We offer an assortment of refurbished and used Microscopes ranging from Inverted Microscopes, Compound Microscopes, Fluorescence Microscopes, Stereo/Dissecting Microscopes, and Biological Microscopes to Polarizing Microscopes. Some of our popular manufacturers include Nikon, Olympus, Zeiss, and Leica. We also feature microscope cameras, objectives and stands. Additionally, we sell a wide selection of Scanning Electron Microscopes including Hitachi and JEOL. Browse our used microscopes below.

Airclean Systems: 76-90 of 93

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Revco RCR051A15 Undercounter Refrigerator

Revco RCR051A15 Undercounter Refrigerator

Cambridge ID #: 16953

Features positive airflow systems, industrial-quality cabinet construction, and extra-strength refrigeration compressors, ideal for industrial, clinical, and scientific applications.

Specifications:

 

  • Temperature Range: 1 to 8°C
  • Capacity: 140 L
  • Dimensions: 20” x 20” (W x H)
  • Temperature Control: Digital
  • Number of Doors: 1
  • Number of Shelves: 2 Drawers
  • Display: LED
Learn More
Revco-RCR051A15-Undercounter-Refrigerator-16953
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Neslab RTE-211 Refrigerated Circulating WaterbathImage Coming Soon

Neslab RTE-211 Refrigerated Circulating Waterbath

Cambridge ID #: 10568

Description:

The NESLAB RTE 211 refrigerated bath chiller circulator offers powerful cooling and heating, expansive temperature ranges, and sophisticated controller technology. These robust, compact units offer precise temperature stability and high reliability for external circulation and in-bath applications. A versatile combination force and suction pump provides the pressure necessary to circulate fluid long distances to both open containers and closed loop systems.

Specifications:

  • Temperature Range: -25°C to + 150°C
  • Temperature Stability: ±0.01°C
  • Cooling Capacity: 500 Watts, 1705 BTU/Hour
  • Heater (watts): 800 (60 Hz)
  • Bath Work Area (L x W x D): 9.25 x 10 x 6 in. (23.5 x 25.4 x 15.2 cm)
  • Bath Volume: 3.2 gal (12.1 L)
  • Dimensions (H x W x D): 25 x 12.375 x 18.375 in. (63.5 x 31.4 x 46.7 cm)
  • Power Requirements: 115 V, 60 Hz
  • Weight: 99 lbs. (45 kg)
Learn More
Neslab-RTE-211-Refrigerated-Circulating-Waterbath-10568
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Neslab RTE-740 Refrigerated Circulating Waterbath

Thermo Neslab RTE-740 Refrigerated Circulating Waterbath

Cambridge ID #: 19907

The Thermo Scientific NESLAB™ RTE 740 RTE-740 refrigerated bath chiller circulator offers powerful cooling and heating, expansive temperature ranges, and sophisticated controller technology. These robust, compact units offer precise temperature stability and high reliability for external circulation and in-bath applications. An industrial-grade force and suction pump provides the pressure necessary to circulate fluid long distances to both open containers and closed loop systems.

Specifications: 

  • Temperature Range:-40°C to 200°C
  • Flow Rate:15 L/min
  • Capacity:7 L
  • Power Requirements:115V, 60Hz, 16A
Learn More
Thermo-Neslab-RTE-740-Refrigerated-Circulating-Waterbath-19907
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV12 *NEW* Vacuum Pump

Edwards RV12 *NEW* Vacuum Pump

Cambridge ID #: 17436

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.65 litres
  • Oil max: 1 litres
  • Displacement :
      50Hz: 14.2 m3h-1 / 8.4 ft3min-1
      60Hz: 17 m3h-1 / 10 ft3min-1
  • Speed (Pneurop 6602)
      50Hz: 12 m3h-1 / 7.1 ft3min-1
      60Hz: 14.2 m3h-1 / 8.4 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 32 mbar / 24 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 290 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

 

Learn More
Edwards-RV12-*NEW*-Vacuum-Pump-17436
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 Vacuum Pump

Edwards RV3 Vacuum Pump

Cambridge ID #: 22427

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-Vacuum-Pump-22427
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 *NEW* Vacuum Pump

Edwards RV3 *NEW* Vacuum Pump

Cambridge ID #: 17433

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-*NEW*-Vacuum-Pump-17433
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV5 *NEW* Vacuum Pump

Edwards RV5 *NEW* Vacuum Pump

Cambridge ID #: 17434

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement :
      50Hz: 5.8 m3h-1 / 3.4 ft3min-1
      60Hz: 7.0 m3h-1 / 4.1 ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 5.1 m3h-1 / 3.0 ft3min-1
      60Hz: 6.2 m3h-1 / 3.7 ft3min-1
  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 50 mbar / 38 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV5-*NEW*-Vacuum-Pump-17434
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV8 *NEW* Vacuum Pump

Edwards RV8 *NEW* Vacuum Pump

Cambridge ID #: 17435

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.45 litres
  • Oil capacity max: 0.75 litres
  • Displacement:
      50Hz: 9.7 m3h-1 / 5.7 ft3min-1
      60Hz: 11.7 m3h-1 / 6.9ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 8.5 m3h-1 / 5 ft3min-1
      60Hz: 10 m3h-1 / 5.9 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 38 mbar / 28.5 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV8-*NEW*-Vacuum-Pump-17435
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Savant RVT4104 Refrigerated Vapor Trap Speedvac

Savant RVT4104 Refrigerated Vapor Trap Speedvac

Cambridge ID #: 22420

Savant RVT4104 Refrigerated Vapor Trap from Thermo Scientific effectively condenses and traps a wide variety of solvent vapors that can contaminate and degrade vacuum pump oil. The RVT 4104 delivers an easy, safe and practical way to protect high vacuum, oil-sealed pumps in vacuum evaporation systems. The Savant RVT4104 ultra-low temperature refrigerated vapor trap, includes a built-in temperature gauge and vacuum pump interlock to protect the pump from accidental contamination. The RVT4104 has a 4L capacity; ultra low -104°C temperature traps high volatile solvents. 0.5" ID connecting hose is a consumable and also not included The Savant RVT system is great for labs using highly volatile solvents including hexane, chloroform, acetone, and methylene chloride.

 

Specifications:

  • Ultra Low Temperature Range: 0° to -104°C
  • Maximum Capacity: 4 Liters
  • Dimensions (W x D x H): 20" x 26" x 13" inches
  • Power: 120V | 60Hz
  • Weight: 138 lb
Learn More
Savant-RVT4104-Refrigerated-Vapor-Trap-Speedvac-22420
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
KNF Neuberger Laboport UN840.3 FTP Vacuum Pump

KNF Neuberger Laboport UN840.3 FTP Vacuum Pump

Cambridge ID #: 20634

Features:

The KNF LABOPORT N840.3FTP two-stage diaphragm vacuum pump is suitable for use with concentrators, rotary evaporators, and distillation equipment (sold separately). The pump has a 34 liters per minute (LPM) free air capacity with vacuum to 8 Torr and its polytetrafluoroethylene (PTFE) air flow path is corrosion resistant. The oil-free diaphragm pump allows operation without oil misting and contaminated oil disposal. The pump accepts 115V, 60 Hz input power.

KNF Neuberger, a division of KNF Group, manufactures diaphragm pumps and systems for gases, vapors, and liquids for laboratory and manufacturing applications. The company, founded in 1977, is headquartered in Trenton, NJ.

Specifications: 

  • Flow rate at atm. pressure: 20L/min

  • Ultimate vacuum: 8 mbar

  • Operating pressure: 14.5 psig

  • Connectors for tube: 3/8 in

  • Permissible media and ambient temperature: +5 … +40 °C

Learn More
KNF-Neuberger-Laboport-UN840.3-FTP-Vacuum-Pump-20634
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR VDI 25 HomogenizerImage Coming Soon

VWR VDI 25 Homogenizer

Cambridge ID #: 11014

Description:

Homogenizers are ideal for plant and animal homogenization, PCR applications, soil and wastewater extractions, and Karl Fischer titration. These high-speed rotor/stator homogenizers feature infinitely variable speed control and can be used to rapidly crush, tear, disintegrate, emulsify, or suspend particles in a liquid medium. The systems impart shear energy into a liquid emulsion or suspension far greater than that of a conventional mixer. The accessory dispersing elements provide a wide range of volumes and applications.

Learn More
VWR-VDI-25-Homogenizer-11014
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Savant VLP120 Vacuum PumpImage Coming Soon

Thermo Savant VLP120 Vacuum Pump

Cambridge ID #: 13306

Description:

Achieve maximum solute recovery with the Thermo Scientific™ Deep Vacuum Oil Pumps for Vacuum Concentrators, designed to work with all Thermo Scientific™ SpeedVac™ concentrating and freeze drying systems.

Specifications:

  • Oil Capacity: 0.7 L
  • Pump Displacement: 116 L/min. (at 60 Hz); 97 L/min. (at 50 Hz)
  • Ultimate Vacuum Level: 1.5 mtorr/1.95 x10³ mbar
  • Vacuum Inlet Fitting: 12.7 OD
  • Dimensions (D x W x H): 17 x 6 x 9” (420 x 160 x 230 mm)
  • Electrical Requirements: 115 V, 60 Hz
Learn More
Thermo-Savant-VLP120-Vacuum-Pump-13306
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Devices Vmax Kinetic Microplate Reader

Molecular Devices Vmax Kinetic Microplate Reader

Cambridge ID #: 20056

Specifications:

  • Wavelength Range: 400-750 nm
  • Photometric Range: 0.000 to 4.000 OD
  • Wavelength Selection: Filters
  • Photometric Resolution: 0.001 OD
  • Endpoint Read Time: 5 seconds
  • Minimum Kinetic Interval: 5 seconds
  • Temperature Range: Ambient
  • Plate Formats: 96 Well Plates
  • Optical Systems:  Filters

 

 

 

Learn More
Molecular-Devices-Vmax-Kinetic-Microplate-Reader-20056
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Excelitas X-Cite mini+ Microscope LED Fluorescence Light Source

Excelitas X-Cite mini+ Microscope LED Fluorescence Light Source

Cambridge ID #: 19640

 

Description:

The winning combination of output power and pricing makes X-Cite mini+ the ideal choice for routine imaging applications and HBO upgrade opportunities. X-Cite mini+ couples directly to the microscope, and while its output power surpasses even the X-Cite 120LEDBoost, it has a compact, air-cooled form factor of the X-Cite 120LEDmini.

 

Specifications:

  • Spectral range: 360 - 700nm - coverage from DAPI to Cy5, with the following advantages:
    • DAPI (UV LED) - Two models available - choose between 365nm and 385nm
      • XTMS (365nm) for a closer match to arc lamp output; compatible with narrow 365 DAPI filter sets
      • XTML (385nm) for use with sensitive specimens and 385 DAPI filter sets
      • UV OFF Mode - built into all systems; a few clicks of the speedDIAL disables the UV LED when not required, helping to preserve sensitive samples
    • TRITC/mCherry (500 - 600nm) - improved LED technology yields 60% more power in this critical wavelength range compared to X-Cite 120LEDmini
  • High output power - the performance of higher-end illuminators in a lower cost system
    • 3X higher output than competitive lower cost systems in TRITC, mCherry and Cy5
    • Matches or exceeds the 120LEDBoost performance across the visible spectrum
  • Quiet operation - similar to X-Cite 120LEDmini
  • Air-cooled with compact footprint - same as X-Cite 120LEDmini
  • Direct coupling to microscope - no change to optical layout, uses existing flanges    
  • Environmentally-friendly – Mercury-free and zero consumables
  • Long life-time - 20,000 hour (or 3 years) LED warranty
  • SpeedDIAL controller - intuitive fingertip control of shuttering and intensity level
  • Multiple control options - TTL / USB - compatibility with existing software drivers for easy, drop-in replacement
  • Foot pedal option - for hands-free manual operation
Learn More
Excelitas-X-Cite-mini+-Microscope-LED-Fluorescence-Light-Source-19640
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Excelitas X-Cite Mini+ *NEW* Microscope LED Fluorescence Light Source

Excelitas X-Cite Mini+ *NEW* Microscope LED Fluorescence Light Source

Cambridge ID #: 20596

 

Description:

The winning combination of output power and pricing makes X-Cite mini+ the ideal choice for routine imaging applications and HBO upgrade opportunities. X-Cite mini+ couples directly to the microscope, and while its output power surpasses even the X-Cite 120LEDBoost, it has a compact, air-cooled form factor of the X-Cite 120LEDmini.

 

Specifications:

  • Spectral range: 360 - 700nm - coverage from DAPI to Cy5, with the following advantages:
    • DAPI (UV LED) - Two models available - choose between 365nm and 385nm
      • XTMS (365nm) for a closer match to arc lamp output; compatible with narrow 365 DAPI filter sets
      • XTML (385nm) for use with sensitive specimens and 385 DAPI filter sets
      • UV OFF Mode - built into all systems; a few clicks of the speedDIAL disables the UV LED when not required, helping to preserve sensitive samples
    • TRITC/mCherry (500 - 600nm) - improved LED technology yields 60% more power in this critical wavelength range compared to X-Cite 120LEDmini
  • High output power - the performance of higher-end illuminators in a lower cost system
    • 3X higher output than competitive lower cost systems in TRITC, mCherry and Cy5
    • Matches or exceeds the 120LEDBoost performance across the visible spectrum
  • Quiet operation - similar to X-Cite 120LEDmini
  • Air-cooled with compact footprint - same as X-Cite 120LEDmini
  • Direct coupling to microscope - no change to optical layout, uses existing flanges    
  • Environmentally-friendly – Mercury-free and zero consumables
  • Long life-time - 20,000 hour (or 3 years) LED warranty
  • SpeedDIAL controller - intuitive fingertip control of shuttering and intensity level
  • Multiple control options - TTL / USB - compatibility with existing software drivers for easy, drop-in replacement
  • Foot pedal option - for hands-free manual operation
Learn More
Excelitas-X-Cite-Mini+-*NEW*-Microscope-LED-Fluorescence-Light-Source-20596
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping