Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Flow Cytometry: 16-30 of 256

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
BD BioScience FACSCanto II 2 Laser Flow Cytometer

BD BioScience FACSCanto II 2 Laser Flow Cytometer

Cambridge ID #: 17183

The BD FACSCanto system breaks new frontiers in flow cytometry by providing an efficient, easy-to-use yet powerful six-color benchtop analyzer. It incorporates many technology advances first developed in the BD LSR II expandable analyzer and the BD FACSAria cell sorter. It supports a broad range of research applications, being particularly suited for rare event analysis with its high speed, great sensitivity, and minimal sample-to-sample carryover.

 

The BD FACSCanto system combines a patented optical design for enhanced signal retention on six fluorescent and two scatter parameters, digital electronics for processing up to 10,000 events per second, and a novel sample injection tube supporting carryover of less than 0.1%. Your total benefit consists of the best fluorescence sensitivity to resolve dim events, cleaner data due to minimal sample contamination, and rapid processing rates, preserving valuable time for science. BD FACSCanto performance overcomes obstacles in rare event analysis and in functional studies for low detection ranges.

 

Includes:

  • Computer w/ FacsDiva Software
  • Fluids Cart
  • 2 laser, Blue(488) and Red (633)
  • 3 PMTs in 4-2 configuration w/ side scatter
  • All Necessary Cables
  • Manuals

 

Optics

Lasers

  • Air-cooled
  • 488-nm solid state, 20-mW laser output
  • 633-nm HeNe, 17-mW laser output
  • Laser Configuration: Spatially separated beams with 9 x 65-μm elliptical spots
  • Optical Alignment Procedure: Fixed, no operator alignment required
  • Flow Cell: 180 x 430-μm rectangular quartz flow cell
  • Collection Optics: Optical-gel coupled 1.2 NA lens
  • FSC Resolution: 1.0 μm
  • SSC Resolution: 0.5 μm
  • Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT
  • FSC Detector: Photodiode with 488/10 BP
  • SSC Detector: PMT with 488/10 BP
  • Fluorescence Detectors: 6 PMTs in 4-2 configuration w/ side scatter
Learn More
BD-BioScience-FACSCanto-II-2-Laser-Flow-Cytometer-17183
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BD BioScience FACSCanto II 3 Laser Flow Cytometer

BD BioScience FACSCanto II 3 Laser Flow Cytometer

Cambridge ID #: 18798

Description:

Built on more than 25 years of BD experience and leadership in flow cytometry and multicolor analysis, the BD FACSCanto™ II system is an easy-to-use benchtop analyzer that delivers proven performance, accuracy, and high-quality results. The BD FACSCanto II can be configured with two or three lasers to detect up to eight colors. It features many innovations, including a true fixed alignment flow cell to minimize startup time and improve reproducibility. The optical system maximizes signal detection and increases sensitivity and resolution for each color in a multicolor assay. These and other capabilities make the BD FACSCanto II ideal for today’s busy clinical lab, providing a high degree of automation and quality control. With optimal reproducibility, the BD FACSCanto II system reduces hands-on technician time and costs associated with repeat testing.

Specifications:

  • Carryover: ≤0.1%
  • Sample Injection: Direct into flow cell
  • Max Particle Size: 50 μm
  • Sample Flow Rate, Min: 10 μL/min
  • Sample Flow Rate, Max: 120 μL/min
  • Sample Acquisition Rate: 10,000 events/second, 6 compensated fluorescence parameters and 2 scatter parameters
  • Sample Dead Volume: 30 μL
  • Sheath Consumption: 1.10 L/h normal operation; <1 mL/h standby
Learn More
BD-BioScience-FACSCanto-II-3-Laser-Flow-Cytometer-18798
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Beckman Coulter FC 500 Flow Cytometer

Beckman Coulter FC 500 Flow Cytometer

Cambridge ID #: 20487

Specifications:

 

 Lasers: 20-mw 488 Argon Ion 

  • Detectors: FS, SS, 5 FL PMT 
  • Flow Cell: 150x450 micron rectangular Channel 
  • Sample Loading: 96-well, 24-well, 40-tube 
  • Signal Processing: 20-bit Digital Signal Processing 
  • Software: MXP v 2.2 
  • Overall Analysis Range:5-40 micron particle size 
  • Sample Volume: 25-500 microliters 
  • Weight: 187 lbs 
  • Width: 5 inches 
Learn More
Beckman-Coulter-FC-500-Flow-Cytometer-20487
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Flow Sciences FS 10550 M Transfer StationImage Coming Soon

Flow Sciences FS 10550 M Transfer Station

Cambridge ID #: 6252

Description:

In the 10050 Series of Bulk Powder Chemical Transfer Stations, the HEPA filtration system is housed on top of the acrylic enclosure. This filtering configuration provides maximum containment while minimizing space and energy demands. The turbulence free airflow provides a stable working environment that prevents balance fluctuations. The base of the unit is roomy enough for larger balances and comes with a standard 20” (50.8 cm) diameter cutout in the base to accommodate a large drum. Multiple filtering options are available including HEPA with 99.99% efficiency. Each system comes equipped with a face velocity alarm to continuously monitor airflow.

Specifications:

  • Dimensions (W x D x H): 59.75” x 30” x 30” (151.8 x 76.2 x 76.2 cm)
  • Weight: 305 lbs. (138.4 kg)
Learn More
Flow-Sciences-FS-10550-M-Transfer-Station-6252
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Esco LHS-8CS-F9  Laminar Flow Hood

Esco LHS-8CS-F9 Laminar Flow Hood

Cambridge Scientific ID #'s: 19169, 19168, 16695, 16696

Specifications:

  • Stainless Steel Side Walls
  • Energy Efficient ECM blower
  • 115VAC, 60 Hz
  • Simple Switches & Minihelic Gauge
  • 8ft Wide
Learn More
Esco-LHS-8CS-F9-Laminar-Flow-Hood-19169
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Nuaire NU-301-436 Laminar Flow Hood

Nuaire NU-301-436 Laminar Flow Hood

Cambridge ID #: 20660

Features:

NuAire Horizontal Laminar Flow Clean Workstations utilize the newest technologies in laminar airflow design, materials and manufacturing processes. The clean workstation can be used where clean airflow per ISO 14644-1 is required for the preparation of injectable drugs, IV solutions, tissue culture, optics, microelectronics, etc. The clean bench should not be used for any work that involves biological agents assigned a level of Risk 1 through 4 as classified by the Centers for Disease Control (CDC), Atlanta, Georgia, since the horizontal flow offers no personnel protection against these agents. The clean bench should only be used to protect the product from contamination. A significant number of design innovations give the NuAire Laminar flow equipment superior performance qualities in airflow, lighting, noise levels and vibration.

Specifications:

  • Cabinet Width (ft): 4

  • Height (in): 36

  • Filter Weight(lbs): 350

Learn More
Nuaire-NU-301-436-Laminar-Flow-Hood-20660
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1310A HPLC Isocratic Pump

Agilent 1100 Series - G1310A HPLC Isocratic Pump

Cambridge ID #: 14776

The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

 

 Features:

  • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
  • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
  • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
  • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

 

Specifications:

  • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
  • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
  • Flow range: 2 – 10.0 ml/min
  • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
  • Operating voltage: 230V

 

Learn More
Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 9165, 14496, 21293, 15507, 16000

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-9165
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1311B HPLC Quaternary Pump

Agilent 1100 Series - G1311B HPLC Quaternary Pump

Cambridge ID #: 19933

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311B-HPLC-Quaternary-Pump-19933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 12471, 16041, 17969, 13408, 16314, 16001, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1322A HPLC Degasser

Agilent 1100 Series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 15935, 13139, 13931, 20698, 15628, 14953, 17973

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1100-Series---G1322A-HPLC-Degasser-15935
By clicking below we can further assist you with your inquiry. Inquire 7 In Stock Worldwide Shipping
Agilent 1100 Series - G1361A HPLC Preparative Pump

Agilent 1100 Series - G1361A HPLC Preparative Pump

Cambridge Scientific ID #'s: 18544, 18566, 18543

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry

 

Can be sold as an individual component or as part of a complete stack

 

Learn More
Agilent-1100-Series---G1361A-HPLC-Preparative-Pump-18544
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping