Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Cell Counters and Particle Counters as well as Particle Sizers. Some of our leading manufacturers include Beckman Coulter, Roche and Malvern.

NanoDrop 2000: 46-59 of 59

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Benchmark Scientific MyFuge C1008-P *NEW* Microcentrifuge

Benchmark Scientific MyFuge C1008-P *NEW* Microcentrifuge

Cambridge Scientific ID #'s: 22494, 22495

Features:

The new MyFUGE™ Mini centrifuge is a personal centrifuge that virtually fits in the palm of your hand. Ideal for quick spin downs of microtubes and PCR tubes, the MyFuge is extremely easy to use. Simply close the lid and the rotor instantly reaches 6,000 rpm. Open the lid, and the rotor quickly decelerates to a stop for removing samples.

An increased capacity, eight-position microtube rotor is included and comes installed. A second rotor for 0.2ml PCR tubes and strips is also included and stored with the rotor removal key in a convenient compartment on the bottom of the centrifuge. When the rotor is not in use, storage in this compartment prevents loss or misplacement of the rotor.

Specifications:

  • Capacity: 8 x 1.5/2.0 mL tubes, 16 x 0.2 mL PCR tubes, 2 x 0.2 mL PCR strips
     
  • Speed: 6000 rpm / 2000 xg
     
  • Power Supply: 100 to 240 VAC, 50-60Hz

 

Learn More
Benchmark-Scientific-MyFuge-C1008-P-*NEW*-Microcentrifuge-22494
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Benchmark Scientific MyFuge C1008-R *NEW* Microcentrifuge

Benchmark Scientific MyFuge C1008-R *NEW* Microcentrifuge

Cambridge ID #: 22492

Features:

The new MyFUGE™ Mini centrifuge is a personal centrifuge that virtually fits in the palm of your hand. Ideal for quick spin downs of microtubes and PCR tubes, the MyFuge is extremely easy to use. Simply close the lid and the rotor instantly reaches 6,000 rpm. Open the lid, and the rotor quickly decelerates to a stop for removing samples.

An increased capacity, eight-position microtube rotor is included and comes installed. A second rotor for 0.2ml PCR tubes and strips is also included and stored with the rotor removal key in a convenient compartment on the bottom of the centrifuge. When the rotor is not in use, storage in this compartment prevents loss or misplacement of the rotor.

Specifications:

  • Capacity: 8 x 1.5/2.0 mL tubes, 16 x 0.2 mL PCR tubes, 2 x 0.2 mL PCR strips
     
  • Speed: 6000 rpm / 2000 xg
     
  • Power Supply: 100 to 240 VAC, 50-60Hz

 

Learn More
Benchmark-Scientific-MyFuge-C1008-R-*NEW*-Microcentrifuge-22492
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Scientific mySPIN 6 MicrocentrifugeImage Coming Soon

Thermo Scientific mySPIN 6 Microcentrifuge

Cambridge Scientific ID #'s: 22080, 22083, 22079, 22078, 22082

Specifications:

 

  • Max capacity: 6 x 2 mL
  • Max speed: 6000 rpm
  • Max RCF: 2000 x g
  • Dimensions: 5” x 6” x 4.1” (W x D x H)
  • Weight: 1.6 lbs 
Learn More
Thermo-Scientific-mySPIN-6-Microcentrifuge-22080
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Shimadzu Prominence Rack Changer/C HPLC Rack Changer

Shimadzu Prominence Rack Changer/C HPLC Rack Changer

Cambridge ID #: 13704

The chilled rackchanger unit exchanges the microplates on autosampler racks to enable samples to be continuously analyzed. 12 plates can be mounted inside the main unit and stored under refrigerated conditions.

 

Specifications:

  • Method: Variable sample injection volume and total volume direct injection
  • Injection Volume Range: 0.1 µL to 100 µL (0.1 µL to 2000 µL with option)
  • Number of Samples Processed:
    • 175 (1-mL vials), 105 (1.5-mL vials), 50 (4-mL vials),
    • 192 (two 96-well MTP/DWP), 768 (two 384-well MTP/DWP)
    • *Twelve 96-well MTP/DWP in the rackchanger
  • Injection Volume Precision: Max RSD 0.3 % (under specified conditions)
  • Cross-Contamination: Max 0.005 % (naphthalene and chlorhexidine)
  • Needle Rinsing: Freely settable, before or after sample injection
Learn More
Shimadzu-Prominence-Rack-Changer-C-HPLC-Rack-Changer-13704
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Apelex PS304 Electrophoresis Power SupplyImage Coming Soon

Apelex PS304 Electrophoresis Power Supply

Cambridge ID #: 8743

Specification:

  • Volt range: 1 - 300 Volts; 1 Volt step
  • Current range: 1 - 400 mA; 1mA step
  • Power: 0.6 - 120 Watts
  • Mode of operation: Continuous
  • Switching frequency: 23 kHz
  • Output regulation stability: ± 0,2% FS ± 1/2 digit
  • Minimum output: 1 Volts; 15 µA; 0.6 Watts
  • Value display accuracy: ± 0.2 FS ± 1/2 digit
  • Earth leakage Detection level: 500 µA
  • Output to earth impedance: 10 MΩ min bypassed by 1 nF max
  • Dimensions (D x W  x H): 24 cm x 17 cm x 11 cm
  • Weight: 1.8 kg
  • Altitude: up to 2000 m
  • Temperature: 10°C - 40°C
Learn More
Apelex-PS304-Electrophoresis-Power-Supply-8743
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
USA Scientific SD Microcentrifuge

USA Scientific SD Microcentrifuge

Cambridge ID #: 17066

Designed to reach top speeds quickly and efficiently and is ideal for spinning fluid down from tube caps and walls. The centrifuge can be operated with the on and off switch or by opening and closing the lid.

Specifications:

 

  • Speed: 6000 RPM
  • Capacity: 1.5/2.0 mL tubes
  • Dimensions: 5" x 6" x 5" in (W x D x H)
  • G-force: 2000 xg
Learn More
USA-Scientific-SD-Microcentrifuge-17066
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Baker SG-403 Biosafety Cabinet

Baker SG-403 Biosafety Cabinet

Cambridge Scientific ID #'s: 5455, 7185, 17463

Baker SterilGUARD III Advance SG403 Safety Cabinet Specifications:

Exterior Dimensions (not including stand): 53”(W) x 30” (D) x 58” (H)
Interior work surface dimensions: 46” (W) x 25” (D) x 27.5 (H)
Weight: Approx. 525 lbs
Weight with Optional Stand: 625 lbs
 
Electrical Specifications:
 
Blower Motor (1,625 RPM): 6.6 amps
Fluorescent Light (ballast): 0.8 amps
Duplex Outlets (G.F.I): 5.0 amps
Total Running Load: 12.4 amps
 
Environmental Conditions:
Altitudes up to 2000 meters
Temperature range from 5° C to 40° C
Relative humidity up to 80%
Main supply voltage fluctuations not to exceed ±10% of the nominal voltage
 
Features:
• 4’ Class II, Type A2
• Stainless Steel Work Area
• Sliding Glass Door
• Lighted Work Area
• Magnehelic Gauge
• Internal Blower
• UV Light Optional
• Includes Stand
Learn More
Baker-SG-403-Biosafety-Cabinet-5455
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Shimadzu SIL-HTC HPLC Autosampler

Shimadzu SIL-HTC HPLC Autosampler

Cambridge ID #: 22317

To be used with a Shimadzu 10 HPLC System

 

Specifications:

  • Sample injection system: Total sample injection, variable sample injection system (zero sample loss during injection)
  • Settable range of injection volumes: to 100 µL (standard), or 1 to 2000 µL (option) (0.1µL steps from 0.1 to 0.9µL, and 1µL steps from 1 to 2000 µL)
  • Sample processing capability:
    • With 1-mL vials: 350
    • With 1.5-mL vials: 140
    • with 4-mL vials:100
    • With micro plates: 4 (96 wells: 284, 284 wells: 1536)
    • with deep well plates: 4 (96 wells: 284, 284 wells: 1536)
  • Injection volume repeatability: RSD: 0.3% max. (at 10µL injection)
  • Cross contamination: 01% max. (for analysis of naphthalene)
  • Injection  volume accuracy:Less than +/- 1% (50µL)
  • Injection volume accuracy correction: Possible
  • of injections: 1-99 times per sample
  • Setting of analysis time: .01– 9999.9 (0.1 minute increments to 999.99 min., 0.1 minutes increments over 1000 min.)
  • Number of steps for injection conditions: Max 102 steps
  • Sample suction speed: 1-15 µL/sec (0.1µL/s step for 0.1-0.9 µL/sec., 1µL/s step for over1 µL/sec.)
  • Rinsing liquid suction speed: 1-35 µL/sec/ (1µL/s step)
  • Maximum pressure: 20.0 Mpa (standard pippings of sample flowpath is PEEK)

Sample cooler (SIL-HTc only)

  • Method: Direct cooling method (at a setting of 4 deg. C, room temperature must be less than 30 deg. Cand humidity less than 70%)
  • Temperature setting range: 4 to 40 deg. (cooling down to 4 deg. C for room temperature up to 30 deg. C and humidity to 70%)
  • Operating ambient temperature range:4 to 35 deg. C
Learn More
Shimadzu-SIL-HTC-HPLC-Autosampler-22317
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific Sprout Microcentrifuge

Fisher Scientific Sprout Microcentrifuge

Cambridge Scientific ID #'s: 16250, 16678

Specifications:

  • Max speed: 6,000 rpm
  • Max RCF: 2000 x g
  • Dimensions: 153x128x104mm
  • Capacity: 6-place rotor for 1.5/2 mL tubes
Learn More
Fisher-Scientific-Sprout-Microcentrifuge-16250
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Excelitas X-Cite 120  Microscope LED Fluorescence Light Source

Excelitas X-Cite 120 Microscope LED Fluorescence Light Source

Cambridge ID #: 15331

Includes: Collimating adaptor, Liquid Light Guide

Also Available Used: $2500 without Collimating Adapter

 

Also ask us about replacement Accessories such as Light Guides and Lamps!

 

 

Features

  • Pre-aligned lamp
  • 2000 hour lamp life, guaranteed
  • Powerful 120W lamp
  • Intelli-Lamp technology
  • Optional adjustable iris

 

Benefits

  • Easy lamp replacement; no alignment required
  • Fewer lamp replacements saves time and money
  • Rich spectrum with high excitation intensity
  • Maintains optimum lamp temperature, automatically accumulates lamp hours
  • Minimize photobleaching by adjusting the light intensity of the microscope illumination system

 

Specifications

  • X-Cite 120Q Microscope Illumination System includes: Lamp module, 1.5mm liquid light guide with wide-field fluorescence microscope adaptor, grounded and shielded power cord, and manual
  • Lamp: Proprietary 120W Mercury Vapor Short Arc
  • Lamp Life: 2000 hours guaranteed; 2500 hours typical
  • Power Supply: High efficiency, switch mode, line isolated, 90-264 VAC, 47-63 Hz, universal input
  • Warm-Up Period: 90 seconds (typical)
  • Panel Controls: Power On/Off, intensity adjustment (if applicable)
  • Panel Displays: Accumulated lamp usage, lamp status indicators
  • Dimensions (LxWxH): 5″ x 5.5″ x 6.5″ (34.2cm x 13.9cm x 16.5cm)
  • Weight: 7 lbs. (3.04 kg)
  • Worldwide Certifications: CE Marked, Certified to IEC, Canadian and US Standards
  • Warranty: 1 year (excluding lamp and light guide)
  • Adaptors: Compatible with wide-field fluorescence microscopes from all major manufacturers
Learn More
Excelitas-X-Cite-120-Microscope-LED-Fluorescence-Light-Source-15331
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
EXFO X-Cite 120 Microscope Metal Halide Fluorescence Light Source

EXFO X-Cite 120 Microscope Metal Halide Fluorescence Light Source

Cambridge Scientific ID #'s: 15921, 17260

Includes: Collimating adaptor, Liquid Light Guide

Also Available Used: $2500 without Collimating Adapter

 

Also ask us about replacement Accessories such as Light Guides and Lamps!

 

 

Features

  • Pre-aligned lamp
  • 2000 hour lamp life, guaranteed
  • Powerful 120W lamp
  • Intelli-Lamp technology
  • Optional adjustable iris

 

Benefits

  • Easy lamp replacement; no alignment required
  • Fewer lamp replacements saves time and money
  • Rich spectrum with high excitation intensity
  • Maintains optimum lamp temperature, automatically accumulates lamp hours
  • Minimize photobleaching by adjusting the light intensity of the microscope illumination system

 

Specifications

  • X-Cite 120Q Microscope Illumination System includes: Lamp module, 1.5mm liquid light guide with wide-field fluorescence microscope adaptor, grounded and shielded power cord, and manual
  • Lamp: Proprietary 120W Mercury Vapor Short Arc
  • Lamp Life: 2000 hours guaranteed; 2500 hours typical
  • Power Supply: High efficiency, switch mode, line isolated, 90-264 VAC, 47-63 Hz, universal input
  • Warm-Up Period: 90 seconds (typical)
  • Panel Controls: Power On/Off, intensity adjustment (if applicable)
  • Panel Displays: Accumulated lamp usage, lamp status indicators
  • Dimensions (LxWxH): 5″ x 5.5″ x 6.5″ (34.2cm x 13.9cm x 16.5cm)
  • Weight: 7 lbs. (3.04 kg)
  • Worldwide Certifications: CE Marked, Certified to IEC, Canadian and US Standards
  • Warranty: 1 year (excluding lamp and light guide)
  • Adaptors: Compatible with wide-field fluorescence microscopes from all major manufacturers
Learn More
EXFO-X-Cite-120-Microscope-Metal-Halide-Fluorescence-Light-Source-15921
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Excelitas X-Cite 120 PC Q *New* Microscope Metal Halide Fluorescence Light Source

Excelitas X-Cite 120 PC Q *New* Microscope Metal Halide Fluorescence Light Source

Cambridge ID #: 11419

Includes: Collimating adaptor, Liquid Light Guide

 

Also ask us about replacement Accessories such as Light Guides and Lamps!

 

Features

  • Pre-aligned lamp
  • 2000 hour lamp life, guaranteed
  • Powerful 120W lamp
  • Intelli-Lamp technology
  • RS-232 communication
  • Standard adjustable iris
  • Software interface
  • Foot pedal

 

Benefits

  • Easy lamp replacement; no alignment required
  • Fewer lamp replacements saves time and money
  • Rich spectrum with high excitation intensity
  • Maintains optimum lamp temperature, automatically accumulates lamp hours
  • Minimize photobleaching by adjusting the light intensity of the microscope illumination system
  • PC control of lamp, iris and shutter; integrate into automated system
  • Minimize photobleaching by adjusting light intensity
  • Hands-free operation
  • Simple to use

 

Specifications

  • X-Cite 120PC Q Microscope Illumination System includes: Lamp module, liquid light guide, software CD, grounded and shielded power cord, 9-pin serial cable, manual and quick start guide
  • Lamp: Proprietary 120W Mercury Vapor Short Arc
  • Lamp Life: 2000 hours guaranteed; 2500 hours typical
  • Power Supply: High efficiency, switch mode, line isolated, 90-264 VAC, 47-63 Hz, universal input
  • Warm-Up Period: 90 seconds (typical)
  • Panel Controls: Power On/Off, Mode Select, Adjust Up/Down, Start/Stop
  • Panel Displays: Iris setting (100%, 50%, 25%, 12%, 0%), accumulated lamp hours, exposure time (0.2-999.9 sec), lamp on, shutter open, lamp warm up, lamp/shutter status messages
  • Dimensions (LxWxH): 5″ x 5.5″ x 6.5″ (34.2cm x 13.9cm x 16.5cm)
  • Weight: 7 lbs. (3.18 kg)
  • Worldwide Certifications: CE Marked, Certified to IEC, Canadian and US Standards
  • Adaptors: Compatible with wide-field fluorescence microscopes from all major manufacturers

 

Learn More
Excelitas-X-Cite-120-PC-Q-*New*-Microscope-Metal-Halide-Fluorescence-Light-Source-11419
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Excelitas X-Cite 120 Q *New* Microscope Metal Halide Fluorescence Light Source

Excelitas X-Cite 120 Q *New* Microscope Metal Halide Fluorescence Light Source

Cambridge ID #: 10971

Includes: Collimating adaptor, Liquid Light Guide

Also Available Used: $2500 without Collimating Adapter

 

Also ask us about replacement Accessories such as Light Guides and Lamps!

 

 

Features

  • Pre-aligned lamp
  • 2000 hour lamp life, guaranteed
  • Powerful 120W lamp
  • Intelli-Lamp technology
  • Optional adjustable iris

 

Benefits

  • Easy lamp replacement; no alignment required
  • Fewer lamp replacements saves time and money
  • Rich spectrum with high excitation intensity
  • Maintains optimum lamp temperature, automatically accumulates lamp hours
  • Minimize photobleaching by adjusting the light intensity of the microscope illumination system

 

Specifications

  • X-Cite 120Q Microscope Illumination System includes: Lamp module, 1.5mm liquid light guide with wide-field fluorescence microscope adaptor, grounded and shielded power cord, and manual
  • Lamp: Proprietary 120W Mercury Vapor Short Arc
  • Lamp Life: 2000 hours guaranteed; 2500 hours typical
  • Power Supply: High efficiency, switch mode, line isolated, 90-264 VAC, 47-63 Hz, universal input
  • Warm-Up Period: 90 seconds (typical)
  • Panel Controls: Power On/Off, intensity adjustment (if applicable)
  • Panel Displays: Accumulated lamp usage, lamp status indicators
  • Dimensions (LxWxH): 5″ x 5.5″ x 6.5″ (34.2cm x 13.9cm x 16.5cm)
  • Weight: 7 lbs. (3.04 kg)
  • Worldwide Certifications: CE Marked, Certified to IEC, Canadian and US Standards
  • Warranty: 1 year (excluding lamp and light guide)
  • Adaptors: Compatible with wide-field fluorescence microscopes from all major manufacturers
Learn More
Excelitas-X-Cite-120-Q-*New*-Microscope-Metal-Halide-Fluorescence-Light-Source-10971
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Beckman Coulter Z2 Particle Counter

Beckman Coulter Z2 Particle Counter

Cambridge ID #: 12488

The Z2 COULTER COUNTER is the latest addition to the Z Series COULTER COUNTER. In addition to reporting both count and concentration results, the Z2 adds the ability to provide size distribution of the cell population. The Z2, like the Z1, uses the Coulter Principle (Electrical Sensing Zone Method) of counting and sizing of cells. This technique provides accuracy, speed, versatility and reproducibility. The Z2 displays the entire size distribution graph, or the size statistics and counts between user selectable areas of the graph. In addition, this instrument displays the cumulative count and the cumulative number % above and below a size determined by the cursor positioned on the graph. Additional Benefit, Averaging Data The Z2 has the ability to average counts and channelized data from a series of up to 10 consecutive analyses. The more cells counted and sized the greater the statistical confidence in the result and the smoother the shape of the averaged size distribution.

 

Includes:

  • Control Panel/Keyboard
  • 100 micron aperture
  • All Necessary Cords, Cables
  • Manual

 

Performance Specifications

  • Mercury Free
  • Sample result averaging
  • Size distribution graph and tabular data
  • Small Footprint
  • One-Button Calibration
  • User test functions built-in
  • Storage of up to 5 instrument settings for different cell lines
  • Technology defined by the International Standard (ISO 13319:2000: Determination of particle size distributions -- Electrical sensing zone method)
Learn More
Beckman-Coulter-Z2-Particle-Counter-12488
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping