Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Gas: 271-285 of 313

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Dionex RI-101 HPLC Refractive Index DetectorImage Coming Soon

Dionex RI-101 HPLC Refractive Index Detector

Cambridge ID #: 17922

Features:

This detector is ideal for analysis of components with limited or no UV absorption such as alcohols, sugars, saccarides, fatty acids, and polymers. It provides high sensitivity, fast baseline stabilization and excellent reproducibility.

Specifications:

  • Measuring Method: Deflection type
  • Refractive Index Range:00–1.75°
  • Range:25 to 512 µRIU
  • Linearity: 600 µRIU
  • Noise Level: Less than 2.5 nRIU, response: 1.5 s
  • Autozero: Optical and electronic autozero
  • Flow Cell: 8 µL; 0.05 MPa (7.5 psi) maximum pressure
  • Dead Volume: Less than 600 µL
  • Flow Rate: 10 mL/min (with water)
  • Temperature Control: 30 to 50°C in 1°C steps
  • Response:1, 0.25, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0 s
  • Automated Startup Functions: Purge cycles, equilibration, autozero, baseline drift and noise verification
  • Validation Functions: Noise, temperature, drift, lamp age, lamp voltage, accuracy (determined filling the detector cell with a defined standard solution)
  • Display: Color liquid crystal display, allows real-time baseline monitoring
  • Analog Outputs: Integrator: 0–1 V; Recorder: 0–10 mV
  • Contact Closure Inputs: Auto zero, marker, polarity, purge on/off
  • Contact Closure Outputs: Ready, solvent leak, error
  • Communication: RS-232
  • Power Consumption: 150 VA Max.
  • Dimensions: 260 x 200 x 400 mm (10.1 x 7.8 x 15.6 inches)
  • Weight: 12 kg (27 lbs)
Learn More
Dionex-RI-101-HPLC-Refractive-Index-Detector-17922
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV12 *NEW* Vacuum Pump

Edwards RV12 *NEW* Vacuum Pump

Cambridge ID #: 17436

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.65 litres
  • Oil max: 1 litres
  • Displacement :
      50Hz: 14.2 m3h-1 / 8.4 ft3min-1
      60Hz: 17 m3h-1 / 10 ft3min-1
  • Speed (Pneurop 6602)
      50Hz: 12 m3h-1 / 7.1 ft3min-1
      60Hz: 14.2 m3h-1 / 8.4 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 32 mbar / 24 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 290 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

 

Learn More
Edwards-RV12-*NEW*-Vacuum-Pump-17436
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 Vacuum Pump

Edwards RV3 Vacuum Pump

Cambridge ID #: 22427

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-Vacuum-Pump-22427
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 *NEW* Vacuum Pump

Edwards RV3 *NEW* Vacuum Pump

Cambridge ID #: 17433

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-*NEW*-Vacuum-Pump-17433
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV5 *NEW* Vacuum Pump

Edwards RV5 *NEW* Vacuum Pump

Cambridge ID #: 17434

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement :
      50Hz: 5.8 m3h-1 / 3.4 ft3min-1
      60Hz: 7.0 m3h-1 / 4.1 ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 5.1 m3h-1 / 3.0 ft3min-1
      60Hz: 6.2 m3h-1 / 3.7 ft3min-1
  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 50 mbar / 38 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV5-*NEW*-Vacuum-Pump-17434
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV8 *NEW* Vacuum Pump

Edwards RV8 *NEW* Vacuum Pump

Cambridge ID #: 17435

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.45 litres
  • Oil capacity max: 0.75 litres
  • Displacement:
      50Hz: 9.7 m3h-1 / 5.7 ft3min-1
      60Hz: 11.7 m3h-1 / 6.9ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 8.5 m3h-1 / 5 ft3min-1
      60Hz: 10 m3h-1 / 5.9 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 38 mbar / 28.5 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV8-*NEW*-Vacuum-Pump-17435
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore SA 67120 Water Purification

Millipore SA 67120 Water Purification

Cambridge ID #: 22267
  • The Millipore Milli-Q Synthesis A-10 water purification system delivers type 1, ultrapure water for your applications thatÂ’s pyrogen and RNase free. Applications such as ELISA tests, electrophoresis gel make-up and serum-based cell and tissue culture media perpetration, affinity chromatography, and protein and nucleic acid isolation. The Synthesis system takes pretreated water (either through EDI, Reverse Osmosis, Distillation or Deionization, and pumps it through the Q-Guard cartridge, then passes the water under UV lights at two wavelengths, 185 and 254nm. Organic compounds are oxidized and bacteria is destroyed. The Quantum cartridge then filters out the trace ions and oxidation by products. Purified water is then sent through an ultrafiltration module, and finally through a filter membrane that removes any particles or bacteria greater than 0.22µm in size.
  • The Millipore Milli-q Synthesis A-10 includes a built in A-10 total organic carbon (TOC) monitor, high-precision resistivity meter, while providing complete monitoring of water quality throughout the process. As the process proceeds, the water quality and operation data is recorded in system memory. This Millipore water filter uses a backlit display to show resistivity and TOC Levels in addition to other system functions, for easy monitoring.
  • The Millipore Milli-q Synthesis A-10 has a flowrate of up to 1 liter per minute.
  • Learn More
    Millipore-SA-67120-Water-Purification-22267
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters Sample Organizer UPLC Autosampler Loader

    Waters Sample Organizer UPLC Autosampler Loader

    Cambridge Scientific ID #'s: 14266, 14268

    The ACQUITY UPLC Sample Organizer increases the level of automation and sample processing throughput of the ACQUITY UPLC System. It extends the capacity of the system by more than tenfold for samples in standard ANSI-compliant 96 or 384 well plates; or more than threefold for samples in conventional 2 mL vials.

     

    Features:

    • Plates are transferred in a programmable order from the Sample Organizer to the ACQUITY UPLC System Sample Manager for processing
    • Plate exchange shuttle replaces a plate in the Sample Manager within 15 seconds to support high sample-throughput processing
    • Shelves accessed through the large swing-open front door and slide in easily
    • Accepts any combination of ANSI-compliant well plates and vial holders
    • Temperature control of 4 to 40 °C in 1 °C increments
    • Small footprint
    • Sample capacities:
      • 22 standard ANSI/SBS-compliant 96 or 384 well plates
      • 12 intermediate well plates
      • 8 x 48 – 2mL vials
      • 8 x 24 – 4mL vials
    Learn More
    Waters-Sample-Organizer-UPLC-Autosampler-Loader-14266
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Perseptive Biosystems Scout Column SelectorImage Coming Soon

    Perseptive Biosystems Scout Column Selector

    Cambridge ID #: 6962

    Description:

    Applied Biosystems’ SCOUT Column Selector is an automated multi-column switching unit for use with the BioCAD family of workstations and the INTEGRAL 100Q System. The SCOUT Column Selector allows flow to be diverted to any one of six attached columns. The SCOUT Column Selector offers increased flexibility for both systematic methods development and routine execution of experiments.

    Specifications:

    • Valve body/fluid paths: PEEK, carbon-filled PEEK, PTFE, or HMW polyketone
    • Maximum pressure: 3,000 psi
    • Back pressure: <100 psi at 60 ml/min for each line
    • Column sizes: Up to 24 mm diameter and up to 30 cm length
    • Plumbing: 1/16-inch Valco fittings
    • Dimensions (W x L x H): 9.5 in. x 12 in. x 8 5/16 in. (24.1 cm x 30.5 cm x 21.1 cm)
    • Weight: 10 lbs. (4.5 Kg)
    • Power requirements: 100 V/120 V/220 V/240 V, 50/60 Hz, 1.2 amps
    • Fuse rating: 2-amp SLO-BLO
    • Operating temperature: 4°C to 40°C
    • Operating humidity: 10 to 90% non-condensing
    Learn More
    Perseptive-Biosystems-Scout-Column-Selector-6962
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Shimadzu SIL-HTC HPLC Autosampler

    Shimadzu SIL-HTC HPLC Autosampler

    Cambridge ID #: 22317

    To be used with a Shimadzu 10 HPLC System

     

    Specifications:

    • Sample injection system: Total sample injection, variable sample injection system (zero sample loss during injection)
    • Settable range of injection volumes: to 100 µL (standard), or 1 to 2000 µL (option) (0.1µL steps from 0.1 to 0.9µL, and 1µL steps from 1 to 2000 µL)
    • Sample processing capability:
      • With 1-mL vials: 350
      • With 1.5-mL vials: 140
      • with 4-mL vials:100
      • With micro plates: 4 (96 wells: 284, 284 wells: 1536)
      • with deep well plates: 4 (96 wells: 284, 284 wells: 1536)
    • Injection volume repeatability: RSD: 0.3% max. (at 10µL injection)
    • Cross contamination: 01% max. (for analysis of naphthalene)
    • Injection  volume accuracy:Less than +/- 1% (50µL)
    • Injection volume accuracy correction: Possible
    • of injections: 1-99 times per sample
    • Setting of analysis time: .01– 9999.9 (0.1 minute increments to 999.99 min., 0.1 minutes increments over 1000 min.)
    • Number of steps for injection conditions: Max 102 steps
    • Sample suction speed: 1-15 µL/sec (0.1µL/s step for 0.1-0.9 µL/sec., 1µL/s step for over1 µL/sec.)
    • Rinsing liquid suction speed: 1-35 µL/sec/ (1µL/s step)
    • Maximum pressure: 20.0 Mpa (standard pippings of sample flowpath is PEEK)

    Sample cooler (SIL-HTc only)

    • Method: Direct cooling method (at a setting of 4 deg. C, room temperature must be less than 30 deg. Cand humidity less than 70%)
    • Temperature setting range: 4 to 40 deg. (cooling down to 4 deg. C for room temperature up to 30 deg. C and humidity to 70%)
    • Operating ambient temperature range:4 to 35 deg. C
    Learn More
    Shimadzu-SIL-HTC-HPLC-Autosampler-22317
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters TCM HPLC Column CompartmentImage Coming Soon

    Waters TCM HPLC Column Compartment

    Cambridge ID #: 7445

    Column Heater for Waters Alliance Series

    Specifications:

    • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
    Learn More
    Waters-TCM-HPLC-Column-Compartment-7445
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters Temperature Control Module II HPLC Column CompartmentImage Coming Soon

    Waters Temperature Control Module II HPLC Column Compartment

    Cambridge ID #: 7396

    Column Heater for Waters Alliance Series

    Specifications:

    • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
    Learn More
    Waters-Temperature-Control-Module-II-HPLC-Column-Compartment-7396
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    MicroCal Thermo Vac2 HPLC DegasserImage Coming Soon

    MicroCal Thermo Vac2 HPLC Degasser

    Cambridge ID #: 13729

    Features:

     

    HPLC Degasser



    Specifications:

     

     

    • Sample Degassing and thermostat system

     

     

    Learn More
    MicroCal-Thermo-Vac2-HPLC-Degasser-13729
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Zymark TurboVap 96 Concentration Evaporator

    Zymark TurboVap 96 Concentration Evaporator

    Cambridge ID #: 14611

    Features:

    • Microprocessor controlled evaporation system for simultaneous, automated concentration of multiple samples with unattended operation, convenience and speed.
    • Can accommodate one or two 96-well microplates aor deepwell plates.

     

    Specifications:

    • Power requirements: 100/120V, 50/60 Hz, 10Amps, 220/240V, 50/60 Hz, 5Amps
    • Dimensions (WxHxD): 24" x 12" x 12"
    • Capacity: 2 standard 96 well microplates or deep-well plates
    • Format: 8 x 12 well microplates and deep-well plates
    • Gas flow: 0-90SCFH
    • Minimum operating pressure: 70 PSI
    • Exhaust: 25 CFM blower
    • Temperature range: Ambient to 80°C
    Learn More
    Zymark-TurboVap-96-Concentration-Evaporator-14611
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Dionex Ultimate 3000 ACC-3000  HPLC Autosampler

    Dionex Ultimate 3000 ACC-3000 HPLC Autosampler

    Cambridge ID #: 20019

    Features:

    Reduce the size and cost of your liquid chromatography (LC) system. The Dionex UltiMate ACC-3000 Autosampler Column Compartments provides a cost-effective solution for conventional LC and UHPLC applications at up to 62MPa (9000 psi) operating pressure. It integrates an autosampler and column compartment (with optional sample thermostatting) in a single module and offers performance and flexibility that exceed most analytical method requirements. The number of wear parts have been minimized for trouble-free operation.

    Specifications:

    • Injection Cycle Time: <45 sec.
    • Injection Volume Precision: <0.25%
    • Injection Volume Range: 1 to 200 µL
    • Injection Type: Pulled Loop
    • Sample Capacity: 3 racks
    • Max. Pressure: 620 bar/9000 psi
    • Biocompatible Version: No
    • Linearity: >0.9995
    • Voltage: 100 to 120 V
    • Weight (Metric): 18 kg
    • Description: ACC-3000 Autosampler Column Compartment
    • Carryover: <0.02%
    Learn More
    Dionex-Ultimate-3000-ACC-3000-HPLC-Autosampler-20019
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping