Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Autoclaves ranging from Tabletop Autoclaves, Stand Alone Autoclaves and Top Loading Autoclaves to Wall Unit Autoclaves. Some of our popular manufacturers include Tuttnauer, Market Forge, Pelton & Crane, Hiryoma and Amsco. Additionally, we sell a wide selection of Glassware Washers including Labconco, Miele and Steris.

Water Purification: 181-195 of 228

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Scican Hydrim L110W-D01 WasherImage Coming Soon

Scican Hydrim L110W-D01 Washer

Cambridge ID #: 20853

Features:

HYDRIM L110W G4 washer has a 10 full-size cassette capacity and will allow offices to turnover 2500 thoroughly cleaned instruments in a 10 hour day.
Under the counter stericentre installation with furniture available for specialized set-ups. HIPTM cleaning solution is stored in the unit, no extra storage space required
Time saved using automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups.1

 

Specifications:

Height, freestanding: 850 mm / 33.5"

Height, built-in: 830 mm / 32.75"

Width: 600 mm / 23.75"

Depth: 600 mm / 23.75"

Depth with door open: 1200 mm / 47"

Weight: 80 kg / 176 lbs.

Running Noise: 60 dB(A)

Hot and cold water connections: 3/4”

Inlet water pressure: 1-10 bar/14.5-145 psi

Incoming hot water temperature: 50-70°C / 122-158°F

Drain: 3/4”

Water softener: 1 kg / 2.2 lbs salt capacity

Drying System: Heater 1 kW

Electrical Connection: 208-240 V 60 Hz 15 A

Equipment pollution degree: Pollution Degree 2

Equipment installation category: Installation category II

Maximum relative humidity: 80% for temp up to 31°C / 88°F

50% for temp up to 40°C / 104°F

Operating temperature range: -5°C to 40°C / 23-104°F

Max. altitude: 2000m / 6561.7 ft.

Mains supply: + / -10% of nominal

Learn More
Scican-Hydrim-L110W-D01-Washer-20853
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Invitrogen Iblot 2 Dry Blot System

Invitrogen Iblot 2 Dry Blot System

Cambridge ID #: 21888

The iBlot 2 Gel Transfer Device is an integral part of the iBlot 2 Dry Blotting System, which consists of the transfer device and consumable transfer stacks that contain the required buffers and transfer membrane (nitrocellulose or PVDF)

  • Complete protein transfer in 7 minutes or less
  • High detection sensitivity and even transfer
  • Increased blotting reliability and reproducibility
  • Flexible gel size formats and membrane types
  • A simple, user-friendly system
  • Options to create new custom programs
  • Built-in tutorial and application notes
  • High-quality transfer stacks that are more compact than before

Rapid, High-quality Protein Transfers

  • For dry electroblotting of proteins from mini-, midi-, and E-PAGE™ gels onto nitrocellulose or PVDF membranes for Western detection
  • Offers high-quality transfer, convenience, and speed, producing crisp, clear bands that remain sharp and straight, with exceptional transfer efficiency
  • Allows users to create custom programs

iBlot 2 Transfers Save Time

  • With the iBlot 2 system, there is no need to prepare buffers, pretreat the gel, or clean up after blotting
  • The total preparation and run time is normally less than 10 minutes per blot for significant time savings compared to conventional Western transfer techniques

How It Works

  • Buffer ion reservoirs are incorporated into the gel matrix (transfer stacks) instead of buffer tanks or soaked papers
  • The high density of ions in the gel matrix enables rapid protein transfer
  • During blotting, the copper anode does not generate oxygen gas as a result of water electrolysis, reducing blot distortion (conventional protein transfer techniques, including wet, semi-wet, and semi-dry, use inert electrodes that generate oxygen)
  • Transfer time is reduced by the shortened distance between electrodes, high field strength, and high current
  • Trapped air bubbles, often created during the manual preparation of the blotting sandwich layers, are easy to avoid due to the de-bubbling design that promotes even and complete transfer

Proteins, Expression, Isolation and Analysis, Western Blotting

Learn More
Invitrogen-Iblot-2-Dry-Blot-System-21888
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Life Technologies iBlot 2 Dry Blot System

Life Technologies iBlot 2 Dry Blot System

Cambridge ID #: 19805

The iBlot 2 Gel Transfer Device is an integral part of the iBlot 2 Dry Blotting System, which consists of the transfer device and consumable transfer stacks that contain the required buffers and transfer membrane (nitrocellulose or PVDF)

  • Complete protein transfer in 7 minutes or less
  • High detection sensitivity and even transfer
  • Increased blotting reliability and reproducibility
  • Flexible gel size formats and membrane types
  • A simple, user-friendly system
  • Options to create new custom programs
  • Built-in tutorial and application notes
  • High-quality transfer stacks that are more compact than before

Rapid, High-quality Protein Transfers

  • For dry electroblotting of proteins from mini-, midi-, and E-PAGE™ gels onto nitrocellulose or PVDF membranes for Western detection
  • Offers high-quality transfer, convenience, and speed, producing crisp, clear bands that remain sharp and straight, with exceptional transfer efficiency
  • Allows users to create custom programs

iBlot 2 Transfers Save Time

  • With the iBlot 2 system, there is no need to prepare buffers, pretreat the gel, or clean up after blotting
  • The total preparation and run time is normally less than 10 minutes per blot for significant time savings compared to conventional Western transfer techniques

How It Works

  • Buffer ion reservoirs are incorporated into the gel matrix (transfer stacks) instead of buffer tanks or soaked papers
  • The high density of ions in the gel matrix enables rapid protein transfer
  • During blotting, the copper anode does not generate oxygen gas as a result of water electrolysis, reducing blot distortion (conventional protein transfer techniques, including wet, semi-wet, and semi-dry, use inert electrodes that generate oxygen)
  • Transfer time is reduced by the shortened distance between electrodes, high field strength, and high current
  • Trapped air bubbles, often created during the manual preparation of the blotting sandwich layers, are easy to avoid due to the de-bubbling design that promotes even and complete transfer

Proteins, Expression, Isolation and Analysis, Western Blotting

Learn More
Life-Technologies-iBlot-2-Dry-Blot-System-19805
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bran Luebbe InfraProver II NIR SpectrometerImage Coming Soon

Bran Luebbe InfraProver II NIR Spectrometer

Cambridge ID #: 13370

Description: The DO308 drying oven is ideal for accurate water determination of solid or viscous samples like:

  • Substances that release water only at elevated temperatures such as plastics in powder or granular form
  • Substances that cause side reactions with Karl Fischer reagent such as oxidizing inorganic salts
  • Substances that cause problems in the titration vessel due to their consistency such as fibrous or pasty substances
  • Substances that are poorly soluble or insoluble such as wool, dough, tar or coal

Specifications:

  • Temperature range: 40 - 300 °C
  • Temperature accuracy: ±5 °C (@300°C)
  • Footprint housing: 256 x 180 mm
  • Dimensions overall: 500 x 220 mm
  • Voltage (auto selection): 100 ... 230 VAC   
  • Max. power consumption: 450 W
  • Height: 390 mm
  • Weight: 9.1 kg

Features and Benefits

  • Easy and fast manual handling - Easy handling for left and right handed operators. Sample exchange and sample transport into the heated zone of the oven is provided for by the simple transport system with a magnetic guide rod attached to the glass sample boat.
  • Equilibrium conditions are quickly reached - The cold and the hot zone can be purged separately with dry carrier gas using a stopcock. Ambient moisture introduced during sample exchange or addition via the sleeve opening is quickly carried away. Therefore, a stable drift is reached within a short period of time.
  • Enhanced operational safety - There is no need to remove the transfer tube from the titration cell after switching off the oven; just open the stopcock to avoid contamination of the oven due to underpressure. Different temperature ranges can be pre-programmed in one cycle. Safety is further improved by automatic shut down after the analysis is completed.
  • Ready for use - All necessary parts including the drying unit with gas flow measurement are part of the standard delivery. If purging with dry air is desired, an optional air pump is available.
Learn More
Bran-Luebbe-InfraProver-II-NIR-Spectrometer-13370
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific Isotemp 3532  CO2 Incubator

Fisher Scientific Isotemp 3532 CO2 Incubator

Cambridge ID #: 20824

Features:

  • Choice of Water-Jacketed (WJ) and Direct Heat (DH) technology
  • Flexibility you can depend on for growing cells
  • Select Thermal Conductivity (T/C) or Infrared (IR) sensors to serve your applications
  • High-capacity 6.5 cu. ft. (184L) chamber
  • Heavy-duty stainless-steel shelves support a full load of samples
  • Precise temperature control and stability of all culture parameters

Specifications:

  • Temperature Range (Metric) 5°: above ambient to 60°C
  • Voltage: 120 V
  • Shelf Material: Stainless Steel
  • Width (English): 26.3 in.
Learn More
Fisher-Scientific-Isotemp-3532-CO2-Incubator-20824
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu LC-20AT HPLC Pump

Shimadzu LC-20AT HPLC Pump

Cambridge Scientific ID #'s: 22321, 22320, 22318

The LC-20AT possesses a high level of stability while maintaining high performance during routine use. The ability to remove pulsations has been improved by modifying the pump-head structure and the flow line.

Features:

  • Enhanced Solvent Delivery Specifications: Flow-rate accuracy and precision in the micro-flow rate region have been improved with the addition of a new type of check valve and modifications to the solvent delivery control method. Non-polar organic solvents such as hexane can be delivered stably.
  • Improved Durability: New and improved plunger seal materials ensure robust, long-lasting performance. A sapphire plunger optimized according to its crystal structure and a precise plunger-holding mechanism help increase the service life of plunger seals and enable stable solvent delivery over long periods.
  • Space-saving Designs: An optional low pressure gradient valve (LC-20AD/20AT), CBM-20Alite system controller, and a seal wash pump (LC-20AD) can now be installed inside the solvent delivery unit, enabling 4-solvent gradient elution in a compact space. The LC-20AB high-pressure binary gradient pump delivers the performance of two LC-20AD pumps in one compact unit.

 

Specifications:

  • Solvent delivery method: Series-type double plunger
  • Plunger capacity: Primary side: 47µL, Secondary side: 23µL
  • Maximum discharge pressure: 40MPa
  • Flow-rate setting range: 0.001 to 10.000 mL/min.
  • Flow-rate accuracy: No more than 2% or 2µL/min., whichever is greater (0.01 to 5 mL/min.)
  • Flow-rate precision: No more than 0.06% RSD or 0.02 min SD, whichever is greater
  • Pulsation: 0.3 MPa (for water at 1.0 mL/min. and 7MPa)
  • Constant-pressure solvent delivery: Supported
  • Plunger rinsing mechanism: Manual rinsing or automatic rinsing using optional product
  • Safety measures: Liquid-leakage sensor, high-pressure/low-pressure limits
  • Operating temperature range: 4oC to 35oC
  • Dimensions, weight: 260 (W) x 140 (H) x 420 (D) mm, 11 kg
  • Power requirements: 100 VAC, 150 VA, 50/60 Hz 
  • Gradient type: High-pressure mixing
  • Number of mixed solvents: 2 or 3
  • Mixing concentration accuracy: 0.5% max. (LC-20AD), 1.0% max. (LC-20AT)
Learn More
Shimadzu-LC-20AT-HPLC-Pump-22321
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Thermo Neslab M25 Recirculating ChillerImage Coming Soon

Thermo Neslab M25 Recirculating Chiller

Cambridge ID #: 15243

The Thermo Neslab Merlin M25 is a transportable, powerful, and extremely capable CFC- free chiller that provides users with an unchallenged level of dependability and versatility. The Thermo Neslab Merlin M25 Circulating has an extremely flexible temperature range. Because of its relatively small size and adaptable cooling range, the M25 Merlin is extremely well suited for both small and large laboratories. Along with an onboard LCD digital control and display, the M25 Merlin also features a precautionary temperature alarm to alert users whenever temperature thresholds are being reached.

Specifications:

  • Temperature Range:-15°C to 35°C
  • Cooling Capacity:741W, 2528 BTU/hour
  • Capacity:8 L
  • Dimensions:9 x 12.6 x 23.5 in
  • Temperature Stability:+/- 0.1°C
  • Power Requirements: 115V
a
Learn More
Thermo-Neslab-M25-Recirculating-Chiller-15243
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex 7554-90 Peristaltic Pump

Cole Parmer Masterflex 7554-90 Peristaltic Pump

Cambridge ID #: 18466

The Masterflex L/S Economy Variable-speed drive is an economical and versatile variable-speed drive with a wide flow range. This product features a separate single-turn speed control and on/off switch with green power indicator to maintain speed setting while turning pump on/off. The 1/20-hp unidirectional motor (counterclockwise) as soft start and back EMF for 5% speed control. Stackable painted steel housing is IP22 rated for protection from vertically falling water.

 

Specification:

 

  • Drive Speed Range: 20 - 600 rpm
  • Maximum Torque: 90 oz-in
  • Line Voltage Limits (50-60 Hz): 90-130 V
  • Power Output: 37 W (0.05 hp)

 

  • Maximum Current

 

    • 115 V Units: 1.5A, shorted output conditions
    • 230 V Units:  0.9A, shorted output conditions

 

  • Speed Regulation

 

    • Line: ±2%
    • Load: ±3%
    • Temperature Drift: ±10%
  • Enclosure Rating: IP22 per IEC529
  • Humidity (non-condensing): 10% to 90%
  • Operating Temperature: 0Ëš to 40ËšC
  • Storage Temperature: -45Ëš to 60ËšC
  • Chemical Resistance: Exposed material is painted steel housing
  • Altitude: Less than 2000 m
  • Display: Green LED
  • Dimensions (L x W x H): 220 x 180 x 125 mm
  • Weight: 4.1 kg (9 pounds)
  • Pollution Degree: 2 per IEC 664 (indoor use only)
  • Installation Category: 2 per IEC 664
Learn More
Cole-Parmer-Masterflex-7554-90-Peristaltic-Pump-18466
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sanyo MCO-18AIC (UV) CO2 Incubator

Sanyo MCO-18AIC (UV) CO2 Incubator

Cambridge Scientific ID #'s: 21287, 21286

Features:

  • The Sanyo MCO-18AIC CO2 Incubator features unprecedented humidity and temperature control technology, which provides both flexible and robust stability control for cultures. The new direct heat and air jacket system eliminates the inconvenient use of water in the incubator and provides heat from the door, side, and bottom of the unit. The Sanyo MCO-18AIC utilizes an infrared CO2 sensor, which is not affected by changes in humidity or temperature, maintains constant conditions via the microprocessor control, and automatically calibrates using room air temperature as reference. Also features Safe Cell UV contamination control system.

Specifications:

  • Exterior Dimensions (W x D x H): 24.4 x 28 x 35.4 in

     

  • Interior Dimensions (W x D x H): 19.3 x 20.6 x 26.2 in

     

  • Volume: 170 L

     

  • Temperature Range: 5° to 50°C

     

  • Temperature Uniformity: ±0.1°C

     

  • CO2 Range: 0 to 20%

  • CO2 Uniformity: ±0.15%

     

  • Chamber Humidity: 95±5% RH

Learn More
Sanyo-MCO-18AIC-(UV)-CO2-Incubator-21287
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Thermo Neslab Merlin M33 Recirculating ChillerImage Coming Soon

Thermo Neslab Merlin M33 Recirculating Chiller

Cambridge ID #: 19906

 

Specifications:

  • Capacity: 1.9L
  • Temperature Range: +5°C to +35°C
  • Temperature Stability:  ±0.1°C
  • Cooling Capacity at 20°C: 1250W
  • Cooling Capacity at 5°C: 490 W
  • Maximum Flow Rate (L/min): 6.75
  • Power Requirements: 115V, 60hz, 13A
Learn More
Thermo-Neslab-Merlin-M33-Recirculating-Chiller-19906
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Midi 40 CO2 Incubator

Thermo Midi 40 CO2 Incubator

Cambridge ID #: 19189

Description:

Safely and efficiently operate Thermo Scientific Midi 40 CO2 Incubators. They use the Thermo Scientific IntrLogic II microprocessor-based control system with alphanumeric setpoint display of temperature, CO2, alarm, calibration and diagnostic functions. Enhanced microprocessor-based IntrLogic II control provides comprehensive control, monitoring and display of all incubator systems for safe, efficient operation. This is a fully featured 1.4 cu. ft. (40 L) incubator occupying less than 2 sq. ft. (0.6 m2) of space.

Specifications:

  • Chamber Material: Polished stainless steel
  • CO2 Concentration Range: 0 to 20%
  • CO2 Sensor Technology: TC sensor
  • Humidity Delivery: Water Pan
  • Relative Humidity: >90% at 37°C
  • Temperature Range: Ambient +5° to 50°C
  • Data Outputs: RS485
  • Certifications/Compliance: CE, UL, cUL
  • Capacity: 1.4 cu.ft. (40 L)
  • Electrical Requirements: 120 V 60 Hz
  • Dimensions (L x W x H): 23.5 x 18.5 x 18 in. (59.7 x 47 x 46.5 cm)
  • Weight: 60 lb (28 kg)
Learn More
Thermo-Midi-40-CO2-Incubator-19189
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR Mini Stirrer 120V (10153-304) Magnetic StirrerImage Coming Soon

VWR Mini Stirrer 120V (10153-304) Magnetic Stirrer

Cambridge ID #: 19378

Description:
The VWR Mini Stirrer is a rugged, compact stirrer with an ergonomic design and can stir up to 1000mL of water.
It is energy efficient by running only when needed and stops after operation.
It is equipped with an optional support plate that allows hot plate to be mounted to lab frames or ring stands


Specifications:
⦁ Rugged 5x5" aluminum top plate
⦁ Maximum Capacity: 1000mL
⦁ Speed Range: 100 - 1200rpm
⦁ Electrical Requirements: 120V,50/60Hz

Learn More
VWR-Mini-Stirrer-120V-(10153-304)-Magnetic-Stirrer-19378
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 minichiller ChillerImage Coming Soon

minichiller Chiller

Cambridge ID #: 21998
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
-minichiller-Chiller-21998
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Tecan MiniPrep 75 Liquid Handler

Tecan MiniPrep 75 Liquid Handler

Cambridge ID #: 22443

The MiniPrep can be equipped to perform repetitive laboratory procedures in a wide range of application areas:

  • Nucleic Acid Extraction and Purification ( Solid Phase Extraction (SPE), or Magnetic Bead Separation (MBS) )
  • Mother-Daughter Plate Replication
  • ELISA Assays
  • Immunophenotyping
  • LC Injection
  • Cell-Based Assays and Separations
  • Protein Assays

Specifications:

  • Pipetting Arms: 1 or 2
  • Microplate Capacity Deck: 12
  • Footprint: (W) 815 mm (32.1") x (D) 600 mm (23.6")x (H) 515 mm (20.3")(H does not include Z-rack)
  • Probe Travel Range: (W) 643 mm (25.3") x (D) 300 mm (11.8")x (H) 165 mm (6.5") 
  • Weight: ~46 kg (100 pounds)
  • Input Voltages: Auto-selecting 110/230 VAC +/- 10%
  • Frequency: 47 - 63 Hz
  • Maximum Power: 250 Watts
  • 384 Well MTP Support: Yes
  • Diluter 1, 8 Channel: Yes
  • Disposable Tip: Yes
  • LC Injection: Yes
  • Volume Range: 0.5 µL - 25.0 mL
  • Syringe Sizes: 250 µL - 25.0 mL 
  • Accuracy: <1% @ full stroke with 1.0 mL syringe*
  • Precision: <0.05% CV @ full stroke with 1.0 mL syringe*
  • Minimal Detectable Volume: 50 µL of ionic fluid in a 96 well flat bottom standard microplate format. A minimum 1 mm of ionic liquid level height is necessary for reliable liquid detection.
  • Standard Software: Gemini Software for MiniPrep

*Accuracy and precision values determined using dilute salt solution (0.05 N NaCI). Liquid handling performance will differ depending on fluid type, tip type, tubing configuration and environmental conditions.

Learn More
Tecan-MiniPrep-75-Liquid-Handler-22443
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma Model 8890 Glassware Washer

Thermo Forma Model 8890 Glassware Washer

Cambridge ID #: 9860

Operates in three modes; electric heat, steam heat, or electric and steam heat.

Specifications:

  • Interior dimensions: 5W x 27.2T x 33.0F-B inches
  • Exterior dimensions:0W x 77.2T x 47.6F-B inches
  • Water reservoir: Holds 29 gallons of distilled water
  • Controls: Microprocessor-based programming unit
  • Programs: 9-preset programs with 10 functions each
Learn More
Thermo-Forma-Model-8890-Glassware-Washer-9860
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping