We offer an assortment of used and refurbished Waterbaths, Circulators and Chillers ranging from Hea...
Specifications:
Description:
Refrigeration service pump is designed for removing air and moisture from industrial and commercial chillers. Pump includes a gas ballast valve that inhibits condensation reducing corrosion, an On/Off switch, 3-wire cord, and oil.
Specifications:
These accurate and reliable chambers are ideal for long-term high temperature and relative humidity (RH) testing. Designed to provide a wide range of environments, these units are suitable for both industrial and biotechnology specification testing, specifically continuous-duty projects. All models are equipped with a gentle horizontal air flow system, which ensures stable, top-to-bottom temperature and RH uniformity. Low temperature models 9005L and 9010L feature CFC-free refrigerant. Relative humidity range may vary depending on temperature set point. Digitally set, microprocessor temperature and humidity controllers allow precise setting with direct digital read-out in degrees and percentage RH. The over-temperature safety control prevents possible damage to samples or equipment. A vapor generator compresses moisture and injects it into the chamber to provide controlled humidification. Automatic water level control maintains liquid level in humidity reservoir. Pressure coupling allows for easy hook-up of in-line plumbing or a carboy of distilled water. All units feature interior drain.
Specifications:
Features:
Features:
Features:
The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications.
Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.
The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.
The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.
â—† Easy to use, complete software control
â—† Integrated safety precautions for user protection
â—† Flexible configuration for a wide array of industrial apps
â—† Time-saving high speed analysis
Specifications:
Spectrometer System
Model:Flame AA System-A3F, Graphite AA System-A3G,
Combined Flame and Graphite Furnace AA System-A3FG
Monochromator
Graphite Furnace Analysis
Features:
The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications.
Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.
The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.
The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.
â—† Easy to use, complete software control
â—† Integrated safety precautions for user protection
â—† Flexible configuration for a wide array of industrial apps
â—† Time-saving high speed analysis
Specifications:
Spectrometer System
Model:Flame AA System-A3F, Graphite AA System-A3G,
Combined Flame and Graphite Furnace AA System-A3FG
Monochromator
Graphite Furnace Analysis
Features:
The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications.
Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.
The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.
The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.
â—† Easy to use, complete software control
â—† Integrated safety precautions for user protection
â—† Flexible configuration for a wide array of industrial apps
â—† Time-saving high speed analysis
Specifications:
Spectrometer System
Model:Flame AA System-A3F, Graphite AA System-A3G,
Combined Flame and Graphite Furnace AA System-A3FG
Monochromator
Graphite Furnace Analysis
Features:
The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:
AA990F-Flame atomizer only.
AA990G-Graphite furnace atomizer only.
AA990FG-Combined with flame and graphite furnace atomizer switch aromatically.
Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.
â—† Easy-to-use automation software
â—† Integrated safety precautions for user protection
â—† Precision accuracy with integrated correction system
â—† Life cycle value, best choice for less than 8 elements of analysis
Specifications:
Wavelength range: 190-900 nm
Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation: Square wave pulse
Modulation frequency :
100 Hz self reversal (SR) background,
400 Hz Deuterium Arc (D2) background
Monochromator
Grating: 1800 grooves/mm diffraction grating
Blazed wavelength: 250 nm
Focus: 300 nm
Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
Scan mode: Automatic
Photometric type: Single beam
Wavelength accuracy: ±0.15 nm
Wavelength resolution: 0.2 nm±0.02 nm
Wavelength reproducibility: <0.05 nm
Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
Baseline stability: 0.005 A/30 min
Background correction:
Deuterium Arc (D2) 1.0 Abs,
Self Reversal (SR) 3.0 Abs
Flame Analysis
Flame type: Air/acetylene
Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs
Characteristic Concentration: Cu<0.02 μg/ml
Detection limit: Cu<0.004 μg/ml
Repeatability: Cu<0.7 %
Burner head: Titanium Alloy
Nebulizer:
High–efficiency glass,
acid proof available as an option
Pre-mix chamber: Corrosion resistant
Atomizer selection:
Manual (AA990F)
Automatic changeover (AA990FG)
Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection
Graphite Furnace Analysis
Graphite head: Transversally heated
Temperature range: Ambient-2650 ℃
Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
Feedback: Voltage and optical temperature control feedback
Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
Features:
The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:
AA990F-Flame atomizer only.
AA990G-Graphite furnace atomizer only.
AA990FG-Combined with flame and graphite furnace atomizer switch aromatically.
Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.
â—† Easy-to-use automation software
â—† Integrated safety precautions for user protection
â—† Precision accuracy with integrated correction system
â—† Life cycle value, best choice for less than 8 elements of analysis
Specifications:
Wavelength range: 190-900 nm
Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation: Square wave pulse
Modulation frequency :
100 Hz self reversal (SR) background,
400 Hz Deuterium Arc (D2) background
Monochromator
Grating: 1800 grooves/mm diffraction grating
Blazed wavelength: 250 nm
Focus: 300 nm
Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
Scan mode: Automatic
Photometric type: Single beam
Wavelength accuracy: ±0.15 nm
Wavelength resolution: 0.2 nm±0.02 nm
Wavelength reproducibility: <0.05 nm
Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
Baseline stability: 0.005 A/30 min
Background correction:
Deuterium Arc (D2) 1.0 Abs,
Self Reversal (SR) 3.0 Abs
Flame Analysis
Flame type: Air/acetylene
Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs
Characteristic Concentration: Cu<0.02 μg/ml
Detection limit: Cu<0.004 μg/ml
Repeatability: Cu<0.7 %
Burner head: Titanium Alloy
Nebulizer:
High–efficiency glass,
acid proof available as an option
Pre-mix chamber: Corrosion resistant
Atomizer selection:
Manual (AA990F)
Automatic changeover (AA990FG)
Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection
Graphite Furnace Analysis
Graphite head: Transversally heated
Temperature range: Ambient-2650 ℃
Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
Feedback: Voltage and optical temperature control feedback
Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
Features:
The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:
AA990F-Flame atomizer only.
AA990G-Graphite furnace atomizer only.
AA990FG-Combined with flame and graphite furnace atomizer switch aromatically.
Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.
â—† Easy-to-use automation software
â—† Integrated safety precautions for user protection
â—† Precision accuracy with integrated correction system
â—† Life cycle value, best choice for less than 8 elements of analysis
Specifications:
Wavelength range: 190-900 nm
Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation: Square wave pulse
Modulation frequency :
100 Hz self reversal (SR) background,
400 Hz Deuterium Arc (D2) background
Monochromator
Grating: 1800 grooves/mm diffraction grating
Blazed wavelength: 250 nm
Focus: 300 nm
Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
Scan mode: Automatic
Photometric type: Single beam
Wavelength accuracy: ±0.15 nm
Wavelength resolution: 0.2 nm±0.02 nm
Wavelength reproducibility: <0.05 nm
Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
Baseline stability: 0.005 A/30 min
Background correction:
Deuterium Arc (D2) 1.0 Abs,
Self Reversal (SR) 3.0 Abs
Flame Analysis
Flame type: Air/acetylene
Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs
Characteristic Concentration: Cu<0.02 μg/ml
Detection limit: Cu<0.004 μg/ml
Repeatability: Cu<0.7 %
Burner head: Titanium Alloy
Nebulizer:
High–efficiency glass,
acid proof available as an option
Pre-mix chamber: Corrosion resistant
Atomizer selection:
Manual (AA990F)
Automatic changeover (AA990FG)
Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection
Graphite Furnace Analysis
Graphite head: Transversally heated
Temperature range: Ambient-2650 ℃
Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
Feedback: Voltage and optical temperature control feedback
Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
Features:
The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:
AA990F-Flame atomizer only.
AA990G-Graphite furnace atomizer only.
AA990FG-Combined with flame and graphite furnace atomizer switch aromatically.
Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.
â—† Easy-to-use automation software
â—† Integrated safety precautions for user protection
â—† Precision accuracy with integrated correction system
â—† Life cycle value, best choice for less than 8 elements of analysis
Specifications:
Wavelength range: 190-900 nm
Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation: Square wave pulse
Modulation frequency :
100 Hz self reversal (SR) background,
400 Hz Deuterium Arc (D2) background
Monochromator
Grating: 1800 grooves/mm diffraction grating
Blazed wavelength: 250 nm
Focus: 300 nm
Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
Scan mode: Automatic
Photometric type: Single beam
Wavelength accuracy: ±0.15 nm
Wavelength resolution: 0.2 nm±0.02 nm
Wavelength reproducibility: <0.05 nm
Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
Baseline stability: 0.005 A/30 min
Background correction:
Deuterium Arc (D2) 1.0 Abs,
Self Reversal (SR) 3.0 Abs
Flame Analysis
Flame type: Air/acetylene
Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs
Characteristic Concentration: Cu<0.02 μg/ml
Detection limit: Cu<0.004 μg/ml
Repeatability: Cu<0.7 %
Burner head: Titanium Alloy
Nebulizer:
High–efficiency glass,
acid proof available as an option
Pre-mix chamber: Corrosion resistant
Atomizer selection:
Manual (AA990F)
Automatic changeover (AA990FG)
Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection
Graphite Furnace Analysis
Graphite head: Transversally heated
Temperature range: Ambient-2650 ℃
Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
Feedback: Voltage and optical temperature control feedback
Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
AirClean® Systems AC600 Series vertical laminar flow workstations are ideal for non-hazardous applications that require a clean work area. These compact, lightweight workstations provide positive-pressure, ISO 5 air throughout the chamber and sash opening, thus keeping airborne particulate away from sensitive applications. Given the small footprint and ease of installation (simply plug in the power cord), the AC600 Series vertical laminar flow workstations are an excellent choice for mobile ‘clean zones’ within your facility.
AirClean® Systems AC600 Series PCR Workstations combine ISO 5 HEPA-filtered air with UV light irradiation for the ultimate DNA/RNA manipulation and amplification work area. Cross-contamination during amplification of DNA and RNA can lead to results that are inaccurate, costing the lab technician valuable time and reagents. PCR Workstations minimize this risk by keeping airborne contaminants away from samples and irradiating work surfaces and tools between amplifications.
Features
Features an intuitive 3.75” display with touch-pad control with 4 languages: French, German, Spanish and English. Swivel 180 Rotating Controller and on-board connectivity to USB-A & B, Ethernet, RS-232/RS-485 and external temperature probe. Clearly displayed on-screen prompts and automatic performance optimization and specific heat tuning. Equipped with single-point calibration capability.
Specifications:
Features:
Features an intuitive 3.75” display with touch-pad control with 4 languages: French, German, Spanish and English. Swivel 180 Rotating Controller and on-board connectivity to USB-A & B, Ethernet, RS-232/RS-485 and external temperature probe. Clearly displayed on-screen prompts and automatic performance optimization and specific heat tuning. Equipped with single-point calibration capability.
Specifications: