We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Gas: 46-60 of 305

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Cambridge ID #: 13766

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • – 8 µl in 0.01 µl increments with the small loop capillary
    • – 40 µl in 0.01 µl increments with the extended loop capillary
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 40 µl,
    • Typically < 1 % RSD from 1 – 5 µl
    • Typically < 3 % RSD from 0.2 – 1 µl
  • Sample viscosity range: 2 – 5 cp
  • Sample capacity:
    • 2× well-plates (MTP) + 10 × 2 ml vials
    • 100 x 2 ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically, < 30 s using following standard conditions:
    • Default draw speed: 4 µl/min
    • Default eject speed: 10 µl/min
    • Injection volume: 0.1 µl
  • Carry-over:
    • Typically < 0.05 % using the following conditions:
    • Column: 150 x 0.5 mm Hypersil ODS, 3 µm
    • Mobile phase: Water/Acetonitrile = 85/15
    • Column Flow rate: 13 µl/min
    • Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port
Learn More
Agilent-1100-Series---G1377A-HPLC-Well-Plate-Autosampler-13766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 19163, 15934, 16060, 16141, 23204, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-19163
By clicking below we can further assist you with your inquiry. Inquire 7 In Stock Worldwide Shipping
Agilent 1100 Series - G1389A HPLC Autosampler

Agilent 1100 Series - G1389A HPLC Autosampler

Cambridge Scientific ID #'s: 9301, 16033, 10407

Specifications:

  • Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
  • Settable injection volume
    • to 8 µl with small loop capillary
    • to 40 µl with extended loop capillary
  • Precision
    • Typically < 0.5 % RSD from 5 to 40 µl
    • Typically < 1 % RSD from 1 to 5 µl
    • Typically < 3 % RSD from 0.2 to 1 µl
  • Minimum sample volume: µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
  • Carryover
    • Typically < 0.1 % without automated needle wash
    • Typically < 0.05 % with external needle cleaning and 1 µl injection volume
  • Sample viscosity range: 2 - 5 cp
  • Recommended pH-range: - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
  • Material in contact with solvent: Stainless steel, sapphire, PTFE, PEEK, fused silica
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in aintenance areas, error detection and display
  • Housing: All material recyclable

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1389A-HPLC-Autosampler-9301
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1946D LC/MS System

Agilent 1100 Series - G1946D LC/MS System

Cambridge Scientific ID #'s: 10994, 12804

Includes Installation and One year Service Contract

 

Includes:

  • G1946D LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional Front end HPLC

Specifications

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed:
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1946D-LC-MS-System-10994
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - Solvent Tray HPLC Solvent TrayImage Coming Soon

Agilent 1100 Series - Solvent Tray HPLC Solvent Tray

Cambridge ID #: 7147

Agilent 1100 HPLC Solvent Tray for HPLC Systems used to hold containers and organize solvent lines

Learn More
Agilent-1100-Series---Solvent-Tray-HPLC-Solvent-Tray-7147
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Hewlett Packard 1100 Series G1316A HPLC Column Compartment

Hewlett Packard 1100 Series G1316A HPLC Column Compartment

Cambridge ID #: 23892

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Hewlett-Packard-1100-Series-G1316A-HPLC-Column-Compartment-23892
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series HPLC System

Agilent 1200 Series HPLC System

Cambridge ID #: 9593

Includes:

  • Agilent G1322A Degasser
  • Agilent G1311A Quat Pump
  • Agilent G1329A Autosampler
  • Agilent G1330A Autosampler Chiller
  • Agilent G1365D DAD (Diode Array Detector)
  • Agilent G1316A Column Compartment
  • Solvent Tray
  • Computer Loaded with ChemStation
  • Cables and Manuals
Learn More
Agilent-1200-Series-HPLC-System-9593
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1311A HPLC Quaternary Pump

Agilent 1200 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 23953, 22623, 23893

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-23953
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G1312A HPLC Binary Pump

Agilent 1200 Series - G1312A HPLC Binary Pump

Cambridge ID #: 23959

Features:

The Agilent 1200 Series G1312A Binary Pump is designed for top performance high-pressure mixing. This unit's reliable design keeps maintenance to a minimum by using electronically-controlled active inlet-valves for flow rates up to 5.0 mL/min. Floating pistons ensure the highest seal, low internal and external volumes of capillary connections, minimum bench space needed due to two dual-piston, in-series pumps in one housing.

Specifications:

  • Weight: 15.5 kg (34 lbs)
  • Dimensions: 7 x 13.5 x 17 in. (18 x 34.5 x 43.5 cm)
  • Line voltage: 100 – 240 VAC, ± 10%, Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ± 5%
  • Power consumption: 220 VA, 74 W / 253 BTU Maximum
  • Ambient operating temperature: 4–55 °C (41–131 °F)
  • Ambient non-operating temperature: -40–70 °C (-4–158 °F)
  • Humidity: < 95%, at 25–40 °C (77–104 °F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the module
  • Safety standards: IEC, CSA, UL, Installation Category II, Pollution Degree 2

Learn More
Agilent-1200-Series---G1312A-HPLC-Binary-Pump-23959
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1312B HPLC Binary Pump

Agilent 1200 Series - G1312B HPLC Binary Pump

Cambridge Scientific ID #'s: 23496, 23952

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1312B-HPLC-Binary-Pump-23496
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

Cambridge ID #: 22633

Specifications: 

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Noise: ± 0.75 x 10 -5 AU, at 254 nm
  • Drift: 3 x 10-4AU/hr, at 254 nm
  • Linearity: >2 AU upper limit
  • Wavelength range: 190-600 nm
  • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
  • Maximum data rate: 55 Hz
Learn More
Agilent-1200-Series---G1314B-HPLC-Variable-Wavelength-Detector-22633
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Cambridge ID #: 15899

Specifications: 

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Noise: ± 0.75 x 10 -5 AU, at 254 nm
  • Drift: 3 x 10-4AU/hr, at 254 nm
  • Linearity: >2 AU upper limit
  • Wavelength range: 190-600 nm
  • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
  • Maximum data rate: 55 Hz
Learn More
Agilent-1200-Series---G1314C-HPLC-Variable-Wavelength-Detector-15899
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping