Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Flow Cytometers and Cell Sorters. Some of our popular manufacturers include Beckman-Coulter, BD Biosciences (Becton-Dickinson) and Guava.

Cart: 1-15 of 20

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Chart Industries CRYOCART CartImage Coming Soon

Chart Industries CRYOCART Cart

Cambridge ID #: 19301

MVE CryoCarts are designed for the loading of biological samples into canes, boxes, racks or frames. When used as a portable workbench, the unit will provide a safe and controlled environment for your samples for up to eight hours with the lid open. MVE CryoCart is ideal for transporting large quantities of samples from one tank to another within the same facility.

 

Specification:

 

  • Overall Dimensions (L x W x H): 51.7 x 17.6 x 38.9 in
  • Lift Overall Height: 36.3 in
  • Interior Dimensions (L x W x H): 41 x 13.2 x 15.4 in
  • Platform Height: 6 in
  • Footprint: 17.6 x 51.7 in
  • Weight (empty): 241 lbs
  • Weight with LN2 added (top of platform): 356 lbs
  • Approximate Hold Time w/ lid on hours: 18
  • Number of Racks: 2
Learn More
Chart-Industries-CRYOCART-Cart-19301
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Qiagen  QIAgility PCR / Thermal Cyclers

Qiagen QIAgility PCR / Thermal Cyclers

Cambridge ID #: 20576

Features:

The QIAgility is a compact benchtop instrument that enables rapid, high-precision setup of PCR experiments with ready-to-use software for ease and convenience. The software provides step-by-step guidance for worktable setup and automatic calculation of all mixes, eliminating the need to program pipetting steps. Just select the kit and cycler, define your targets and start the run. For added flexibility the QIAgility is operated via a laptop computer.

 

Specifications:

  • CommunicationsUSB and RS232

  • Conductive Filtered Tips50 µl and 200 µl Conductive Filtered Tips for liquid-level sensing

  • Consumables (supplied): 10 racks of 50 µl Conductive Filtered Tips (960); 10 racks of 200 µl Conductive Filtered Tips (960); 25 x 5 ml tubes; 100 x 0.2 µl PCR tubes; 3 Tip Disposal Boxes

  • Dimensions Height: 45 cm (18 in.), instrument lid closed; Height: 86 cm (34 in.), instrument lid open; Width: 54 cm (21 in.); Depth: 63 cm (25 in.), without cables

  • Electrical: 100–240 V AC, 250 VA, 50–60 Hz

  • HEPA filter: Preinstalled dual-cartridge 3M Air-Mate HEPA (High Efficiency Particulate Air) filter system provides positive pressure clean air within the closed hood.

  • Humidity: Operating humidity: 40–70%

  • Liquid-level sensing: Minimum detection volume (10 µl in 200 µl PCR tubes). Only functional in combination with QIAGEN Conductive Filtered Tips.

  • Notebook (supplied): QIAgility comes with a notebook computer for added flexibility.

  • Pipetting head: Single channel

  • Place of operation: For indoor use only

  • Pollution level: 2

  • Precision: CV <1%, 5–200 µl (dry-well transfer) CV <5%, 2–5 µl (wet-well transfer) CV <10%, 1 µl

  • Software: Supplied with unlimited user license. Free upgrades by Web download.

  • Table capacity: 6 x SBS positions (127.76 x 85.48 mm) for adapters and Tip Rack Holders 1 x Master Mix Block 1x Reagent Block

  • TemperatureOperating temperature, 15–30 °C (59–86°F)

  • Tip disposal: All used tips ejected externally — no waste accumulation on the worktable

  • Tip volume: 1–200 µl

Learn More
Qiagen-QIAgility-PCR---Thermal-Cyclers-20576
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Series - G4212B HPLC Diode Array Detector

Agilent 1260 Series - G4212B HPLC Diode Array Detector

Cambridge ID #: 19936

The 1290 Infinity Diode Array Detector (DAD) features a completely new optical design based on the Agilent Max-Light cartridge cell with optofluidic waveguides. With typical detector noise levels of < ± 0.6 μAU/cm the revolutionary 6 cm flow cell gives up to 10 times higher sensitivity than the 1200 Series DAD and VWD.  Any compromising refractive index and thermal effects are almost completely eliminated,

resulting in significantly less baseline drift for more reliable and precise peak integration. For ultra high productivity the 1290 Infinity DAD offers multiple wavelength and full spectral detection at sampling rates up to 160 Hz.

 

Features:

  • Ultra sensitivity through revolutionary Agilent Max-Light cartridge cell with 60 mm
  • optical path length (typically noise: < ± 0.6 μAU/cm).
  • Universal Agilent Max-Light cartridge standard cell with 10 mm optical path length
  • provides high sensitivity (noise: < ± 3 μAU) and lowest peak dispersion for 2.1, 3
  • and 4.6 mm ID columns.
  • Programmable slit from 1 to 8 nm provides optimum incident light conditions for
  • rapid optimization of sensitivity, linearity and spectral resolution.
  • Multiple wavelength and full spectral detection at high sampling rate of 160 Hz,
  • keeping pace with fastest possible analysis speed.
  • More reliable and robust peak integration process due through less baseline drift.
  • Full spectral detection for compound identification by spectral libraries or verification
  • of the separation quality with peak purity analysis for ultra fast LC. Simultaneous
  • detection of up to 8 signals for increased sensitivity and selectivity.
  • Wide linear range (typically up to 2.5 AU) – for reliable, simultaneous quantification
  • of primary compounds, by-products and impurities.
  • Radio frequency identification (RFID) technology for flow cells and lamp provide
  • new levels of data security and traceability.
  • Electronic temperature control (ETC) provides maximum baseline stability and
  • practical sensitivity under fluctuating ambient temperature and humidity conditions.
  • Reference wavelength for elimination of background interference.
Learn More
Agilent-1260-Series---G4212B-HPLC-Diode-Array-Detector-19936
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 2200 TapeStation Genetic Analyzer

Agilent 2200 TapeStation Genetic Analyzer

Cambridge ID #: 20637

Features:
8-well PCR tube strips or 96-well sample plates are available depending on sample throughput, bringing added flexibility.
Needle cartridges enable fast and simple needle exchange to ensure proper maintenance of the 2200 TapeStation system.
TapeStation Test Tape is available for troubleshooting and running System Diagnostics tests. The Tapes are reusable and expire after two years.

Specifications:

  • Input voltage: 12 V DC
  • Power consumption: 40 W (VA)
  • Current: 3 A Interface: USB cable (PC comms.)
  • Instrument Housing: UL94/VO rated flame retardant cast polyurethane
  • Dimensions: 400x 310x 310 mm
  • Weight: 12.5 kg
  • Power supply
    • Input voltage: 100 – 240 V AC
    • Input frequency: 50 – 60 Hz
    • Phase: 1
    • Current: 0.45 – 1.1 A
Learn More
Agilent-2200-TapeStation-Genetic-Analyzer-20637
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Scienceware Bel-Art Products 420741116 DesiccatorImage Coming Soon

Scienceware Bel-Art Products 420741116 Desiccator

Cambridge ID #: 13369

Description:

  • A UV light blocking, dry environment with automatic electronic dehumidification
  • The attractive design and sturdy construction of the Secador line of desiccator cabinets assures easy and reliable storage of moisture and light sensitive products.
  • Patented electronic dehumidification system reduces humidity and circulates dry air automatically, freeing users from monitoring and changing desiccants
  • Durastar™ co-polyester construction blocks 99% of UV light and resists staining, crazing and chemical attack
  • Amber color models reduce visible light penetration by over 50% for storing light sensitive materials like reagents, analytical standards and investigational compounds
  • Large doors with easy-to-view dial hygrometer maximize access to interior space and have a patented seal design, tab latches and security loops for a padlock or tamper-evident seals
  • Perforated shelves facilitate circulation of dry air; Space for desiccant under bottom shelf
  • U.S. Patents: 6,772,534; 6,834,920; 7,114,266; 7,318,630 and D474,626

Specifications:

  • Temperature Range: 41° to 104°F (5° to 40°C)
  • Voltage: 120 V
  • Shelf Type: Vented adjustable shelves
  • Material: Copolyester
  • Color: Clear with Blue End Caps
  • Shelves: 3
  • Autoclavable: No
  • Dimensions (L x W x H): 16.3 x 13.4 x 20.4 in. (41.4 x 34.1x 51.8 cm)
  • For Use With (Application): Easy and reliable storage of moisture and light sensitive products, can be used with Scienceware™ desiccant cartridges, canisters or similar desiccant
Learn More
Scienceware-Bel-Art-Products-420741116-Desiccator-13369
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
FinePCR ALB6400 Heating/ Cooling Block

FinePCR ALB6400 Heating/ Cooling Block

Cambridge ID #: 17855

Description:

  • Cooling and heating in one unit
  • Digital microprocessor control [PID] for highest accuracy
  • Independent cooling and heating systems for years of trouble-free operation
  • Various of interchangeable insert blocks
  • Block combined with the close fit of the tubes for efficient heat transfer
  • Special thicker blocks guarantee excellent temperature stability
  • Flashing alarm lamp to warn over-temperature
  • Over-temperature cut-out
  • Over temperature safety thermostat

Specifications:

  • Temperature Range: 0°C ~ 120°C
  • Temperature Accuracy: ±0.2°C
  • Cooling Method: Peltier
  • Heating Method: Cartridge heater
  • Weight: 8 kg
  • Dimensions (W x D x H): 190 x 278 x 230 mm
  • Wattage: 300W
  • Power: AC100V-240V
  • Frequency: 50/60Hz
Learn More
FinePCR-ALB6400-Heating--Cooling-Block-17855
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Agilent 1100 HPLC LC/MS/MS Q Trap System

Cambridge ID #: 14059

Includes 1 year Service Contract, Installation, and a PM at 6 months

 

Includes:

  • AB Sciex API4000 Qtrap LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Rough Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Agilent-1100-HPLC-LC-MS-MS-Q-Trap-System-14059
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

Cambridge Scientific ID #'s: 13945, 20542

Includes 1 year Service Contract, Installation, and a PM at 6 months

Method Development and Training also Available

 

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Shimadzu-20AD-UPLC-LC-MS-MS-Q-Trap-System-13945
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14794

Includes 1 year Service Contract, Installation, and a PM at 6 months

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-14794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Shimadzu 20AC UPLC LC/MS/MS  System

AB Sciex API 4000 w/ Shimadzu 20AC UPLC LC/MS/MS System

Cambridge ID #: 18606

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with HESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Shimadzu Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%

Optional Shimadzu UFLC System Components:

  • SIL-20AC
  • LC-20AB
  • CTO-20AC
  • CBM-20A
  • DGU-20A5
Learn More
AB-Sciex-API-4000-w--Shimadzu-20AC-UPLC-LC-MS-MS--System-18606
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 15382

Innovative QJet ion guide technology dramatically improves sensitivity by capturing and focusing more ions generated by the efficient TURBO V ion source. And the TURBO V source virtually eliminates cross-contamination, even with high-concentration samples.  New innovations in sensitivity like QJet ion guide technology make it possible to reach the lowest limits of detection. Combining QJet ion guide technology with the proven TURBO V ion source and a powerful new generation of Analyst software results in a robust, high throughput platform ideal for all phases of pharmaceutical development.

 

Includes:

  • AB Sciex API5000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse-counting channel electron multiplier (CEM) detector
  • Dynamic Range: 1 cps to 4 x 10(6) cps (pulse counting)
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.01% over the entire mass range
  • Mass Range: 5 – 1250 m/z
  • Scan Types:  Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Learn More
AB-Sciex-API-5000-LC-MS-MS-Mass-Spectrometer-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-15382
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Barnstead D12651 Water Purification

Barnstead D12651 Water Purification

Cambridge ID #: 14218

These systems purify water for general laboratory use or as a feed source for ultrapure systems. The 12 and 24 L/hr models use a diaphragm pump for quiet, efficient operation; the 6 L/hr model must be connected to an in-house line pressure. The built-in membrane protection system extends the life of the membrane. It includes a special cartridge that softens the water, and an automatic flush that removes scale build-up on the membrane. The control panel operates and monitors the main functions.

Specifications:

 

  • Maximum Flow Rate: 12 L/hour
  • Inlet Port: â…œ OD compression
  • Maximum Inlet Water Temperature: 35°C (95°F)

 

  • Minimum Inlet Water Temperature: 1°C (34°C)
Learn More
Barnstead-D12651-Water-Purification-14218
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BD BioScience FacsAria IIu Cell Sorter

BD BioScience FacsAria IIu Cell Sorter

Cambridge Scientific ID #'s: 14996, 17981

Includes PM From BD and Guaranteed Installable under BD Service Contract

Upgraded to IIu and Added Violet laser in 2014

 

The new BD FACSAria II cell sorter improves ease of use, flexibility, and aseptic capability to make it the best choice for consistent results in sorting across a broad range of applications. The heart of this cell sorting revolution is the true fixed-alignment flow cell, gel-coupled to the collection optics. Fixed alignment minimizes startup time and improves reproducibility. Gel coupling to the objective lens improves collection efficiency and increases the sensitivity and resolution needed for multicolor applications.

 

The BD FACSAria II cell sorter advances cell sorting with multiple improvements. A new fluidics design improves aseptic setup and cleaning. New nozzle sizes enable a wide range of particles to be sorted. Software improvements dramatically cut the time spent on cytometer setup, adjustment, and maintenance.

 

The BD FACSAria II cell sorter also sets a new standard for ease of use to improve both workflow and productivity. A new nozzle design allows for reproducible insertions. A new universal sort tube collection mount makes it easier to insert and remove tube holders. Software wizards and automation simplify aseptic sort setup, drop-delay determination, and clog detection. Compatibility with BD digital analyzers makes it easier to move from analysis to cell sorting.

 

Includes:

  • 3 lasers
  • Blue 7PMTs, Red 3PMTs, Violet 3 PMTs
  • Computer w/ FACSDiva 8 Software
  • ACDU
  • 2 monitors
  • Fluidics Cart
  • Temperature Control
  • Lauda Chiller

 

Performance

Fluorescence Sensitivity

  • Measurements performed at 70 psi and 90 kHz using SPHERO Rainbow Calibration Particles (RCP-30-5A)
  • FITC: 125 molecules of equivalent soluble fluorochrome (MESF-FITC)
  • PE: 125 molecules of equivalent soluble fluorochrome (MESF-PE)

Fluorescence Resolution

  • Coefficient of variation (CV)
  • PI: Area, <3.0%, full G0/G1 peak for propidium iodide (PI)-stained chicken erythrocyte nuclei (CEN)
  • Hoechst: Area, <3.5%, full G0/G1 peak for Hoechst-stained CEN

Fluorescence Linearity

  • Doublet/singlet ratio:
  • CEN stained with PI: 1.95–2.05 (off the 488-nm laser) or Hoechst: 1.95–2.05 (off the 405-nm laser)

Forward and Side Scatter Sensitivity

  • Sensitivity enables separation of fixed platelets from noise, identification of bacteria, and detection of 0.5-micron beads.

Forward and Side Scatter Resolution

  • Scatter performance is optimized for resolving lymphocytes, monocytes, and granulocytes.

Sample Acquisition Rate

  • Maximum acquisition rate (events per second) with 12 compensation pairs and 8 parameters: 70,000.
Learn More
BD-BioScience-FacsAria-IIu-Cell-Sorter-14996
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Becton Dickinson FacsAria IIu  - 4 Lasers Cell Sorter

Becton Dickinson FacsAria IIu - 4 Lasers Cell Sorter

Cambridge ID #: 19571

Includes PM From BD and Guaranteed Installable under BD Service Contract

 

New Flow Cell installed in September 2018

Also included are the excitation laser lines, laser powers and optical configuration.

 

The new BD FACSAria IIu cell sorter improves ease of use, flexibility, and aseptic capability to make it the best choice for consistent results in sorting across a broad range of applications. The heart of this cell sorting revolution is the true fixed-alignment flow cell, gel-coupled to the collection optics. Fixed alignment minimizes startup time and improves reproducibility. Gel coupling to the objective lens improves collection efficiency and increases the sensitivity and resolution needed for multicolor applications.

 

The BD FACSAria IIu cell sorter advances cell sorting with multiple improvements. A new fluidics design improves aseptic setup and cleaning. New nozzle sizes enable a wide range of particles to be sorted. Software improvements dramatically cut the time spent on cytometer setup, adjustment, and maintenance.

 

The BD FACSAria IIu cell sorter also sets a new standard for ease of use to improve both workflow and productivity. A new nozzle design allows for reproducible insertions. A new universal sort tube collection mount makes it easier to insert and remove tube holders. Software wizards and automation simplify aseptic sort setup, drop-delay determination, and clog detection. Compatibility with BD digital analyzers makes it easier to move from analysis to cellsorting.

 

Includes:

  • 4 lasers (375nm, 488nm, 405nm, 633nm)
  • Blue 7PMTs, Red 3PMTs, Violet 3PMTs
  • HP Computer w/ FACSDiva 8.0 Software
  • ACDU
  • 1 HP monitor
  • Fluidics Cart
  • Temperature Control
  • Lauda Chiller
  • Buffalo Whisper Aerosol Control
  • Under BD service contract since installed in 2012

 

Performance

Fluorescence Sensitivity

  • Measurements performed at 70 psi and 90 kHz using SPHERO Rainbow Calibration Particles (RCP-30-5A)
  • FITC: 125 molecules of equivalent soluble fluorochrome (MESF-FITC)
  • PE: 125 molecules of equivalent soluble fluorochrome (MESF-PE)

Fluorescence Resolution

  • Coefficient of variation (CV)
  • PI: Area, <3.0%, full G0/G1 peak for propidium iodide (PI)-stained chicken erythrocyte nuclei (CEN)
  • Hoechst: Area, <3.5%, full G0/G1 peak for Hoechst-stained CEN

Fluorescence Linearity

  • Doublet/singlet ratio:
  • CEN stained with PI: 1.95–2.05 (off the 488-nm laser) or Hoechst: 1.95–2.05 (off the 405-nm laser)

Forward and Side Scatter Sensitivity

  • Sensitivity enables separation of fixed platelets from noise, identification of bacteria, and detection of 0.5-micron beads.

Forward and Side Scatter Resolution

  • Scatter performance is optimized for resolving lymphocytes, monocytes, and granulocytes.

Sample Acquisition Rate

  • Maximum acquisition rate (events per second) with 12 compensation pairs and 8 parameters: 70,000.
Learn More
Becton-Dickinson-FacsAria-IIu----4-Lasers-Cell-Sorter-19571
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BD BioScience FacsCanto II - 3 Laser Flow Cytometer

BD BioScience FacsCanto II - 3 Laser Flow Cytometer

Cambridge ID #: 12160

The BD FACSCanto system breaks new frontiers in flow cytometry by providing an efficient, easy-to-use yet powerful six-color benchtop analyzer. It incorporates many technology advances first developed in the BD LSR II expandable analyzer and the BD FACSAria cell sorter. It supports a broad range of research applications, being particularly suited for rare event analysis with its high speed, great sensitivity, and minimal sample-to-sample carryover.

 

The BD FACSCanto system combines a patented optical design for enhanced signal retention on six fluorescent and two scatter parameters, digital electronics for processing up to 10,000 events per second, and a novel sample injection tube supporting carryover of less than 0.1%. Your total benefit consists of the best fluorescence sensitivity to resolve dim events, cleaner data due to minimal sample contamination, and rapid processing rates, preserving valuable time for science. BD FACSCanto performance overcomes obstacles in rare event analysis and in functional studies for low detection ranges.

 

Includes:

  • Computer w/ FacsDiva Software
  • Fluids Cart
  • 2 laser, Blue(488) and Red (633)
  • Laser
  • 6 PMTs unit and side scatter
  • All Necessary Cables
  • Manuals

 

Optics Specifications:

  • Lasers
    • Air-cooled:
    • 488-nm solid state, 20-mW laser output
    • 633-nm HeNe, 17-mW laser output
  • Laser Configuration: Spatially separated beams with 9 x 65-μm elliptical spots
  • Optical Alignment Procedure: Fixed, no operator alignment required
  • Flow Cell: 180 x 430-μm rectangular quartz flow cell
  • Collection Optics: Optical-gel coupled 1.2 NA lens
  • FSC Resolution: 0 μm
  • SSC Resolution: 5 μm
  • Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT
  • FSC Detector: Photodiode with 488/10 BP
  • SSC Detector: PMT with 488/10 BP
  • Fluorescence Detectors: 6 PMTs in 4-2 standard configuration
  • Blue Laser Dyes
    • FITC, PE, PerCP or PerCP-Cy™5.5,
    • PE-Cy7 (525, 575, 678 or 695, 785 nm)
  • Red Laser Dyes: APC, APC-Cy7 (660, 785 nm)
  • Detector Bands
    • Blue Laser: 530/30; 585/42; >670; 780/60 nm
    • Red Laser: 660/20; 780/60 nm
  • Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF
Learn More
BD-BioScience-FacsCanto-II---3-Laser-Flow-Cytometer-12160
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping