.3”)
- KONDUiT: 197 x 120 x 114 mm (7.75” x 4.75” x 4.5”)
- Scales (2): 330 x 203 x 97 mm (13” x 8” x 3.8”)
- FlowVPX: 120 x 100 x 230 mm (4.72” x 3.94” x 9.06”)
- Cary 60: 483 x 559 x 203 mm (22” x 8” x 19”)
-
-
- Weights:
-
-
- KR2i Main pump: 5.9 kg (13 lb)
- Auxiliary Pumps (ea): 2.2 kg (4.8 lb)
- Konduit: 1.6 kg (3.53 lb)
- Scales (ea): 2.7 kg (6 lb)
- Cary 60: 18.1 kg (40lb)
- FlowVPX (3 mm flow cell): 4.31 kg (9.5 lb)
-
-