Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Agilent: 1-15 of 71

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Cambridge ID #: 18290

Features:

  • Mass accuracy within 2 ppm gives you complete confidence in your analysis.
  • Powerful Agilent Jet Stream source enables you to uncover low level components.
  • Wide in-spectrum dynamic range facilitates simultaneous measurement of minor components in the presence of intense background interferences.
  • The latest developments in Agilent Infinity II UHPLC, 2D-LC, SFC, and even GC-APCI chromatographic interfaces give you blazing fast acquisition speed.
  • Powerful MassHunter software provides the latest software capabilities for profiling, characterizing, identifying, and quantifying compounds in complex mixtures via high-definition MS and MS/MS.
  • Check out the latest developments in untargeted screening and quantitation using Agilent’s All Ions MS/MS technique.

Specifications:

  • Sensitivity, MS mode, electrospray on-column, 400 µL/min flow rate: 200:1 RMS; Option 200: 60:1 RMS
  • Sensitivity, MS/MS mode, electrospray on-column, 400 µL/min flow rate: 500:1 RMS; Option 200: 180:1 RMS
  • Mass resolving power: Greater than 10,000 at 118 m/z; Greater than 20,000 FWHM at 1,522 m/z
  • Mass accuracy, MS mode, electrospray on-column, 400 µL/min: Better than 2 ppm RMS as measured from 10 repeat injections
  • Mass accuracy, MS/MS mode, electrospray on-column, 400 µL/min: Better than 3 ppm RMS on m/z 397 as measured from 10 repeat injections
  • Mass accuracy temperature stability, MS mode: Maintain 1 ppm mass accuracy (variations < 3 °C from calibration temperature)
  • Dynamic range: Up to 5 decades
  • Mass range: m/z 100 – 20,000 extended mass range m/z 50 – 1,700 or 50 – 3,200 for both high resolution and extended dynamic range modes Quadrupole up to 4,000 m/z
  • Spectral acquisition rate, MS mode: 50 spectra/second
  • Spectral acquisition rate, MS/MS mode mode: 50 MS/MS spectra/second
  • Positive to negative switching:5 seconds

Includes:

  • G5611A 1260 Quat Pump
  • G5667A 1260 HiP BioALS
  • G1316A 1260 TCC
  • G4212B 1260 DAD
  • G5664A 1260 BioFC-AS
  • Computer loaded with MassHunter BioConfirm (G829AA), Agilent SpectrumMill Proteomics (G2721AA), Mass Profiler Professional (G3835AA) and Personal METLIN metabolite database (G6825AA) software.
Learn More
Agilent-6530-QTOF-with-1260-Infinity-Bioinert-HPLC-LC-MS-System-18290
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17966, 16346, 17971, 13182, 16326

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17966
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1260 Series - G1310B HPLC Isocratic Pump

Agilent 1260 Series - G1310B HPLC Isocratic Pump

Cambridge ID #: 17964

The Agilent Technologies 1200 Series (G1310B) 1260 Infinity Isocratic Pump is a HPLC workhorse for demanding QA/QC and routine applications, designed to provide virtually pulse-free and stable solvent flow. This delivery principle allows variable stroke volume optimized to selected flow rate. The broadened pressure range with maximum pressure of 600 bar allows the use of small particle size columns, longer columns, or alternative solvents of higher viscosity. Additionally, the G1310B is the ideal pump for GPC/SEC applications where run-to-run and day-to-day precision of retention times are important.

 

Specifications:

  • Settable flow range: set points 0.001 - 5 mL/min, in 0.001 mL/min increments
  • Flow range: 0.2 to 10.0 mL/min
  • Flow precision: ≤ 0.07 % RSD or ≤ 0.02 min SD
  • Flow accuracy: ± 1 % or 10 μL/min whatever is greater, pumping degassed H2O at 10 MPa (100 bar)
  • Pressure operating range:
    • Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 mL/min
    • Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 mL/min
Learn More
Agilent-1260-Series---G1310B-HPLC-Isocratic-Pump-17964
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6420A Triple Quad LC/MS System

Agilent 6420A Triple Quad LC/MS System

Cambridge ID #: 17976

The Agilent 6420A Triple Quadrupole LC/MS System is equipped with performance specifications in Signal-to-Noise ratio and Instrument Detection Limit for routine analysis.

Specifications:

  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI positive: S/N > 6,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 2,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 60 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 60 fg
  • Mass range: m/z 5 – 2,250
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:1 Da from 5 – 1,000 m/z; 0.01% from 1,000 – 2,000 m/z; 0.02% from 2,000 – 2,250 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment, > 40,000 ion transitions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms

Features:

  • 1260 Infinity Binary Pump Clinical
  • 1260 Infinity high perfomance degasser clinical edition
  • 1260 Infinity high perfomrance autosampler clinical edition
  • PEAK Nitrogen generator system
Learn More
Agilent-6420A-Triple-Quad-LC-MS-System-17976
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1312A HPLC Binary Pump

Agilent 1200 Series - G1312A HPLC Binary Pump

Cambridge ID #: 17895

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1312A-HPLC-Binary-Pump-17895
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1315D HPLC Diode Array Detector

Agilent 1200 Series - G1315D HPLC Diode Array Detector

Cambridge ID #: 17896

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1315D-HPLC-Diode-Array-Detector-17896
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Cambridge ID #: 17898

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment---Heater-17898
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1321A HPLC Fluorescence Detector

Agilent 1200 Series - G1321A HPLC Fluorescence Detector

Cambridge ID #: 17897

This user-friendly detector brings high sensitivity fluorescence detection for you needs whether used alone or in an automated Agilent 1200 Series system. One run will provide quantitative data and fluorescence spectra all the while improving sensitivity and selectivity with the simultaneous multi-wavelength detection capabilities.

Specifications:

  • Environment: 0 – 40°C
  • Dimensions: 17 x 13.5 x 5.5 in
  • Weight:5 lbs
  • Flow Cells: 8 uL volume and 20 bar pressure max
  • Scan Speed: 28 ms/data point
  • Step Size: 1 – 20 nm
  • Wavelength Repeatability: +/- 0.2 nm
  • Wavelength Accuracy: +/- 3 nm
  • Single Wavelength Operation: RAMAN (H2O) > 500
  • Ex: 350 nm
  • Em: 397 nm
  • Dark Value: 450 nm
  • Dual Wavelength Operation: RAMAN (H2O) > 300
  • Ex: 350 nm
  • Em: 397 nm
  • Dark Value: 450 nm
  • Pulse Frequency: 296 Hz for single signal mode. 74 Hz for economy mode
  • Maximum Data Rate: 18 Hz
  • Excitation Monochromator Range: 200 – 1200 nm
  • Bandwidth: 20 nm
  • Emission Monochromator Range: 200 – 1200 nm
  • Bandwidth: 20 nm
Learn More
Agilent-1200-Series---G1321A-HPLC-Fluorescence-Detector-17897
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 17899, 16300

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-17899
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1379B HPLC Well Plate Autosampler

Agilent 1200 Series - G1379B HPLC Well Plate Autosampler

Cambridge ID #: 17900

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1379B-HPLC-Well-Plate-Autosampler-17900
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G1316C HPLC Column Compartment / HeaterImage Coming Soon

Agilent 1290 Series - G1316C HPLC Column Compartment / Heater

Cambridge ID #: 17708

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---G1316C-HPLC-Column-Compartment---Heater-17708
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G4220A HPLC Binary PumpImage Coming Soon

Agilent 1290 Series - G4220A HPLC Binary Pump

Cambridge ID #: 17710

Features:

The Binary pump is designed for highest performance, GLP compliance and easy maintenance.

It includes the following features:

• Seal wash for continued high lifetime of pump seals for buffer applications.

• Solvent selection valve for method flexibility.

• Jet Weaver for optimum mixing performance with a minimum of delay volume.

• Automatic purge function for ease of use and unattended preparation of the system.

• Auto tuning of the delivery cycle for compensation of elasticity and solvent volume change effects (compressibility, thermal expansion, mixing contraction).

• Solvent selection for optimum flow and composition accuracy.

• Fast defill function for improved intake and delivery performance.

• Two pistons in series design for increased reliability.

• High resolution piston movement control for smooth and reliable motion.

Specifications:

  • Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
  • Settable flow range:  Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
  • Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
  • Flow accuracy:  ±1 % or 10 µl/min, whatever is greater.
  • Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.
  • Pressure pulsation:  <1% amplitude or < 0.5 MPa (5 bar), whatever is greater.
  • Compressibility compensation: Automatic, pre-defined, based on mobile phase selection.
  • Gradient formation: High pressure binary mixing
  • Delay volume: 
    • Jet Weaver V35: <45 µl
    • Jet Weaver V100: <75 µl
  • Composition range Settable range: 0 - 100 %
  • Composition precision: <0.15 % RSD, or 0.01 min SD, whatever is greater
  • Composition accuracy: ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min)
Learn More
Agilent-1290-Series---G4220A-HPLC-Binary-Pump-17710
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G7167B HPLC MultisamplerImage Coming Soon

Agilent 1290 Series - G7167B HPLC Multisampler

Cambridge ID #: 17709

The Agilent 1290 Infinity Multisampler sets a new benchmark in flexibility. This autosampler can handle both vials and microtiter plates (whether shallow or deep) with ease and efficiency. This compact module has the capacity to house up to 6,144 samples plus the robotics to smoothly inject each into the chromatograph in turn. With Agilent’s unique dual- needle design, cycle time can be as low as just 5 seconds. With the multi- wash capability, you can reduce carryover to less than 10 parts per million. This innovative Multisampler is designed to provide maximum flexibility and scalability.

Specifications:

  • Injection range:1- 20 µL in 0.1 µL increments
  • Precision: Typically (0.15% RSD or SD<10 nL
  • Pressure range: Up to 1200 bar
  • Sample viscosity range:2 – 5 cp
  • Sample capacity:
    • 1H Drawer: Up to 8 drawers and 16 positions Shallow well plates (MTP)
    • 2H Drawer: Up to 4 drawers and 8 positions MTP, deep well plates, vials, Eppendorf
    • 3H Drawer: Up to 2 drawers and 4 positions MTP, deep well plates, vials up to 6 mL, Eppendorf
  • Injection cycle time: <10 s using following standard conditions
    • Default draw speed: 100 µL/min
    • Default eject speed: 400 µL/min
    • Injection Volume: 1 µL
Learn More
Agilent-1290-Series---G7167B-HPLC-Multisampler-17709
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - K1316C HPLC Column Compartment / HeaterImage Coming Soon

Agilent 1290 Series - K1316C HPLC Column Compartment / Heater

Cambridge ID #: 17707

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---K1316C-HPLC-Column-Compartment---Heater-17707
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6460C LC/MS System

Agilent 6460C LC/MS System

Cambridge Scientific ID #'s: 17704, 17703

The Agilent 6460C Triple Quadrupole LC/MS System is equipped with Agilent Jet Stream Technology to enable enhanced sensitivity. The 6460 provides a fast and robust solution to simultaneously quantify, screen, and confirm analytes in the laboratory.

  • Greater signal and reduced noise - Agilent Jet Stream technology uses super-heated nitrogen to improve ion generation and desolvation
  • Efficient analysis – fast MRM speeds allow for analysis of over 100 overlapping compounds in a given retention time window
  • Screen, confirm and quantify – Triggered MRM (tMRM) combines fast and sensitive MRM quantitation with the generation of a product ion spectrum for library searching and compound screening and confirmation
  • Fast polarity switching for analysis of both positive and negative ions

Specifications:

  • MRM sensitivity Signal-to-Noise ratio ESI positive: S/N > 30,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 10,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 12.5 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 12.5 fg
  • Mass range: m/z 5 – 3,000
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:
    • Da from 5 – 1,000 m/z
    • 01% from 1,000 – 2,000 m/z
    • 02% from 2,000 – 3,000 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment > 40,000 ion transactions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms
Learn More
Agilent-6460C-LC-MS-System-17704
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping