Used Lab Equipment

Used Lab Equipment

Aliquoting Pipet Controller: 16-30 of 142

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1323A HPLC Communication Module

Agilent 1100 Series - G1323A HPLC Communication Module

Cambridge Scientific ID #'s: 6836, 16044, 9537

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323A-HPLC-Communication-Module-6836
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1323B HPLC Communication Module

Agilent 1100 Series - G1323B HPLC Communication Module

Cambridge Scientific ID #'s: 16043, 15085

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17971, 13182, 23203, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17971
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 22334, 22331, 21294

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications Controller: area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features:  Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:  
    • 1 – 100 μl in 0.1 μl increments
    • Up to 1500 μl with multiple draw (hardware modification required)
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 μl,
    • Typically < 1 % RSD from 1 – 5 μl
  • Sample viscosity range:  0.2 – 5 cp
  • Sample capacity:
    • 2 × well-plates (MTP) + 10 × 2 ml vials
    • 100x2ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically < 30 s using following standard conditions:
    • Default draw speed: 200 μl/min
    • Default eject speed: 200 μl/min
    • Injection volume: 5 μl
  • Carry-over Typically:
    • < 0.01 % using the following conditions:
    • Column: 125 x 4 mm Hypersil ODS, 5 μm
    • Mobile phase: Water/Acetonitrile = 80/20
    • Flow rate: 1 ml/min
    • Injection volume: 1 μl caffeine (1 mg/ml), 5 μl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port

 

Learn More
Agilent-1100-Series---G1367A-HPLC-Well-Plate-Autosampler-22334
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 15934, 16078, 16060, 16141, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-15934
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1130-2S Recirculating Waterbath

VWR 1130-2S Recirculating Waterbath

Cambridge ID #: 19071

Features:

 

Microprocessor controller with LED set-and-read at an attractive price makes this model an excellent overall value. The bright LED display is easy to read and continuously displays actual temperature. The set temperature is displayed at the touch of a button. The 2-speed pressure (simplex) pump is used for closed-loop applications

 

Specifications:

Capacity: 6 liters

  • Temperature Range: Ambient + 5°C to 150°C
  • 120V
  • 60Hz
  • Reservoir Capacity: 28 liters
  • Pressure Flow Rate: 2-speed (Simplex Pump), 7 or 15 liters/min.
  • Working Access,L x W x D 12-1/8 x 10-3/4 x 8 in. 30.8 x 26.4 x 20.3 cm



Learn More
VWR-1130-2S-Recirculating-Waterbath-19071
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Boekel 113002 Dry Bath Incubator

Boekel 113002 Dry Bath Incubator

Cambridge ID #: 18438

Boekel Digital Dry Bath Incubators are designed to be used with standard aluminum dry blocks (nominally 3” x 3¾” x 2” high) of varying configurations for heating test tubes, microtubes and other small vessels. These Incubators are available in two sizes; Model 113002 has a two block capacity and includes an easily programmed PID (proportional integrative derivative) controller for rapid heat-up and accurate temperature control.

 

Specification:

 

  • Dimensions (W x D x H): 8 x 9.8 x 3.5 in. (20.3 x 24.9 x 8.6 cm)
  • Net weight: 5 lbs. (2.3 kg)
  • Power: 115 VAC, 200 watts / 230 VAC, 230 watts
  • Temperature range: ambient 5°C to 120°C
  • Uniformity: ±0.25°C at 37°C
  • Stability: ±0.2°C from 37 - 100°C
Learn More
Boekel-113002-Dry-Bath-Incubator-18438
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1136 Heated / General Purpose WaterbathImage Coming Soon

VWR 1136 Heated / General Purpose Waterbath

Cambridge ID #: 14892

Specifications:

  • Digital Controller
  • 1000W heater
  • Temperature range ambient +5C up to 200C
  • 6L chamber capacity
Learn More
VWR-1136-Heated---General-Purpose-Waterbath-14892
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 1152049S Hot Plate/Stirring Hot Plate

Fisher Scientific 1152049S Hot Plate/Stirring Hot Plate

Cambridge ID #: 18374

Features:

This basic stirring hotplate is built with a ceramic top plate design which reduces chances of breakage and is resistant to acids and alkalis. It is also designed to divert spills away from the internal components for product and user safety.

Specifications:

  • Controller Type: Knob
  • Speed: 2500 rpm
  • Voltage: 120V
  • Material: Ceramic
  • Surface Area: 7 x 7 in.
  • Temperature Range (English): 1000°F
  • Temperature Range (Metric): 538°C
  • Hertz: 60Hz
  • Electrical Requirements: 120V 60Hz
Learn More
Fisher-Scientific-1152049S-Hot-Plate-Stirring-Hot-Plate-18374
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 1152049SH Hot Plate/Stirring Hot PlateImage Coming Soon

Fisher Scientific 1152049SH Hot Plate/Stirring Hot Plate

Cambridge ID #: 18639

Specifications:

  • Speed: 2500 rpm
  • Temperature Range: 538°C
  • Material: Ceramic
  • Surface Area: 7 x 7 in.
  • Electrical Requirements: 120V 60Hz
  • Controller Type: Knob
Learn More
Fisher-Scientific-1152049SH-Hot-Plate-Stirring-Hot-Plate-18639
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping