We offer an assortment of refurbished and used Spectrometers / Spectrophotometers ranging from Spectrofluorometer, Fluorescence, Atomic Absorption (AA), ICP, to UV / Vis / NIR Spectrometers and Microplate. Some of our popular manufacturers include Beckman, Perkin Elmer, HP, Hitachi, Varian and Bio-Tek. We have one of the largest inventories of Mass Spectrometers available. We also offer service contracts, installation and training. Browse our inventory of used mass spec products below.

Spectrometers & Spectrophotometers: 1-15 of 52

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Thermo Nicolet 6700 FT-IR Spectrophotometer

Thermo Nicolet 6700 FT-IR Spectrophotometer

Cambridge ID #: 12762

Includes:

  • NXR FT-Raman Accessory Module )1064 nm Laser)
  • Raman InGaAs Detector
  • Nicolet/Nexus Series Sample Compartment Cover
  • 180 Degree Reflective Sample Comp Dual Motor Assembly
  • Raman Capillary Tube Holder
  • FT Raman MicroStage
  • Computer Loaded w/ Atlus Software, and FTIR Software

 

 

Nicolet FT-IR spectrometers from Thermo Electron Corporation are the highest performance FT-IR systems available. While the spectrometer has the power to handle the most advanced research-level experiments, routine analyses are performed just as conveniently.  Every facet of the Nicolet FT-IR spectrometer has been engineered to facilitate sample handling, introduce options to scientists, and increase laboratory throughput.

 

Specifications:

  • Spectral Range (Standard): 7800 – 350 cm-1
  • Spectral Range (Option, CsI Optics): 6400 – 200 cm-1
  • Spectral Range (Option, Extended-Range Optics): 11000 – 375 cm-1
  • Spectral Range (Option, Multi-Range Optics): 27000 – 15 cm-1 (Standard)
  • Optical Resolution: 09 cm-1
  • Peak-To-Peak Noise (1 minute scan): < 8.68 x 10^-6 AU** (50,000:1)
  • RMS Noise (1 minute scan): < 1.95 x 10-6 AU**
  • Ordinate Linearity: 07 %T
  • Wavenumber Precision: 01 cm
  • Slowest Linear Scan Velocity: 0.158 cm/sec
  • Fastest Linear Scan Velocity: 33 cm/sec
  • Number of Scan Velocities: 15
  • Rapid Scan (Spectra/second @ 16 cm-1, 16 cm-1: 65, 95
  • Throughput Increase in Turbo Mode (@ 3000 cm: 25%
  • Liquid Nitrogen-Cooled Detector Hold Time: 18 hours
Learn More
Thermo-Nicolet-6700-FT-IR-Spectrophotometer-12762
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 8453 HPLC UV/VIS Detector

Agilent 8453 HPLC UV/VIS Detector

Cambridge ID #: 20107

System Includes:

  • Agilent G1103A UV-Vis Spectrophotometer
  • G1115AA/BA Spectral B.04.xx 32 Bit Chemstation Software or C.01.xx OpenLab Software (your choice)
  • Computer With Windows 7 Pro or Windows XP Operating System
  • Cables and Accessories

Specifications:

  • Wavelength range: 190–1100 nm
  • Slit width: 1 nm
  • EP resolution test: > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm
  • Stray light:
    • < 0.03 % at 340 nm (NaNO2, ASTM)
    • < 0.05 % at 220 nm (NaI, ASTM)
    • < 1 % at 198 nm (KCl, EP)
  • Wavelength accuracy:
    • < ± 0.5 nm 0.5-second scan (NIST 2034)
    • < ± 0.2 nm at 486.0 and 656.1 nm
  • Wavelength reproducibility: < ± 0.02 nm ten consecutive scans (NIST 2034)
  • Photometric accuracy:
    • < ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)
    • < ± 0.01 A at 235, 257, 313, 350, 430 nm, (potassium dichromate, EP method)
  • Photometric noise: < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms
  • Photometric stability: < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp.
  • Baseline flatness: < 0.001 A 0.5-second blank, 0.5-second scan, rms
  • Typical scan time: 5 second full range
  • Shortest scan time: 1 second full range
  • Time until next scan: 1 second full range, 0.1-second scan, up to 150 consecutive scans
Learn More
Agilent-8453-HPLC-UV-VIS-Detector-20107
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21357

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21357
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3F *NEW* Atomic Absorption Spectrophotometer

Persee A3F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21355

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3F-*NEW*-Atomic-Absorption-Spectrophotometer-21355
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3G *NEW* Atomic Absorption Spectrophotometer

Persee A3G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21356

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3G-*NEW*-Atomic-Absorption-Spectrophotometer-21356
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21354

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21354
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21352

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21353

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990G-*NEW*-Atomic-Absorption-Spectrophotometer-21353
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity QDa Mass Detector

Waters Acquity QDa Mass Detector

Cambridge ID #: 20856

ACQUITY QDa is as intuitive as an optical detector, with the robustness to handle all of your analyses. Working in harmony with your chromatography, it is pre-optimized to work with your samples, without the sample-specific or user adjustments typical of traditional mass spectrometers. For the first time, any analytical scientist can consistently generate the highest quality mass spectral data, routinely without the need for any special training or expertise thus eliminating any need to contract out and wait for results from specialist analytical service laboratories.

With ACQUITY QDa Detector, you can minimize the risk of unexpected coelutions or components and you can confirm trace components with certainty because of the analytical confidence that mass detection brings. Enhance the analytical value and productivity of each analysis, eliminating the need to run all the additional assays or time-consuming alternative techniques.

Working in synergy with optical detection, you can significantly reduce the chance that a sample component will go undetected.

The ACQUITY QDa Detector is compatible with all Waters ACQUITY UPLC, ACQUITY UPC2, Alliance HPLC, and purification LC and SFC systems. The ACQUITY QDa Mass Detector is complementary to your current Waters optical detectors including ACQUITY UPLC PDA, TUV, or FLR, or ACQUITY UPCPDA optical detectors.

The mass spectral information combines seamlessly into the same workflow, routinely giving you more complete characterization of your separation.

Process, interpret, visualize, and compare the most complex data, and turn it into meaningful information quickly and simply. The ACQUITY QDa Detector is fully compatible with Empower Software, our industry-leading chromatography data software platform.

With integrated optical and mass detector data processing workflows, you can also interrogate mass spectral data in the same way and same workflow as you do PDA data. The ACQUITY QDa Detector is also fully compatible with MassLynx Software and its suite of Application Managers.

Learn More
Waters-Acquity-QDa-Mass-Detector-20856
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bruker AMX-300 NMR System

Bruker AMX-300 NMR System

Cambridge ID #: 18992

Bruker AMX-300 Nuclear Magnetic Resonance Spectrometer with the "piano" style console and an unshielded Oxford 300MHz magnet. The magnet was de-energized about five years ago. All of the kits for moving the magnet are included.  

This is a 2-channel system with a solids accessory rack with high power 1H and X transmitters. Three probes included (plus a Doty solid state probe): a 5mm 1H inverse probe, a 10mm BB, and a standard bore magic angle solids probe (7 & 4mm stators).  

Learn More
Bruker-AMX-300-NMR-System-18992
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 BioPhotometer D30

BioPhotometer D30

Cambridge ID #: 21660

Features:

The Eppendorf BioPhotometer D30 is the third generation of the well-established line of Eppendorf BioPhotometers, also known as detection instruments or photometers. The compact instrument clearly processes data, records at fixed wavelengths and makes evaluating results fast and simple. For specific methods, additional measurements are recorded and displayed as a graph, making impurities easier and quicker to identify. 

Specifications:

 

  • Absorption measuring range: 0A - 3.0A (260 nm)
  • Cuvette shaft: 12.5 x 12.5 mm
  • Light source: Xenon flash lamp
  • Wavelengths: 230, 260, 280, 320, 340, 405, 490, 562, 595, 600 nm
  • Dimensions: 11.6 x 15.7 x 6” (295 x 400 x 150 mm)
  • Weight: 11.9 lbs (5.4 kg)
Learn More
-BioPhotometer-D30--21660
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer

Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer

Cambridge ID #: 20111

This Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer was never installed and is unused in storage.

Specifications:

Frequency Controller & Signal Generation Unit

  • Basic configuration two channels frequency range each channel: 5–650 MHz each
  • Number of numerically controlled oscillators per channel: 3
  • Frequency resolution: < 0.005 Hz
  • Phase resolution: < 0.006º
  • Attenuation resolution / attenuation range: < 0.1 dB / 90 dB
  • Amplitude modulation: > 90 dB
  • Event time for digital setting of frequency, phase and amplitude, either individually or simultaneously: 25 ns
  • Memory per channel e.g. for pulse shaping: >8 Mbyte
  • Phase monotony over 90 dB amplitude setting range: < + / - 0.5 º

Timing Controller

  • Pulse sequence parameter calculation: in real time
  • Timing resolution / min. duration:5 / 25 ns
  • Output bus for events and devices: 96-bit

Communication Protocol

  • Fast Ethernet TCP / IP

Host Computer

  • Operating system: Windows 7

Receiver:

  • Bandwidth: up to 5 MHz

Digital Receiver Unit (DRU)

  • Effective dynamic range of digitizer
  • SW < 5 MHz: > 16-bit
  • SW < 1 MHz: > 18-bit
  • SW < 6 kHz: > 22-bit
  • Data compression / digital filtering: on the fly
  • Optimum real time digital filters: Yes

Quadrature Receiver (RXAD):

  • Quadrature image peaks with digital quadrature detection: 0%
Learn More
Bruker-BioSpin-Avance-III-HD-400-High-Performance-Digital-NMR-Spectrometer-20111
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Cary Eclipse Fluorescence Spectrophotometer  Fluorescence Spectrophotometer

Agilent Cary Eclipse Fluorescence Spectrophotometer Fluorescence Spectrophotometer

Cambridge ID #: 21019

Features:

  • Multiple collection modes: Fluorescence, phosphorescence, chemi/bio-luminescence, and time resolved phosphorescence measurements can all be easily made without changing a single hardware component
  • Lowest cost of ownership: The Cary Eclipse is so robust and reliable that every new instrument comes with a 10-year lamp life guarantee, reducing ongoing expenses to virtually zero. 
  • Improved laboratory safety: Additionally the guaranteed exceptionally long lifetime of the lamp in the Cary Eclipse eliminates lamp replacements, a hugely time-consuming and potentially hazardous operation.
  • Easy to use: Modular, application-specific software, which satisfies the needs of novice and expert users alike, and the ability to switch between measurement modes without touching the hardware, ensure that any user can quickly get reliable, accurate results with minimal training.
  • Expand your analytical capabilities: The superior, unique design of the Cary Eclipse ensures room light immunity allowing the instrument to operate with the front and top panels removed for easy access to sample and fast installation of large accessories.
  • Proven sensitivity where you need it most: Optimized design coupled with unique, high-sensitivity optics and detectors ensure that the Cary Eclipse gives you the performance that you need right across the spectrum. 
  • Robustness, reliability and sensitivity: Engineered to be the most robust instrument on the market, the Cary Eclipse incorporates the unique Agilent xenon flash lamp to capture a data point every 12.5 ms and scans at 24,000 nm/min without peak shifts perfect for high throughput laboratories and fast kinetics applications.
  • Unique Sampling: By incorporating Agilent’s unique capacity to guarantee room light immunity coupled with the highly accurate and reproducible Peltier temperature control, the Cary Eclipse delivers unique sampling opportunities that will expand your analytical capabilities, simplify your workflow and increase your sample throughput.
  • Reliable Results: The Cary Eclipse only illuminates the sample when data is actually being acquired. This means that the Cary Eclipse prevents your valuable samples from photodegradation and preserves their integrity to the point that you can measure them over and over again and continue to get the same, reliable result. 

Specifications:

  • Dimensions(WxDxH): 60 x 64 x 27 cm (23 x 25 x 10 inches)
  • Sensitivity:> 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
  • Wavelength(s):190 - 1100 nm
  • Temperature Range: 10 – 35°C
  • Optical System: Cerny-Turner 0.125 m Monochromators
  • Light Source: Xenon Flash Lamp
  • Software: Cary Eclipse Software
Learn More
Agilent-Cary-Eclipse-Fluorescence-Spectrophotometer-Fluorescence-Spectrophotometer-21019
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek Epoch Microplate UV/VIS Reader

BioTek Epoch Microplate UV/VIS Reader

Cambridge ID #: 21529

Features:

Epoch Microplate Spectrophotometer includes monochromator-based optics that provides filter-free, wide wavelength range for UV-Vis absorbance measurements in various microplate formats. This spectrophotometer is controlled by Gen5 Software that allows intricate data analysis, yet simple programming. This product is cost-effective and requires low maintenance.

Specifications:

General:

  • Detection modes: Absorbance
  • Read methods: Endpoint, kinetic, spectral scanning, well area scanning
  • Microplate types: 6- to 384-well plates
  • Other labware supported: Take 3 Micro-Volume Plates


Absorbance:

  • Light source: Xenon flash
  • Detector: photodiode
  • Wavelength selection: monochromator
  • Wavelength range: 200 to 999 nm, in 1 nm increments
  • Monochromator bandwidth: 5 nm
  • Dynamic range: 0 - 4.0 OD
  • Resolution: 0.0001 OD
  • Pathlength correction: yes
  • Monochromator wavelength accuracy: + 2 nm
  • Monochromator wavelength repeatability: + 0.2 nm
  • OD accuracy: 0 to 2 OD: +1% +0.010 OD , 2 to 2.5 OD: +3% +0.010 O
  • OD linearity: 0 to 2 OD: +% +0.010 OD , 2 to 2.5 OD: +3% +0.010 OD
  • OD repeatability: 0 to 2 OD: +1% +0.005 OD , 2 to 2.5 OD: +3% +0.005 OD
  • Reading speed (kinetic): 96 wells - 15 seconds | 384 wells - 31 seconds

Physical Characteristics:

  • Power: 100 - 240 Volts AC. 50/60 Hz.
  • Dimensions: 12" W x 12.5" D x 7.7" H
    (30.5 cm x 31.8 cm x 19.6 cm)
  • Weight <15 lbs (6.8 kg)
Learn More
BioTek-Epoch-Microplate-UV-VIS-Reader-21529
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek Epoch 2 Microplate UV/VIS Reader

BioTek Epoch 2 Microplate UV/VIS Reader

Cambridge ID #: 21111

Features:

Epoch™ 2 Microplate Spectrophotometer offers excellent performance for UV-Vis measurements in 6- to 384-well microplates, cuvettes and in micro-volume samples with the available Take3™ Micro-Volume Plate. The optional touchscreen interface makes it easy to choose from pre-defined protocols or to define custom programs. Endpoint, kinetic, spectral scanning and well area scanning modes, plus incubation and shaking enable wide-ranging applications.

Specifications:

  • Microplate types: 6 to 384 well plates
  • Temperature control: 4-Zone incubation to 65 °C with Condensation Control
    • Uniformity + 0.2 °C at 37 °C
  • Light source:  Xenon flash
  • Wavelength range: 200 - 999 nm, selectable in 1 nm increments
  • Monochromator bandwidth: 2.9 nm
Learn More
BioTek-Epoch-2-Microplate-UV-VIS-Reader-21111
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping