Bio-Rad Gene Pulser II Electroporation System

Bio-Rad Gene Pulser II Electroporation System

Cambridge ID #: 6645

Description:

The new Gene Pulser II system is a completely redesigned electroporation system, which offers improved performance, flexibility, sample protection, and safety. The Gene Pulser II system uses the Pulse Trac waveform delivery system to generate the most accurate exponential decay pulses possible for optimal cell transformation within an electroporation cuvette. The Pulse Trac delivery system accurately calculates the time constant of each pulse based on what is actually delivered to the sample.

Specifications:

  • Input voltage: 100/120 V RMS, 50/60 Hz
  • Input current: 15 amp RMS
  • Maximum output voltage and current: 2,500 V at 125 amp peak (normal load); limited to 1,500 A during arc.
  • Output waveform: Pulse Trac exponential decay with RC time constant dependent on sample and capacitor selected
  • Output voltage adjustment: 50–2,500 V range (depending on the capacitor) with 10 V adjustment precision for the high voltage range and 2 V for the low-voltage range (50–500 V).
  • Ambient operating environment: Temperature 0–35°C
  • Humidity: 0–95% without condensation
  • Regulatory: Passes requirements of IEC 1010. In addition, the system passes requirements for FCC, Class A.
  • Dimensions: 34 x 31 x 19 cm
  • Weight: 10.41 kg
Learn More
Bio-Rad-Gene-Pulser-II-Electroporation-System-6645
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Gene Pulser II System Electroporation System

Bio-Rad Gene Pulser II System Electroporation System

Cambridge ID #: 20135

Includes

  • Gene Pulser II
  • Capacitance Extender Plus
  • Pulse Controller Plus
Learn More
Bio-Rad-Gene-Pulser-II-System-Electroporation-System-20135
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Invitrogen Iblot 2 Dry Blot System

Invitrogen Iblot 2 Dry Blot System

Cambridge ID #: 21888

The iBlot 2 Gel Transfer Device is an integral part of the iBlot 2 Dry Blotting System, which consists of the transfer device and consumable transfer stacks that contain the required buffers and transfer membrane (nitrocellulose or PVDF)

  • Complete protein transfer in 7 minutes or less
  • High detection sensitivity and even transfer
  • Increased blotting reliability and reproducibility
  • Flexible gel size formats and membrane types
  • A simple, user-friendly system
  • Options to create new custom programs
  • Built-in tutorial and application notes
  • High-quality transfer stacks that are more compact than before

Rapid, High-quality Protein Transfers

  • For dry electroblotting of proteins from mini-, midi-, and E-PAGE™ gels onto nitrocellulose or PVDF membranes for Western detection
  • Offers high-quality transfer, convenience, and speed, producing crisp, clear bands that remain sharp and straight, with exceptional transfer efficiency
  • Allows users to create custom programs

iBlot 2 Transfers Save Time

  • With the iBlot 2 system, there is no need to prepare buffers, pretreat the gel, or clean up after blotting
  • The total preparation and run time is normally less than 10 minutes per blot for significant time savings compared to conventional Western transfer techniques

How It Works

  • Buffer ion reservoirs are incorporated into the gel matrix (transfer stacks) instead of buffer tanks or soaked papers
  • The high density of ions in the gel matrix enables rapid protein transfer
  • During blotting, the copper anode does not generate oxygen gas as a result of water electrolysis, reducing blot distortion (conventional protein transfer techniques, including wet, semi-wet, and semi-dry, use inert electrodes that generate oxygen)
  • Transfer time is reduced by the shortened distance between electrodes, high field strength, and high current
  • Trapped air bubbles, often created during the manual preparation of the blotting sandwich layers, are easy to avoid due to the de-bubbling design that promotes even and complete transfer

Proteins, Expression, Isolation and Analysis, Western Blotting

Learn More
Invitrogen-Iblot-2-Dry-Blot-System-21888
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Life Technologies iBlot 2 Dry Blot System

Life Technologies iBlot 2 Dry Blot System

Cambridge Scientific ID #'s: 22075, 19805

The revolutionary iBlot Dry Blotting System transfers proteins from polyacrylamide gels to membranes in seven minutes or less. The iBlot® western blotting system offers high transfer quality for downstream immunodetection sensitivities.

  • Fast— protein transfer in 7 minutes or less
  • High quality transfer— efficient transfers without bubbles or distortions
  • Convenient—Self contained unit without the need for additional buffer or external power supply
  • Reproducible—reduces blot preparation and running variability
Learn More
Life-Technologies-iBlot-2-Dry-Blot-System-22075
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Invitrogen Mini Gel Tank Electroporation System

Invitrogen Mini Gel Tank Electroporation System

Cambridge ID #: 16505

The Mini Gel Tank is compatible with a variety of Novex mini gels, NuPAGE mini gels, and Bolt Bis-Tris Plus gels. Each Mini Gel Tank can accommodate up to two gels per run. The unique tank design enables convenient side-by-side gel loading and enhanced viewing during use. Optimized conditions using constant voltage allow for Bolt Bis-Tris Plus gels to be run in approximately 35 minutes. Run times may vary depending on buffer conditions and power supplies being used.

Specifcations:

  • Capacity: Up to 2 gels per run
  • Gel Compatibility: Bolt Bis-Tris Plus Gels, Novex Mini Gels
Learn More
Invitrogen-Mini-Gel-Tank-Electroporation-System-16505
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Benchmark Scientific myGel Mini E1101 *NEW* Electroporation System

Benchmark Scientific myGel Mini E1101 *NEW* Electroporation System

Cambridge ID #: 18281

The Accuris myGel Mini electrophoresis system includes all of the equipment that you need to get up and running - gel tank, power supply and two casting sets. Ideal for personal use, small laboratories or the classroom, this gel box/power supply combination is compact and easy to use. The myGel mini gel box attaches directly to the power supply for a secure connection every time. Selectable parameters include 3 preset voltages - 35V, 50V or 100V - and a 99 minute timer. All are set using the membrane keypad. The safety lid is vented to help dissipate heat generated during electrophoresis, and features a viewing area above the gel. Current will only run through the system when the lid is properly in place on top of the gel box.

 

Specification:

 

  • Output Voltage: 35V, 50V or 100V
  • Timer: 0-99 min. or Cont.
  • Safety: Lid interlock
  • Max. Buffer (ml): 230
  • Gel Capacity: 10.5 x 6cm Two: 5 x 6 cm
  • Weight: 1 lbs / 0.45 kg
  • Dimensions: 7.5 x 5.1 x 2.1 in
  • Electrical: 115V or 230V, 50-60Hz
Learn More
Benchmark-Scientific-myGel-Mini-E1101-*NEW*-Electroporation-System-18281
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Protean i12 IEF Cell

Bio-Rad Protean i12 IEF Cell

Cambridge ID #: 22743

The PROTEAN i12 IEF system is designed for isoelectric focusing (IEF) proteins in immobilized pH gradient (IPG) strips for the first dimension of two-dimensional (2-D) electrophoresis. The PROTEAN i12 IEF cell can run 1–12 IPG strips in 7, 11, 13, 17, 18, or 24 cm focusing trays. Each channel in the isoelectric focusing tray is independently powered, enabling precise control over each IPG strip. This feature makes it possible to run different sample types, different pH gradients, and multiple protocols simultaneously.

 

Specifications:

  • User Interface: Display QVGA resolution (320 x 240) touch screen or mouse control
  • Programmable: Yes
  • Ramping: Step, linear, gradual, and hold voltage ramping for each focusing step. Hold mode as a final step to prevent diffusion when IEF is complete
  • Protocol Capacity: 2 GB
  • Data collection: .dat format
  • Dimensions:3 in x 13.6 in x 15.1 in
  • Weight: 19 lbs
  • Input power: 100–240 VAC, 50/60 Hz
Learn More
Bio-Rad-Protean-i12-IEF-Cell--22743
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Pulsewave 760 Electrophoretic Field Switcher

Bio-Rad Pulsewave 760 Electrophoretic Field Switcher

Cambridge ID #: 18985

Description:

The Pulsewave 760 switcher is a versatile and safe instrument for pulsed field DNA electrophoresis. The unit may be used with Orthogonal Field Alternating Gel Electrophoresis (OFAGE), Clamped Homogeneous Electric Fields, and Field-Inversion Gel Electrophoresis (FIGE). The Pulsewave 760 switcher interfaces with an external power supply and gel box.

Specifications:

  • Switch Intervals: 0.1 to 65,000 sec
  • Forward/Backward Ratio: 0.1 to 99.9:, continuously adjustable, with 0.1 resolution
  • Overload and Short Protection: Fuse and electronic protection circuitry
  • Operating Temperature: 0-35°C
  • Operating Humidity: 0-95%
  • Dimensions (W x L x H): 6.5 x 11.5 x 6.5 in.
  • Footprint: 486 sq. in.
  • Weight: 20 lbs.
Learn More
Bio-Rad-Pulsewave-760-Electrophoretic-Field-Switcher-18985
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore SA 67120 Water Purification

Millipore SA 67120 Water Purification

Cambridge ID #: 22267
  • The Millipore Milli-Q Synthesis A-10 water purification system delivers type 1, ultrapure water for your applications thatÂ’s pyrogen and RNase free. Applications such as ELISA tests, electrophoresis gel make-up and serum-based cell and tissue culture media perpetration, affinity chromatography, and protein and nucleic acid isolation. The Synthesis system takes pretreated water (either through EDI, Reverse Osmosis, Distillation or Deionization, and pumps it through the Q-Guard cartridge, then passes the water under UV lights at two wavelengths, 185 and 254nm. Organic compounds are oxidized and bacteria is destroyed. The Quantum cartridge then filters out the trace ions and oxidation by products. Purified water is then sent through an ultrafiltration module, and finally through a filter membrane that removes any particles or bacteria greater than 0.22µm in size.
  • The Millipore Milli-q Synthesis A-10 includes a built in A-10 total organic carbon (TOC) monitor, high-precision resistivity meter, while providing complete monitoring of water quality throughout the process. As the process proceeds, the water quality and operation data is recorded in system memory. This Millipore water filter uses a backlit display to show resistivity and TOC Levels in addition to other system functions, for easy monitoring.
  • The Millipore Milli-q Synthesis A-10 has a flowrate of up to 1 liter per minute.
  • Learn More
    Millipore-SA-67120-Water-Purification-22267
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Bio-Rad Trans-Blot SD  Semi-Dry Transfer Cell

    Bio-Rad Trans-Blot SD Semi-Dry Transfer Cell

    Cambridge Scientific ID #'s: 16546, 10519

    Features and Benefits

     

    • Transfers take place in as little as 15–60 min
    • Minimal buffer requirements save money
    • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
    • Single-step locking system allows simple, speedy setup
    • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
    • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
    • Safety cover breaks the electrical current when lifted, preventing electrical shock

     

    Applications and Uses

     

    • Western blotting
    • Nucleic acid transfer
    • Northern and Southern blot transfers in 10–35 min
    • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

     

    Features:

     

    • Maximum gel size (W x L), cm: 24 x 16
    • Buffer requirement, ml: 200
    • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
    • Recommended power supply: PowerPac HC (High Current)
    • Dimensions (W x L x H), cm: 37 x 24 x 11
    • Weight, kg/lb: 3.6/7.9
    Learn More
    Bio-Rad-Trans-Blot-SD-Semi-Dry-Transfer-Cell-16546
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

    Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

    Cambridge Scientific ID #'s: 17884, 22074

    Features and Benefits

     

    • Transfers take place in as little as 15–60 min
    • Minimal buffer requirements save money
    • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
    • Single-step locking system allows simple, speedy setup
    • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
    • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
    • Safety cover breaks the electrical current when lifted, preventing electrical shock

     

    Applications and Uses

     

    • Western blotting
    • Nucleic acid transfer
    • Northern and Southern blot transfers in 10–35 min
    • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

     

    Features:

     

    • Maximum gel size (W x L), cm: 24 x 16
    • Buffer requirement, ml: 200
    • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
    • Recommended power supply: PowerPac HC (High Current)
    • Dimensions (W x L x H), cm: 37 x 24 x 11
    • Weight, kg/lb: 3.6/7.9
    Learn More
    Bio-Rad-Trans-Blot-SD-Cell-Semi-Dry-Transfer-Cell-17884
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

    Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

    Cambridge ID #: 23282

    The Trans-Blot Turbo transfer system reduces western blotting setup time to 1 minute and transfer to as little as 3 without sacrificing sensitivity.

    Paired with Trans-Blot Turbo transfer packs or Trans-Blot RTA kits, this system provides a complete solution for fast, high-efficiency transfer of even high molecular weight proteins.
    Used on its own or as part of the V3 Western Workflow, the Trans-Blot Turbo system is the no-compromise solution for high-performance western blotting.

    Features:

    • Fast Transfer Times: Transfer your proteins in as little as 3 minutes.
    • High Throughput: Transfer up to 4 mini or 2 midi gels simultaneously.
    • Flexible Design: Easily customize transfer conditions; compatible with traditional semi-dry consumables.
    • Ease of Use: Reduce set-up time to only 1 minute from opening the gel cassette to starting the transfer.
    • Two Blotting Sandwich Options: Trans-Blot Turbo Transfer Packs or Trans-Blot Ready-to-Assemble Kits
    Learn More
    Bio-Rad-Trans-Blot-Turbo-System-Semi-Dry-Transfer-Cell-23282
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR W-150 Shaker

    VWR W-150 Shaker

    Cambridge ID #: 10528

    Description:

    • True three-dimensional wave action allows precise agitation control
    • Front-mounted controls allow precise adjustments during operation
    • Pitch and speed can be adjusted separately for optimal mixing and washing action
    • Dynamic pitch change mechanism with full range of adjustment (0 to 6°)
    • Timer allows automatic shut-down at the end of set time from 1 to 120 minutes, or switch to continuous cycle for prolonged mixing
    • The waver's variable pitch and speed adjustments are ideal for electrophoresis gel and blot processing Corrosion-resistant construction for long life
    • Chemical-resistant enamel finish. Stable, counter-weighted base for safe operation.
    • Speed: 10 to 150 rpm
    • Pitch Angle: 0 to 6°
    • Maximum Load: 10 kg (22 lbs.)
    Learn More
    VWR-W-150-Shaker-10528
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping