Thermo Fisher Scientific NanoDrop OneC Spectrophotometer UV/Vis Reader

Description

NanoDrop One/One Microvolume UV-Vis Spectrophotometer

Ensure downstream application success with a microvolume spectrophotometer that accurately measures concentration and purity from just 1-2 µL of nucleic acid or protein samples. 

Specifications: 

  • Certifications/Compliance: All NanoDrop instruments are approved to CE and UL/CSA.
  • Compatibility: DYMO LabelWriter 450 printer, Bluetooth keyboard, mouse and barcode reader
  • Concentration: dsDNA: Pedestal: 27,500 ng/μL BSA (IgG): Pedestal: 820 (400) mg/mL
  • Connections: Three USB-A ports, Ethernet, Bluetooth™ and Wi-Fi (Only available on instruments with Wi-Fi/Bluetooth support)
  • Description: NanoDrop One Microvolume UV-Vis Spectrophotometer with Wi-Fi
  • Detection Range: 
      • dsDNA: Pedestal: 2.0 ng/µL
      • Cuvette: 0.2 ng/µL
      • BSA (IgG): Pedestal: 0.06 (0.03)
      • mg/mL, Cuvette: 0.006 (0.003) mg/mL
  • Detector Type: 2048-element CMOS Linear Image Sensor
  • Display: 7 in. High Definition Color Display, 1280 x 800 pixels
  • Dimensions (L x W x H): 20 x 25.4 x 32.3 cm (8 x 10 x 12.7 in.)
  • Languages: English, French, German, Spanish, Polish, Chinese, Japanese, Korean
  • Light Source: Xenon Flash
  • Spectral Bandwidth: ≤1.8 nm (FWHM at Hg 254 nm)
  • Voltage: 12 VDC
  • Wavelength Range: 190 to 850 nm
  • For Use With (Application): Nucleic Acid A260, A260/A280, A260/A230 and Labeled Nucleic Acids;, Protein A280 and A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, Kinetics, UV-Vis, and Custom Methods
  • Keypad: Built-in touchscreen, multipoint capacitive touch
  • Measurement Time: 8 seconds
  • Pathlength: 0.030 to 1.0 mm (auto-ranging)
  • Photometric Accuracy: 3% at 0.97 A, 302 nm, (Absorbance expressed at Abs/mm at 25°C)
  • Photometric Range: 10 mm equivalent: Pedestal: 0–550 A; Cuvette: 0–1.5 A
  • Power Consumption: Operating: 12 to 18 W; Standby: 5 W
  • Processor: Android 
  • Repeatability: Typical: 0.002 A (1.0 mm path) or 1%CV, whichever is greater (SD of 10 individual measurements at 0.97 A)
  • Sample Temperature: Temperature Control (cuvette only) 37 °C
  • Sample Volume (Metric): Minimum 1μL
  • System Requirements: Windows 8.1 and 10, 64 bit
  • Wavelength Accuracy: ±1 nm
  • Weight (English): 7.9 lb.z
  • Weight (Metric): 3.6 kg

Contact Us