We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Agilent: 61-75 of 84

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 2100 (G2938B) Bioanalyzer

Agilent 2100 (G2938B) Bioanalyzer

Cambridge ID #: 16169

Includes:

  • Agilent G2938C Bioanalyzer
  • Computer with Bioanalyzer Software
  • Vortexer
  • Priming Station

 

The Agilent 2100 Bioanalyzer is a microfluidics-based platform for sizing, quantification and quality control of DNA, RNA, proteins and cells. Results are delivered within 30-40 minutes in automated,

high quality digital data.

 

Miniaturization of analytical instrumentation has many advantages over conventional techniques. These advantages include improved data precision and reproducibility, short analysis times, minimal sample consumption, improved automation and integration of complex workflows

 

Areas of Application:

  • On-chip flow cytometry
    • The easy way to acquire dual-color, cell-based fluorescence data
  • RNA quality check with RIN
    • The industry standard for RNA analysis offering total RNA, mRNA and Small RNA's data including RIN algorithm (RNA Integrity Number)
  • DNA size and quantity
    • Smart, high resolution separation and quantification of DNA Highly sensitive DNA sample QC for next generation sequencing experiments
  • SDS-PAGE replacement for protein analysis
    • The fast and reliable way to determine the quantity and purity of proteins from Coomassie down to silver stain sensitivity

 

Features:

  • Faster than gels – analyze 10-12 samples in 30-40 minutes
  • Easy to use – load the chip, press "start“, the instrument does the rest
  • Ready-to-use assays and pre-packaged reagent kits
  • Reproducible data, contamination-free hardware
  • Quick and easy sample comparison – one-click overlay, scaling or zooming features
  • Reproducible, complete and digital data
  • Easy handling, storage and exchange of digital data
  • Quantification of each individual fragment per sample offers purity results 2-color analysis of fluorescently stained cells
  • Data is acquired and archived in digital format.
Learn More
Agilent-2100-(G2938B)-Bioanalyzer-16169
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 35900E HPLC Interface

Agilent 35900E HPLC Interface

Cambridge Scientific ID #'s: 11228, 15239, 9312, 11227

Features:

  • Data buffering
  • Independent analog-to-digital (A/D) converters
  • Real-time control
  • Instrument control ports
  • Host communication
  • Front panel indicators that show run status, interface activity, etc.
  • Compatibility with Agilent data systems
  • External power adapter with 24V DC output
Learn More
Agilent-35900E-HPLC-Interface-11228
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 6212A Electrophoresis Power SupplyImage Coming Soon

Agilent 6212A Electrophoresis Power Supply

Cambridge ID #: 8173

Description:

This power supply is completely transistorized and suitable for either bench or relay rack operation. It is a compact, well-regulated, Constant Voltage/Constant Current supply that will furnish full rated output voltage at the maximum output current or can be continuously adjusted throughout the output range. The front panel current control can be used to establish the output current limit when the supply is used as a constant voltage source and the voltage controls can be used to establish the voltage limit when the supply is used as a constant current source. The supply will automatically crossover from constant voltage to constant current operation and vice versa if the output current or voltage exceeds these preset limits.

Specifications:

  • Voltage: 100 V
  • Current: 0.1 A
  • Power: 10 W
  • Single Output
  • Analog Display
Learn More
Agilent-6212A-Electrophoresis-Power-Supply-8173
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6420A Triple Quad LC/MS System

Agilent 6420A Triple Quad LC/MS System

Cambridge ID #: 17976

The Agilent 6420A Triple Quadrupole LC/MS System is equipped with performance specifications in Signal-to-Noise ratio and Instrument Detection Limit for routine analysis.

Specifications:

  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI positive: S/N > 6,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 2,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 60 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 60 fg
  • Mass range: m/z 5 – 2,250
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:1 Da from 5 – 1,000 m/z; 0.01% from 1,000 – 2,000 m/z; 0.02% from 2,000 – 2,250 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment, > 40,000 ion transitions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms

Features:

  • 1260 Infinity Binary Pump Clinical
  • 1260 Infinity high perfomance degasser clinical edition
  • 1260 Infinity high perfomrance autosampler clinical edition
  • PEAK Nitrogen generator system
Learn More
Agilent-6420A-Triple-Quad-LC-MS-System-17976
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6460C LC/MS System

Agilent 6460C LC/MS System

Cambridge ID #: 17703

The Agilent 6460C Triple Quadrupole LC/MS System is equipped with Agilent Jet Stream Technology to enable enhanced sensitivity. The 6460 provides a fast and robust solution to simultaneously quantify, screen, and confirm analytes in the laboratory.

  • Greater signal and reduced noise - Agilent Jet Stream technology uses super-heated nitrogen to improve ion generation and desolvation
  • Efficient analysis – fast MRM speeds allow for analysis of over 100 overlapping compounds in a given retention time window
  • Screen, confirm and quantify – Triggered MRM (tMRM) combines fast and sensitive MRM quantitation with the generation of a product ion spectrum for library searching and compound screening and confirmation
  • Fast polarity switching for analysis of both positive and negative ions

Specifications:

  • MRM sensitivity Signal-to-Noise ratio ESI positive: S/N > 30,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 10,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 12.5 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 12.5 fg
  • Mass range: m/z 5 – 3,000
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:
    • Da from 5 – 1,000 m/z
    • 01% from 1,000 – 2,000 m/z
    • 02% from 2,000 – 3,000 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment > 40,000 ion transactions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms
Learn More
Agilent-6460C-LC-MS-System-17703
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Cambridge ID #: 18290

Features:

  • Mass accuracy within 2 ppm gives you complete confidence in your analysis.
  • Powerful Agilent Jet Stream source enables you to uncover low level components.
  • Wide in-spectrum dynamic range facilitates simultaneous measurement of minor components in the presence of intense background interferences.
  • The latest developments in Agilent Infinity II UHPLC, 2D-LC, SFC, and even GC-APCI chromatographic interfaces give you blazing fast acquisition speed.
  • Powerful MassHunter software provides the latest software capabilities for profiling, characterizing, identifying, and quantifying compounds in complex mixtures via high-definition MS and MS/MS.
  • Check out the latest developments in untargeted screening and quantitation using Agilent’s All Ions MS/MS technique.

Specifications:

  • Sensitivity, MS mode, electrospray on-column, 400 µL/min flow rate: 200:1 RMS; Option 200: 60:1 RMS
  • Sensitivity, MS/MS mode, electrospray on-column, 400 µL/min flow rate: 500:1 RMS; Option 200: 180:1 RMS
  • Mass resolving power: Greater than 10,000 at 118 m/z; Greater than 20,000 FWHM at 1,522 m/z
  • Mass accuracy, MS mode, electrospray on-column, 400 µL/min: Better than 2 ppm RMS as measured from 10 repeat injections
  • Mass accuracy, MS/MS mode, electrospray on-column, 400 µL/min: Better than 3 ppm RMS on m/z 397 as measured from 10 repeat injections
  • Mass accuracy temperature stability, MS mode: Maintain 1 ppm mass accuracy (variations < 3 °C from calibration temperature)
  • Dynamic range: Up to 5 decades
  • Mass range: m/z 100 – 20,000 extended mass range m/z 50 – 1,700 or 50 – 3,200 for both high resolution and extended dynamic range modes Quadrupole up to 4,000 m/z
  • Spectral acquisition rate, MS mode: 50 spectra/second
  • Spectral acquisition rate, MS/MS mode mode: 50 MS/MS spectra/second
  • Positive to negative switching:5 seconds

Includes:

  • G5611A 1260 Quat Pump
  • G5667A 1260 HiP BioALS
  • G1316A 1260 TCC
  • G4212B 1260 DAD
  • G5664A 1260 BioFC-AS
  • Computer loaded with MassHunter BioConfirm (G829AA), Agilent SpectrumMill Proteomics (G2721AA), Mass Profiler Professional (G3835AA) and Personal METLIN metabolite database (G6825AA) software.
Learn More
Agilent-6530-QTOF-with-1260-Infinity-Bioinert-HPLC-LC-MS-System-18290
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6540A LC/ MS Q-ToF System

Agilent 6540A LC/ MS Q-ToF System

Cambridge ID #: 20099

Agilent 6540A UHD Accurate-Mass Q-ToF LC/MS with 1290 HPLC System

This unit is almost new from 2012. No samples were run except for the Agilent initial installation and routine annual PM.

Includes:

  • G6540A UHD Accurate Mass Q-TOF LC/MS. includes ultra-high definition Q-TOF, JetStream technology, MassHunter workstation. (Dual ESI for Jet Stream source)
  • G1947B LC/MS APCI Source. Includes APCI spray chamber, corona discharge needle, nebulizer, APCI vaporizer, and test calibration kit. Configuration for usage with Q-ToF
  • G4220A 1290 Infinity Binary Pump. Includes Intelligent System Emulation Technology (ISET), integrated degassing unit, solvent selection valve connecting capillaries, column, solvent cabinet, bottles, system tool-kit and CAN cable.
  • G4226A 1290 Infinity Autosampler. A 1200 bar autosampler module in Agilent's new 1290 Infinity series of LC system. It features less than 100 ul of hydraulic delay volume and low carryover with flow-through injection design.
  • G1316C 1290 Infinity Thermostatted Column Compartment For use with any 1290 Infinity or 1260 Infinity system requiring low dispersion or special valve solutions. Temperature up to 100 degree C.
  • G4232B 2pos/10 port Valve head 1200bar. Includes 1200 bar QuickChange valve head, Capillary Kit 0.12mmID, G1316C 2/10 vlv
  • G3835A Mass Profiler Professional (MPP) Software.
  • G1953A PEAK Nitrogen Generator System. N2 Generator-PEAK Model NM32LA nitrogen generator with air compressor.
Learn More
Agilent-6540A-LC--MS-Q-ToF-System-20099
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Gas ChromatographyImage Coming Soon

Agilent 6890 Gas Chromatography

Cambridge ID #: 15391

The Agilent/HP 6890 GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. EPC reduces re-calibration frequency and improves laboratory productivity. Designed to work seamlessly with the 6890N, the included 7683 Autosampler connects without a controller box or multiple power cords/outlets, and is packed with features including Agilent’s fast-injection technology.

 

Includes:

  • FID Detectors (Flame Ionization Detectors) Optional
  • 7683 Autosampler (100 Vial Capacity)
  • Computer Loaded with Chemstation Software
  • Manuals and Cables

 

Features:

  • Electronic Pressure Control on detector and injector
  • Ambient temperature +4 °C to 450 °C
  • Temperature set point resolution: 1 °C
  • Supports 6 oven ramps with 7 plateaus, Negative ramps are allowed
  • Overview: Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
  • Accomplish more with networking abilities
    • Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
    • Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
  • Increased Laboratory Efficiency: Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
  • Decreased Calibration Time: You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
  • High Sample Throughput: The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
  • Minimal Rework: The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

 

Specifications:

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
  • Height: 50 cm (19.7 in.)
  • Width: 58 cm (26.8 in.)
  • Depth: 54 cm (21.6 in.)
  • Average Weight: 49 kg (108 lb)
  • Networkable: Yes
  • Ambient Operating Temperature: 15 ËšC to 35 ËšC
  • Ambient Operating Humidity: 5-95 %
  • Storage Extremes: -40ËšC to 65Ëš
  • Line Voltage Requirements: ±5% of nominal
  • Dimensions: 28 x 31 x 16 cm
  • Operating temperature: 4ËšC above ambient to 450ËšC
  • Maximum run time: 120ËšC/min
Learn More
Agilent-6890-Gas-Chromatography-15391
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 7000C Triple Quad w/ 7890B GC/MS/MS System

Agilent 7000C Triple Quad w/ 7890B GC/MS/MS System

Cambridge ID #: 19882

The 7000C Triple Quadrupole GC/MS was designed to deliver the most accurate quantitative results and confident identification even in the most complex matrices. The 7000C GC/MS system’s 4fg OFN Instrument Detection Limit (IDL) is demonstrated upon installation verifying unmatched ALS, GC and MS performance. Coupled with the 7890B GC, the 7000C MS works in perfect harmony to enhance productivity, save resources and alert operators about pending maintenance. The MassHunter software’s new, enhanced MRM optimization tools and the Pesticides and Environmental Pollutants Database comprehensive information content provides simple yet flexible MS/MS method development.

System Includes:

  • Agilent 7000C Quadruple GC/ MS MS EI System
  • Agilent 7890B GC
  • Agilent 7693A Autoinjector
  • Agilent 7693 150 Vial Tray
  • Computer laoded with MassHunter Software
Learn More
Agilent-7000C-Triple-Quad-w--7890B-GC-MS-MS-System-19882
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 7820A Gas Chromatography

Agilent 7820A Gas Chromatography

Cambridge ID #: 15052

Includes

  • Computer Loaded w/ Software
  • Dual Purged Packed Inlets
  • Dual FID
  • Dual EPC

 

Features:

  • Full electronic pneumatics control (EPC) is available for all inlets and detectors, ensuring excellent reproducibility, as well as reliable accuracy and precision
  • Electronic Pneumatics Regulation (EPR) provides the simplicity of manual operation with high precision digital display of pressure/flow and superior ease-of-use as compared to traditional manual pneumatics systems.
  • Easy to learn and use software – choose among a wide selection of OpenLAB CDS software offerings.
  • The simplified GC front panel keys and display provide sequence information, instrument conditions, and run status, and minimize operating errors
  • Supports the 7693A Automated Liquid Sampler and Tray (not heater/mixer/bar code), 50-sample automatic liquid sampler and PAL3 Auto Sampler systems.
  • Optimized performance for everyday productivity and for all routine applications, including those that must comply with regulatory requirements
  • Choice of inlets: Split/Splitless Inlet for megabore and all capillary columns; packed for wide bore capillary and packed columns, Programmable Cool On Column inlet for direct injection onto columns.
  • Choice of detectors: Flame Ionization Detector (FID); Thermal Conductivity Detector (TCD); micro-Electron Capture Detector (micro-ECD); Nitrogen-phosphorus Detector (NPD); and single wavelength Flame Photometric Detector Plus (FPD+)
  • Complementary software keyboard and display allows the user to control the system when it connects with an integrator or 3rd-party software
Learn More
Agilent-7820A-Gas-Chromatography-15052
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 7890B Gas Chromatography

Agilent 7890B Gas Chromatography

Cambridge ID #: 17228

Features:

The 7890B Gas Chromatograph (GC) System is one of the world’s most widely used GC system. It features accurate temperature controls and precise injection systems, plus enhanced Electronic Pneumatic Control (EPC) modules for the best retention times.

Specifications:

 

  • Dimensions (H x W x L): (19.2 in. x 22.9 in. x 20.2 in.)
  • Maximum Temperature: 450℃
  • Ambient Temperatures: +4℃ to 450℃
  • Temperature Setpoint Resolution: 0.1℃
  • Maximum Achievable Temperature Ramp Rate: 120℃/min
  • Maximum Operating Temperatures for Auxiliary Zones: 400℃
  • Storage Extremes: -40℃ to 70℃
  • Frequency: 50/60 Hz
  • Inlets: 2
  • Detectors: 3
  • Detector Signals: 4
  • Valves: Supports up to 8 valves

 

Learn More
Agilent-7890B-Gas-Chromatography-17228
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 8453 HPLC UV/VIS Detector

Agilent 8453 HPLC UV/VIS Detector

Cambridge Scientific ID #'s: 20107, 17711

System Includes:

  • Agilent G1103A UV-Vis Spectrophotometer
  • G1115AA/BA Spectral B.04.xx 32 Bit Chemstation Software or C.01.xx OpenLab Software (your choice)
  • Computer With Windows 7 Pro or Windows XP Operating System
  • Cables and Accessories

Specifications:

  • Wavelength range: 190–1100 nm
  • Slit width: 1 nm
  • EP resolution test: > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm
  • Stray light:
    • < 0.03 % at 340 nm (NaNO2, ASTM)
    • < 0.05 % at 220 nm (NaI, ASTM)
    • < 1 % at 198 nm (KCl, EP)
  • Wavelength accuracy:
    • < ± 0.5 nm 0.5-second scan (NIST 2034)
    • < ± 0.2 nm at 486.0 and 656.1 nm
  • Wavelength reproducibility: < ± 0.02 nm ten consecutive scans (NIST 2034)
  • Photometric accuracy:
    • < ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)
    • < ± 0.01 A at 235, 257, 313, 350, 430 nm, (potassium dichromate, EP method)
  • Photometric noise: < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms
  • Photometric stability: < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp.
  • Baseline flatness: < 0.001 A 0.5-second blank, 0.5-second scan, rms
  • Typical scan time: 5 second full range
  • Shortest scan time: 1 second full range
  • Time until next scan: 1 second full range, 0.1-second scan, up to 150 consecutive scans
Learn More
Agilent-8453-HPLC-UV-VIS-Detector-20107
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

Cambridge ID #: 14059

Includes 1 year Service Contract, Installation, and a PM at 6 months

 

Includes:

  • AB Sciex API4000 Qtrap LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Rough Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Agilent-1100-HPLC-LC-MS-MS-Q-Trap-System-14059
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14794

Includes 1 year Service Contract, Installation, and a PM at 6 months

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-14794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping