Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Autosampler: 1-15 of 51

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Thermo Forma Accela Autosampler HPLC AutosamplerImage Coming Soon

Thermo Forma Accela Autosampler HPLC Autosampler

Cambridge ID #: 12670

Features:

  • Optimized for high-throughput applications and sub two micron column particles
  • Maximum reproducibility with isothermal injection and separation
  • Greater application flexibility with multiple sample formats
  • Superior robustness with a diamond coated high pressure valve Accela Photo Diode Array Detector
  • Highest detection sensitivity with proprietary LightPipe technology
  • Designed for U-HPLC separations with a 1cm path length, 2µL LightPipe flowcell
  • Maximum peak resolution with fiberoptic beam shaper
  • Easy maintenance with integrated wavelength validation

 

Specifications:

  • Sample capacity:
    • 200 vials in five removable trays
    • 288 samples in three 96-well microplates
    • 1152 samples in three 384-well microplates
  • Standard vial:8 mL volume
  • Injection precision: < 1.0% RSD at 5 μL and up
  • Partial loop injection volume:
    • 10 μL with standard 25 μL sample loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Fixed loop (full loop) injection volume:
    • 25 μL with standard loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Sample carryover:
    • < 0.1%
    • 6 mL flush volumes, user-specified for internal and external needle wash cycles
  • Minimum sample volume: 1 μL can be injected from 5 μL
  • Needle height control:
    • Programmable in 0.1 mm increments
    • Active vial bottom search selectable on/off
  • Column oven: Programmable in 1 °C increments from 5 to 95 °C
  • Tray temperature control:
    • Programmable in 1 °C increments from 0 to 60 °C
    • Typical vial temperature from 4 to 50 °C
  • Reagent vials: Four 16 mL vials can be specified for flush/wash or dilution functions
  • Remote inputs: Pump ready, inject hold
  • Remote outputs: Pump stop, autosampler ready, inject, gradient start, four timed events
  • Ambient environment:10 to 40 °C, 5 to 95% relative humidity, non-condensing
  • Power requirements: 100/120/220/240 Vac nominal; 50/60 Hz, 550 VA
Learn More
Thermo-Forma-Accela-Autosampler-HPLC-Autosampler-12670
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge Scientific ID #'s: 9625, 9227, 15384, 7876, 16066, 15175, 16118

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-9625
By clicking below we can further assist you with your inquiry. Inquire 7 In Stock Worldwide Shipping
Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 15535, 15536, 15502, 15503, 17476, 17331, 16037, 15998

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-15535
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16189, 14777, 15501, 15508, 16031, 15189, 15135, 15356, 15353, 17335, 16030, 15504, 15999, 15289

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-16189
By clicking below we can further assist you with your inquiry. Inquire 14 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 17699, 17974, 15223, 16338, 17972

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Cambridge ID #: 13766

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • – 8 µl in 0.01 µl increments with the small loop capillary
    • – 40 µl in 0.01 µl increments with the extended loop capillary
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 40 µl,
    • Typically < 1 % RSD from 1 – 5 µl
    • Typically < 3 % RSD from 0.2 – 1 µl
  • Sample viscosity range: 2 – 5 cp
  • Sample capacity:
    • 2× well-plates (MTP) + 10 × 2 ml vials
    • 100 x 2 ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically, < 30 s using following standard conditions:
    • Default draw speed: 4 µl/min
    • Default eject speed: 10 µl/min
    • Injection volume: 0.1 µl
  • Carry-over:
    • Typically < 0.05 % using the following conditions:
    • Column: 150 x 0.5 mm Hypersil ODS, 3 µm
    • Mobile phase: Water/Acetonitrile = 85/15
    • Column Flow rate: 13 µl/min
    • Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port
Learn More
Agilent-1100-Series---G1377A-HPLC-Well-Plate-Autosampler-13766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1389A HPLC Autosampler

Agilent 1100 Series - G1389A HPLC Autosampler

Cambridge Scientific ID #'s: 9301, 16033, 10407

Specifications:

  • Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
  • Settable injection volume
    • to 8 µl with small loop capillary
    • to 40 µl with extended loop capillary
  • Precision
    • Typically < 0.5 % RSD from 5 to 40 µl
    • Typically < 1 % RSD from 1 to 5 µl
    • Typically < 3 % RSD from 0.2 to 1 µl
  • Minimum sample volume: µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
  • Carryover
    • Typically < 0.1 % without automated needle wash
    • Typically < 0.05 % with external needle cleaning and 1 µl injection volume
  • Sample viscosity range: 2 - 5 cp
  • Recommended pH-range: - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
  • Material in contact with solvent: Stainless steel, sapphire, PTFE, PEEK, fused silica
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in aintenance areas, error detection and display
  • Housing: All material recyclable

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1389A-HPLC-Autosampler-9301
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16330, 16315, 15076

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-16330
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative AutosamplerImage Coming Soon

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 2707 Autosampler

Waters 2707 Autosampler

Cambridge Scientific ID #'s: 15059, 15060

The 2707 Autosampler is a versatile, compact sample management system that makes highly precise and reproducible injections of samples into your LC or LC/MS system. It is ideally suited for laboratories where reduced carryover, maximized repeatability, high accuracy, and application flexibility are of concern.

 

Features:

  • Compact design yet easily serviceable
  • High-resolution syringe control for high-precision injections
  • Interchangeable fixed-volume sample loops
  • Variable-volume partial-loop injection capability
  • Optional sample cooling for consistent results
  • Pressure-assisted sample aspiration injection capability
  • Use of plates or vials, alone or in combination, for varied sampling formats
  • Empower Software control

 

Specifications:

  • Audible noise level: <65 dBA
  • Working temperature: 10 to 40 °C (indoor use only)
  • Storage temperature: -25 to +60 °C
  • Humidity: 20% to 80% RH
  • Installation class: II
  • Pollution degree: 2
  • Altitude: Up to 2000 m
  • Power requirements: 95 to 240 VAC ±10%; 50 to 60 Hz; 200VA
  • Viscosity range: 1 to 5.0 cP
  • Back pressure (maximum): 5000 psi (345 bar)
  • Sample capacity: 2 microtiter plates according to SBS standards; 96-well high/low and 384-well low formats, 48-vial or 12-vial trays; any combination of plates is allowed
  • Vial/plate dimensions (includes cap): Maximum vial/plate height: 4.7 cm (1.9 in.) (includes septa or cap mat)
  • Loop volumes: 5, 10, 20, 100 (standard), and 500 μL; 10 mL loop (standard) for prep option
  • Dispenser syringe: 500 μL standard or 2500 μL μL (standard for prep option)
  • Vial detection: Missing vial/well plate detection by sensor
  • Headspace pressure: Built-in compressor, only used for vials with septa
  • Switching time injection valve: Electrically <100 msec
  • Wash solvent: Integrated wash solvent bottle
  • Wetted parts in flow path: SS316, PTFE, TEFZEL, PEEK, Glass
  • Injection cycle time: <60 s for one injection, ≤100 μL including 300 μL wash
Learn More
Waters-2707-Autosampler-15059
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
YSI 2710 Analyzer AutosamplerImage Coming Soon

YSI 2710 Analyzer Autosampler

Cambridge ID #: 7500

Configuration:

  • Holds Up to 24 Tubes/Vials for 2700 System
  • Sample Container Diameter: 10-16 mm
  • Sample Container Height: 20 to 100 mm
Learn More
YSI-2710-Analyzer-Autosampler-7500
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE A-900 FPLC Autosampler

Amersham Biosciences GE A-900 FPLC Autosampler

Cambridge ID #: 6705

Features:

  • Loop volume 5-1000µl
  • 96 vials 1.5 ml vial capacity
  • A-900 autosampler designed for use with AKTA
  • Syringes 100 - 1000 µl
  • Built-in compressor
Learn More
Amersham-Biosciences-GE-A-900-FPLC-Autosampler-6705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE A-905 FPLC Autosampler

Amersham Biosciences GE A-905 FPLC Autosampler

Cambridge Scientific ID #'s: 14178, 14177

Features:

  • A-905 is an automated sampling injector for use with AKTA systems
  • Sample capacity: 96-well and 384-well microplates
  • Maximum total plate height: 47 mm
  • Dispenser syringe: 250 - 1000 µL
  • Loop volume: 5 - 1000 µL
  • Built-in compressor
Learn More
Amersham-Biosciences-GE-A-905-FPLC-Autosampler-14178
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping