Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Incubators ranging from General purpose Incubators, C02 Incubators, C02 water-jacketed Incubators, Refrigerated Incubators, and Shaking Incubators to Environmental Incubators and Humidity Incubators. Some of our popular manufacturers include Fisher, VWR, Thermo Forma, Precision, Sanyo and Hereaus.

Aries Filter Works: 1-15 of 150

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Aries Filter Works Phoenix PHX-CT-S-1 Water Purification

Aries Filter Works Phoenix PHX-CT-S-1 Water Purification

Cambridge ID #: 16507

Description: The Phoenix Ultra High-purity Lab Water System from Aries FilterWorks delivers Type I, 18.2 Megohm water quality on demand. The water is purified using a staged purification process which includes high-purity ion exchange resins to remove dissolved minerals and internal recirculation to maintain purity. As the water exits the system, a final filter removes particulates and bacteria to reach Type I water specifications. Additional technologies are offered depending on the application, including UV and Ultrafiltration. Multiple sensors continuously monitor the system and final water quality to ensure trouble free operation.

 

Specifications:

 

  • Dimensions (H x W x D): 21.5 in. x 18.25 in. x 18.25 in.
  • Weight: 42 lbs. dry / 47 lbs. operating
  • Inlet Connection: 3/8" O.D. Tubing (9.53 mm O.D. Tubing)
  • Max Inlet Pressure Range: 20 to 90 psi
  • Max. Output Flow: 2.5Lpm
  • Inlet Water Temperature Range: 40 - 100 Degrees F
  • Power Requirements: 120 VAC/ 60 Hz @ 1.0 amp
  • Pressure: 90 PSIG Maximum/ 20 PSIG Minimum
  • Temperature (Max.): 100ËšF (30°C)
  • Flow Rate (Typical): 0.67 Gallons Per Minute (2.5 Liters Per Minute), < 2.0 LPM with Ultrafilter and Endotoxin filter installed
  • Dimensions (H x W x D): 21.6 in. x 14.7 in. x 14.4 in. (54.8cm x 37cm x 36.5cm)
  • Weight: 42 lbs. dry / 47 lbs. operating (22.7 kg dry / 25 kg operating)

 

 

Learn More
Aries-Filter-Works-Phoenix-PHX-CT-S-1-Water-Purification-16507
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Leica  DMI4000 B Inverted Phase Contrast Microscope

Leica DMI4000 B Inverted Phase Contrast Microscope

Cambridge ID #: 23693
  • The Leica DMI4000 B automated inverted research microscope is ideal for scanning cell and tissue cultures. The system features a fluorescence axis for ultra brilliant fluorescence imaging.
  • The internal filter wheel with motorized excitation manager and FIM (Fluorescence Intensity Manager) enables excitation of fluorochromes in less than 20 milliseconds.
  • FIM regulates light intensity at five fixed levels and remembers the setting for each filter cube.
  • For special diagnostics requirements, the microscope is certified for in-vitro-diagnostics (IVD) like in-vitro-fertilization (IVF).
  • Learn More
    Leica-DMI4000-B-Inverted-Phase-Contrast-Microscope-23693
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Qiagen  QIAgility PCR / Thermal Cyclers

    Qiagen QIAgility PCR / Thermal Cyclers

    Cambridge ID #: 20576

    Features:

    The QIAgility is a compact benchtop instrument that enables rapid, high-precision setup of PCR experiments with ready-to-use software for ease and convenience. The software provides step-by-step guidance for worktable setup and automatic calculation of all mixes, eliminating the need to program pipetting steps. Just select the kit and cycler, define your targets and start the run. For added flexibility the QIAgility is operated via a laptop computer.

     

    Specifications:

    • CommunicationsUSB and RS232

    • Conductive Filtered Tips50 µl and 200 µl Conductive Filtered Tips for liquid-level sensing

    • Consumables (supplied): 10 racks of 50 µl Conductive Filtered Tips (960); 10 racks of 200 µl Conductive Filtered Tips (960); 25 x 5 ml tubes; 100 x 0.2 µl PCR tubes; 3 Tip Disposal Boxes

    • Dimensions Height: 45 cm (18 in.), instrument lid closed; Height: 86 cm (34 in.), instrument lid open; Width: 54 cm (21 in.); Depth: 63 cm (25 in.), without cables

    • Electrical: 100–240 V AC, 250 VA, 50–60 Hz

    • HEPA filter: Preinstalled dual-cartridge 3M Air-Mate HEPA (High Efficiency Particulate Air) filter system provides positive pressure clean air within the closed hood.

    • Humidity: Operating humidity: 40–70%

    • Liquid-level sensing: Minimum detection volume (10 µl in 200 µl PCR tubes). Only functional in combination with QIAGEN Conductive Filtered Tips.

    • Notebook (supplied): QIAgility comes with a notebook computer for added flexibility.

    • Pipetting head: Single channel

    • Place of operation: For indoor use only

    • Pollution level: 2

    • Precision: CV <1%, 5–200 µl (dry-well transfer) CV <5%, 2–5 µl (wet-well transfer) CV <10%, 1 µl

    • Software: Supplied with unlimited user license. Free upgrades by Web download.

    • Table capacity: 6 x SBS positions (127.76 x 85.48 mm) for adapters and Tip Rack Holders 1 x Master Mix Block 1x Reagent Block

    • TemperatureOperating temperature, 15–30 °C (59–86°F)

    • Tip disposal: All used tips ejected externally — no waste accumulation on the worktable

    • Tip volume: 1–200 µl

    Learn More
    Qiagen-QIAgility-PCR---Thermal-Cyclers-20576
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Cambridge ID #: 11049

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Cambridge Scientific ID #'s: 23960, 17971, 13182, 23203, 16326, 21821

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-23960
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

    Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

    Cambridge ID #: 22633

    Specifications: 

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Noise: ± 0.75 x 10 -5 AU, at 254 nm
    • Drift: 3 x 10-4AU/hr, at 254 nm
    • Linearity: >2 AU upper limit
    • Wavelength range: 190-600 nm
    • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
    • Maximum data rate: 55 Hz
    Learn More
    Agilent-1200-Series---G1314B-HPLC-Variable-Wavelength-Detector-22633
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

    Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

    Cambridge ID #: 15899

    Specifications: 

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Noise: ± 0.75 x 10 -5 AU, at 254 nm
    • Drift: 3 x 10-4AU/hr, at 254 nm
    • Linearity: >2 AU upper limit
    • Wavelength range: 190-600 nm
    • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
    • Maximum data rate: 55 Hz
    Learn More
    Agilent-1200-Series---G1314C-HPLC-Variable-Wavelength-Detector-15899
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1315D HPLC Diode Array Detector

    Agilent 1200 Series - G1315D HPLC Diode Array Detector

    Cambridge ID #: 24076

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1315D-HPLC-Diode-Array-Detector-24076
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1316A HPLC Column Compartment

    Agilent 1200 Series - G1316A HPLC Column Compartment

    Cambridge Scientific ID #'s: 24074, 24128, 23962

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1316A-HPLC-Column-Compartment-24074
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 23961, 24073

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-23961
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1260 Series - G1315D HPLC Diode Array Detector

    Agilent 1260 Series - G1315D HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 20570, 24158

    Features:

    The detector is designed for highest optical performance, GLP compliance and easy maintenance. 

    Specifications:

    • Detection Type: 1024-element photodiode array
    • Light Source: Deuterium and tungsten lamps The UV-lamp is equipped with RFID tag that holds lamp typical information.
    • Data Rate: up to 80 Hz
    • Wavelength Range: 190 – 950 nm
    • Short Term: noise (ASTM) Single and Multi-Wavelength: < ± 0.7·10-5 AU at 254 and 750 nm
    • Drift: < 0.9·10-3 AU/h at 254 nm 
    • Linear Absorbance Range: > 2 AU (5 %) at 265 nm
    • Wavelength Accuracy: ± 1 nm ,Self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength Bunching: 1 – 400 nm, Programmable in steps of 1 nm
    • Slit Width: 1, 2, 4 , 8, 16 nm Programmable slit
    • Diode Width: < 1 nm
    Learn More
    Agilent-1260-Series---G1315D-HPLC-Diode-Array-Detector-20570
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Welch 1402 Vacuum Pump

    Welch 1402 Vacuum Pump

    Cambridge ID #: 11804

    DuoSeal Vacuum Pumps are known for their ruggedness world-wide. These rotary vane pumps have large oil reservoirs to dilute contaminants. Low pump rpm to reduces friction and wear while minimizing reservoir temperature to lessen chemical reactivity. Pump can be ordered with an optional exhaust filter to control oil mist.

    Specifications:

    • Free Air Displacement cfm (l/min.) @60Hz: 5.6(160)
    • Ultimate Pressure: 1 x 10-4(0.00013)
    • Pump RPM: 525
    • Oil Capacity: 2.25(2.1)
    • Motor Horsepower (watts): 1/2(370)
    • Overall Dimensions LxWxH in. (cm):  20x12x15 (51x30.5x60)
    Learn More
    Welch-1402-Vacuum-Pump-11804
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Welch 1402B-01 Duoseal Vacuum Pump

    Welch 1402B-01 Duoseal Vacuum Pump

    Cambridge ID #: 11271

    DuoSeal Vacuum Pumps are known for their ruggedness world-wide. These rotary vane pumps have large oil reservoirs to dilute contaminants. Low pump rpm to reduces friction and wear while minimizing reservoir temperature to lessen chemical reactivity. Pump can be ordered with an optional exhaust filter to control oil mist.

    Specifications:

    • Free Air Displacement cfm (l/min.) @60Hz: 5.6(160)
    • Ultimate Pressure: 1 x 10-4(0.00013)
    • Pump RPM: 525
    • Oil Capacity: 2.25(2.1)
    • Motor Horsepower (watts): 1/2(370)
    • Overall Dimensions LxWxH in. (cm):  20x12x15 (51x30.5x60)
    Learn More
    Welch-1402B-01-Duoseal-Vacuum-Pump-11271
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Forma 3140 CO2 Water Jacketed Incubator

    Thermo Forma 3140 CO2 Water Jacketed Incubator

    Cambridge Scientific ID #'s: 11942, 21398

    Specifications:             

    • Capacity: 6.5 cu. ft. (184L)
    • CO2 Concentration Range: 0 to 20%
    • O2 Range: 1 to 20%
    • Relative Humidity: Ambient to 95% at 37°C
    • Humidity System: 3L stainless-steel pan
    • Temperature Range: Ambient +5°C to 55°C
    • Temperature Uniformity: ±0.2°C at 37°C
    • Chamber: Polished stainless-steel interior with coved corners
    • Interior D x W x H: 0 x 21.3 x 26.8 in. (50.8 x 54.1 x 68.1cm)
    • Shelving: Stainless steel
    • Exterior L x W x H: 25 x 26.0 x 39.5 in. (63.5 x 66.0 x 110.3cm)
    • Port(s): Chamber thru-wall access port with filter; RS-485 interface (optional)
    • Net Weight: 265 lb. (120.2kg)
    • Shipping Weight: 324 lb. (147kg)
    Learn More
    Thermo-Forma-3140-CO2-Water-Jacketed-Incubator-11942
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Thermo Scientific 3140 CO2 Water Jacketed Incubator

    Thermo Scientific 3140 CO2 Water Jacketed Incubator

    Cambridge ID #: 23523

    Specifications:             

    • Capacity: 6.5 cu. ft. (184L)
    • CO2 Concentration Range: 0 to 20%
    • O2 Range: 1 to 20%
    • Relative Humidity: Ambient to 95% at 37°C
    • Humidity System: 3L stainless-steel pan
    • Temperature Range: Ambient +5°C to 55°C
    • Temperature Uniformity: ±0.2°C at 37°C
    • Chamber: Polished stainless-steel interior with coved corners
    • Interior D x W x H: 0 x 21.3 x 26.8 in. (50.8 x 54.1 x 68.1cm)
    • Shelving: Stainless steel
    • Exterior L x W x H: 25 x 26.0 x 39.5 in. (63.5 x 66.0 x 110.3cm)
    • Port(s): Chamber thru-wall access port with filter; RS-485 interface (optional)
    • Net Weight: 265 lb. (120.2kg)
    • Shipping Weight: 324 lb. (147kg)