Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Carr: 1-15 of 52

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Sorvall FA Micro Microplate CarrierImage Coming Soon

Sorvall FA Micro Microplate Carrier

Cambridge ID #: 8826
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Sorvall-FA-Micro-Microplate-Carrier-8826
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Carr Powerfuge P6 Industrial Centrifuge

Carr Powerfuge P6 Industrial Centrifuge

Cambridge ID #: 5628

Features:

  • 13,266 rpm / 15,000 x G
  • Continuous flow two-phase separation of solids and liquids
  • Up to 60 liters/hour
  • Previously used in a cGMP Lab
  • Integrated Drive Interface Module and Control Panel
Learn More
Carr-Powerfuge-P6-Industrial-Centrifuge-5628
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sorvall RTH 750 Microplate CarrierImage Coming Soon

Sorvall RTH 750 Microplate Carrier

Cambridge ID #: 8831

Description:

The Sorvall RTH-750 Rotor with Buckets features a capacity of 4 x 750mL tubes and has a maximum speed of 4000rpm. Additionally, the RTH-750 is autoclavable at 121°C and is intended for use in a RT7 centrifuge.

Specifications:

  • Material: Aluminum
  • Tube dimensions: 98 x 135 mm
  • Capacity: 4 x 750 mL tubes
  • Max speed: 4000 rpm
  • Max g-force: 3313
Learn More
Sorvall-RTH-750-Microplate-Carrier-8831
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sorvall Surespin & buckets Microplate Carrier

Sorvall Surespin & buckets Microplate Carrier

Cambridge ID #: 8792

Suresping 630 Rotor w/ (6) 36ml inserts

  • Max Speed: 30,000RPM
  • Max RCF: 166,880RPM
Learn More
Sorvall-Surespin-&-buckets-Microplate-Carrier-8792
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 15535, 15536, 15502, 15503, 17476, 17331, 16037, 15998

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-15535
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 17697, 15934, 16078, 18444, 16060, 16141, 17474, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-17697
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G2258A HPLC Manometric ModuleImage Coming Soon

Agilent 1100 Series - G2258A HPLC Manometric Module

Cambridge ID #: 18568

The Agilent 1200 Series Dual Loop Autosampler is a fixed loop sampler with two different sample loops. As a consequence of this design the metering device, also referred to as syringe, is not a part of the solvent flow path from pump to HPLC column. An additional flush solvent bottle is used to rinse this part of the hydraulic path after each injection. In order to minimize carryover, the sampler is equipped with a needle wash function which dips the needle into a wash vial or the wash port. The wash port is fed by a peristaltic pump and can be operated with most common HPLC solvents.

 

Specification:

 

  • Weight: 14 kg (29.8 lbs)
  • Dimensions (H x W x D): 200 x 345 x 440 mm (8 x 13.5 x 17 in.)
  • Line voltage: 100 - 240 VAC, ±10 % (wide-ranging capability)
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 200 VA
  • Power consumption (active power): 180 W
  • Ambient operating temperature:  4 - 55 °C (41 - 131 °F)
  • Ambient non-operating temperature: -40 - 70 °C (-4 - 158 °F)
  • Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F) non condensing
  • Operating altitude: up to 2000 meters (6500 ft)
  • Non-operating temperature: top to 4600 meters (14950 ft)
  • Safety standards (IEC, CSA, UL): Installation category II, pollution degree 2
Learn More
Agilent-1100-Series---G2258A-HPLC-Manometric-Module-18568
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G4227A HPLC Flex Cube

Agilent 1290 Series - G4227A HPLC Flex Cube

Cambridge ID #: 14803

The Agilent 1290 Infinity Flexible Cube is an auxiliary module for the 1290 Infinity Autosampler with a built-in pump to facilitate enhanced flushing capabilities and to reduce carry-over. With access to three solvents, critical sections of flow path can be flushed at high flow rates. Automated back-flushing of the injection needle-seat achieves the absolute lowest sample carryover for LC and LC/MS applications. In addition, the Flexible Cube hosts up to two Agilent Quick-Change valves. For utmost flexibility, choose among Agilent’s broad portfolio of available valve heads suitable up to 1200 bar. The valves can be controlled independently for any demanding valve-switching application.

 

Specifications

  • Injection range                          
    • 1 - 20 μL
    • .1 - 40 μL
    • .1 - 100 μL
    • in 0.1 μL increments
  • Precision: Precision of G4226A sampler will not be influenced
  • Accuracy: Accuracy of G4226A sampler will not be influenced
  • Sampler pressure range: Up to 1200 bar
  • Pressure range of flush pump: Up to 50 bar
  • Flow rate of flush pump: Up to 4 mL/min
  • Number of solvents: Up to 3 solvents
  • Sample viscosity range: 0.2 – 5 cp
  • Carry over:  Typically <0.001% (10 ppm)
Learn More
Agilent-1290-Series---G4227A-HPLC-Flex-Cube-14803
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 2707 Autosampler

Waters 2707 Autosampler

Cambridge Scientific ID #'s: 15059, 15060

The 2707 Autosampler is a versatile, compact sample management system that makes highly precise and reproducible injections of samples into your LC or LC/MS system. It is ideally suited for laboratories where reduced carryover, maximized repeatability, high accuracy, and application flexibility are of concern.

 

Features:

  • Compact design yet easily serviceable
  • High-resolution syringe control for high-precision injections
  • Interchangeable fixed-volume sample loops
  • Variable-volume partial-loop injection capability
  • Optional sample cooling for consistent results
  • Pressure-assisted sample aspiration injection capability
  • Use of plates or vials, alone or in combination, for varied sampling formats
  • Empower Software control

 

Specifications:

  • Audible noise level: <65 dBA
  • Working temperature: 10 to 40 °C (indoor use only)
  • Storage temperature: -25 to +60 °C
  • Humidity: 20% to 80% RH
  • Installation class: II
  • Pollution degree: 2
  • Altitude: Up to 2000 m
  • Power requirements: 95 to 240 VAC ±10%; 50 to 60 Hz; 200VA
  • Viscosity range: 1 to 5.0 cP
  • Back pressure (maximum): 5000 psi (345 bar)
  • Sample capacity: 2 microtiter plates according to SBS standards; 96-well high/low and 384-well low formats, 48-vial or 12-vial trays; any combination of plates is allowed
  • Vial/plate dimensions (includes cap): Maximum vial/plate height: 4.7 cm (1.9 in.) (includes septa or cap mat)
  • Loop volumes: 5, 10, 20, 100 (standard), and 500 μL; 10 mL loop (standard) for prep option
  • Dispenser syringe: 500 μL standard or 2500 μL μL (standard for prep option)
  • Vial detection: Missing vial/well plate detection by sensor
  • Headspace pressure: Built-in compressor, only used for vials with septa
  • Switching time injection valve: Electrically <100 msec
  • Wash solvent: Integrated wash solvent bottle
  • Wetted parts in flow path: SS316, PTFE, TEFZEL, PEEK, Glass
  • Injection cycle time: <60 s for one injection, ≤100 μL including 300 μL wash
Learn More
Waters-2707-Autosampler-15059
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 6890 Gas ChromatographyImage Coming Soon

Agilent 6890 Gas Chromatography

Cambridge ID #: 15391

The Agilent/HP 6890 GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. EPC reduces re-calibration frequency and improves laboratory productivity. Designed to work seamlessly with the 6890N, the included 7683 Autosampler connects without a controller box or multiple power cords/outlets, and is packed with features including Agilent’s fast-injection technology.

 

Includes:

  • FID Detectors (Flame Ionization Detectors) Optional
  • 7683 Autosampler (100 Vial Capacity)
  • Computer Loaded with Chemstation Software
  • Manuals and Cables

 

Features:

  • Electronic Pressure Control on detector and injector
  • Ambient temperature +4 °C to 450 °C
  • Temperature set point resolution: 1 °C
  • Supports 6 oven ramps with 7 plateaus, Negative ramps are allowed
  • Overview: Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
  • Accomplish more with networking abilities
    • Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
    • Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
  • Increased Laboratory Efficiency: Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
  • Decreased Calibration Time: You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
  • High Sample Throughput: The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
  • Minimal Rework: The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

 

Specifications:

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
  • Height: 50 cm (19.7 in.)
  • Width: 58 cm (26.8 in.)
  • Depth: 54 cm (21.6 in.)
  • Average Weight: 49 kg (108 lb)
  • Networkable: Yes
  • Ambient Operating Temperature: 15 ËšC to 35 ËšC
  • Ambient Operating Humidity: 5-95 %
  • Storage Extremes: -40ËšC to 65Ëš
  • Line Voltage Requirements: ±5% of nominal
  • Dimensions: 28 x 31 x 16 cm
  • Operating temperature: 4ËšC above ambient to 450ËšC
  • Maximum run time: 120ËšC/min
Learn More
Agilent-6890-Gas-Chromatography-15391
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890N Gas Chromatography

Agilent 6890N Gas Chromatography

Cambridge Scientific ID #'s: 15694, 15691

The Agilent/HP 6890N GC features electronic pneumatic control of all gas pressures and flows. On-board sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. EPC reduces re-calibration frequency and improves laboratory productivity. Designed to work seamlessly with the 6890N, the included 7683 Autosampler connects without a controller box or multiple power cords/outlets, and is packed with features including Agilent’s fast-injection technology.

 

Includes:

  • FID Detectors (Flame Ionization Detectors) OPtional
  • 7683 Autosampler (100 Vial Capacity)
  • Computer Loaded with Chemstation Software
  • Manuals and Cables

 

Features:

  • Electronic Pressure Control on detector and injector
  • Ambient temperature +4 °C to 450 °C
  • Temperature set point resolution: 1 °C
  • Supports 6 oven ramps with 7 plateaus, Negative ramps are allowed
  • Overview: Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
  • Accomplish more with networking abilities
    • Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
    • Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
  • Increased Laboratory Efficiency: Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
  • Decreased Calibration Time: You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
  • High Sample Throughput: The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
  • Minimal Rework: The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

 

Specifications:

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
  • Height: 50 cm (19.7 in.)
  • Width: 58 cm (26.8 in.)
  • Depth: 54 cm (21.6 in.)
  • Average Weight: 49 kg (108 lb)
  • Networkable: Yes
  • Ambient Operating Temperature: 15 ËšC to 35 ËšC
  • Ambient Operating Humidity: 5-95 %
  • Storage Extremes: -40ËšC to 65Ëš
  • Line Voltage Requirements: ±5% of nominal
  • Dimensions: 28 x 31 x 16 cm
  • Operating temperature: 4ËšC above ambient to 450ËšC
  • Maximum run time: 120ËšC/min
Learn More
Agilent-6890N-Gas-Chromatography-15694
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Sorvall 75006445 Rotor

Sorvall 75006445 Rotor

Cambridge ID #: 17237

This rotor fits legend RT Plus, legend T, Heraeus Multifuge 3S Plus, Multifuge 3SR Plus
With 4 deepwell microplate carriers, part (2) 75006449K & (2) 75006449J
And 4  TaqMan Array Micro Fluidic Card Holders

Specifications:

  • Maximum speed: 4,600 RPM
  • Maximum capacity: 4 x 750ml.

 

 

Learn More
Sorvall-75006445-Rotor-17237
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sorvall Heraeus 75006445 Rotor

Sorvall Heraeus 75006445 Rotor

Cambridge ID #: 15470

This rotor fits legend RT Plus, legend T, Heraeus Multifuge 3S Plus, Multifuge 3SR Plus
With 4 deepwell microplate carriers, part (2) 75006449K & (2) 75006449J
And 4  TaqMan Array Micro Fluidic Card Holders

Specifications:

  • Maximum speed: 4,600 RPM
  • Maximum capacity: 4 x 750ml.

 

 

Learn More
Sorvall-Heraeus-75006445-Rotor-15470
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Sample manager UPLC Sample Manager

Waters Acquity Sample manager UPLC Sample Manager

Cambridge ID #: 15769

Specifications:

  • Number of sample plates: Total of two plates, expandable to up to 22 plates with optional Sample Organizer (see below):
    • 96 and 384 microtiter plates
    • 48 position 2.00-mL vial plates
    • 48 position 0.65-mL micro-centrifuge tube plates
    • 24 position 1.50-mL micro-centrifuge tube plates
  • Maximum sample capacity: 768 in two 384-well plates; expandable to up to 8,448 samples with optional Sample Organizer
  • Number of sample injections: 1 to 99 injections per sample
  • Injection volume range: 0.1 to 50.0 iJL, in 0.1 iJL increments, partial or full loop mode; 10ul loop is standard; 1, 2, 5, 20, and 50-uL loops also available
  • Sample delivery precision(full loop injection mode): < 0.3% RSO, full loop, standard lO-iJL loop (default wash/purge conditions), per Waters AQT/SystemsQT protocol
  • Sample delivery precision(PLNO injection mode): < 1% RSO within 20% to 75% of loop volume for 1, 2, 5, 10, 20, and 50-iJL loops, UV detection
  • Injector linearity: > 0.999 coefficient of deviation (from 20% to 75%, partial loop overfill mode (PLNO injection mode), per Waters' AQT/SystemsQT protocol
  • Sample temperature control:0 to 40.0 ·C, settable in 0.1 ·C increments (assumes an ambient temperature of 25.0 ·C). At an ambient temperature of 21.0 ·C or lower the sample manager will maintain the temperature of the sample compartment down to 4.0 ·C with a tolerance of -2.0/+6.0 ·C, when configured with the maximum number of vials and/or plates
  • Injection cycle time:
    • < 15 sec between multipe injections with "load ahead" enabled
    • 30 sec with single weak wash, lO-iJL loop, pressure assist mode
  • Sample probe: XYZZ based needle-in-needle design
  • Minimum sample required: 5 uL residual, using maximum recovery 2-mL vials (zero offset)
  • Wash solvents: Two degassed: strong solvent and weak wash solvent, programmable to suit application
  • Sample carryover: < 0.005% or < 2.000 nL, whichever is greater
  • Advanced operations: Loop off-line mode, load ahead
  • Unattended operation: Leak sensors, full diagnostic data control captured through console software
  • Primary wetted material: Titanium alloy, 316 stainless steel, fluoropolymer, fluoroelastomer, PPS alloy, PEEK alloy, PPS, PEEK, OLC coating, gold
Learn More
Waters-Acquity-Sample-manager-UPLC-Sample-Manager-15769
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping