Used Lab Equipment

Used Lab Equipment

Ccd Microscope Monochrome Camera: 166-180 of 182

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Fluid Imaging Technologies FlowCam Nano *NEW* Sub-Micron Particle Analyzer

Fluid Imaging Technologies FlowCam Nano *NEW* Sub-Micron Particle Analyzer

Cambridge ID #: 18766

Description:

Introducing the FlowCam Nano® by Fluid Imaging Technologies. This patented oil immersion, flow imaging technology complements our industry-leading imaging particle analysis system to provide you with the most comprehensive particle analysis research and development tool for parenteral drug analysis.

Specifications:

  • Method: Oil immersion flow microscopy
  • Size Range: 300 nm to 30 μm
  • Minimum Sample Volume: 20 μl
  • Magnification & Flow Cell: 40X magnification with 50 μm flowcell
  • Numerical Aperture (NA): 1.4 NA
  • Camera’s Field of View: 150 μm height x 200 μm wide
  • Camera Frame Rate: Up to 120 frames per second
  • Focus Method: Manual
  • Flow Rate: 0.02 mL/minute
  • Image Format/Type: TIFF/ 8-bit Grayscale
Learn More
Fluid-Imaging-Technologies-FlowCam-Nano-*NEW*-Sub-Micron-Particle-Analyzer-18766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Alpha Innotech Fluorchem 5500 Gel Imaging System

Alpha Innotech Fluorchem 5500 Gel Imaging System

Cambridge ID #: 16297

Using advanced electrically cooled SuperChemiNova CCD camera technology, the FluorChem provides real time display and the R.S.D.P. standard of resolution, sensitivity, dynamic range and performance. The FluorChem is ideal for chemiluminescence, fluorescence, and visible imaging applications.

 

Features:

  • Applications: chemiluminescence, fluorescence and colorimetric
  • Transillumination White: For protein gels,autorads,film, plates and flasks
  • Transillumination UV: For the fluorescent gels such as EtBr, SYPRO Red, etc
  • Software: easy-to-use software for darkroom control, image capture, enhancement and analysis
  • Camera: High-performance, high resolution, CCD camera allows imaging of low-light samples in UV-illuminated, and fluorescent applications. 12.5x75mm, F1.2 Motorized Zoom Lens for ChemiImager 5500 with DE 500/400 cabinet (Includes motorized lens, ChemiImager 5500 camera mount, and cables. Requires AlphaEaseFC software version with software controls of motorized lens) -
  • Lens: Zoom lens, close-up 2+ diopter lens and interference filter
  • Filters: chemiluminescence samples, ethidium bromide, SYPRO Orange (595 nm) each filter has a bandwith +/-40 nm
  • Allows to visualize chemiluminscent reactions

 

How is this unit better than Alpha Imager 3400:

 

For low-light applications, such as chemiluminescence, a longer exposure time may be appropriate and it is best to go to the red ACQUIRE IMAGE button to directly acquire the image once the desired exposure time is set. Alternatively, if a good exposure time is unknown, try selecting Auto-Expose and using the super sensitivity selection. Auto-Expose will generate an image showing the signal intensity usually in less than 3 minutes. Afterwards, a different sensitivity (binning) mode can be selected to generate a better resolution image and the software will automatically calculate the new exposure time for you.

 

Learn More
Alpha-Innotech-Fluorchem-5500-Gel-Imaging-System-16297
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Alpha Innotech FluorChem HD2 Gel Imaging System

Alpha Innotech FluorChem HD2 Gel Imaging System

Cambridge Scientific ID #'s: 9347, 15573

Includes Computer Loaded with Software

 

The FluorChem HD2 System provides a complete array of image acquisition modes for common fluorescent and chemiluminescent applications.  The FluorChem HD2 System delivers higher sensitivity and a broader dynamic range than film can provide at similar exposure times. Captured images are saved digitally, making them easy to import into presentations and reports

 

Features:

 

  • Applications Types: Chemiluminescent, Colorimetric, uv, Fluorescent
  • Camera Resolution: 19 megapixels (2048 x 2048)
  • a/D: 16-bit
  • Recommended lens: 50 mm, f/0.95 Fixed, manual or motorized
  • Pixels: 4 x 7.4 μm
  • Filter Positions: 5, motorized
  • Size: 20" W x 15" D x 39.5" h (51 x 38 x 100 cm)
  • Weight: 100 lbs (45.4 kg)
Learn More
Alpha-Innotech-FluorChem-HD2-Gel-Imaging-System-9347
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Axon GenePix 4000B (02215450) MicroArray Scanner

Axon GenePix 4000B (02215450) MicroArray Scanner

Cambridge ID #: 19376

Includes:

  • Computer w/ GenePix Pro -  MicroArray Acquisition & Analysis Software
  • Flat Panel Monitor
  • All Necessary Cords, Cables
  • Manual

 

Features:

  • Speed. Unlike most commercially available microarray scanners, the GenePix 4000B Microarray Scanner acquires data at two wavelengths simultaneously. This means drastically reduced scan times and hence greater workflow efficiency. Apart from superior speed, simultaneous scanning eliminates potential errors associated with aligning two separately scanned images, and provides real-time access to data as they are acquired.
  • Add Reliability to Your Research. The performance calibration standards that come with your GenePix 4000B Microarray Scanner allow you to check the performance when you receive your scanner and at any time in the future. GenePix Pro Acquisition and Analysis Software includes one-touch calibration to restore any GenePix scanner to benchmark performance. You can rest assured knowing the signals you generate today are the same as a couple of years ago and in the future.
  • Automate Your Workflow. With automated photomultiplier (PMT) balancing. The fully integrated GenePix Pro Acquisition and Analysis Software, controls the GenePix 4000B Microarray Scanner and can automatically evaluate the required PMT gain values, for fast and easy optimization of signal intensity and channel balance. The GenePix 4000B Microarray Scanner then acquires data at your selected resolution between 5-100 micron, allowing the adjustment of image resolution and file size for each experiment.
  • Get More Published. For over 10 years and close to 6000 literature references, the GenePix 4000B Microarray Scanner has expanded the overall sample compatibility, with user-adjustable focus offset and laser power settings. This allows proper imaging of slides with either a raised surface, as with membrane-coated glass, or a recessed surface, as in embedded arrays.

 

Performance Specifications

  • Sample type: Standard microscope slide (1" x 3", 25 x 75 mm or 26 x 76 mm)
  • Scan area: Adjustable, 22 x 71.5 mm max.
  • Excitation: 532 nm and 635 nm solid-state lasers
  • Laser power settings: User-selectable 100%, 33% or 10% laser power
  • Emission filters: Two, optimized for Cy3 and Cy5 or spectrally similar dyes
  • Detection: Dual photomultipliers (PMTs), automatic and manual gain adjustment
  • Focus offset: Adjustable between -50 and +200 μm (5 μm increments)
  • Optics: Non-confocal
  • Scanning method: Simultaneous, 2-channel
  • Scan time:5 minutes for both channels, 10 μm resolution, full scan area
  • Pixel resolution: Adjustable from 5-100 μm
  • Digital resolution: 16-bit
  • Dynamic range: Four orders of magnitude at SNR > 3
  • Image type: Single- or multi-image TIFF
  • Barcode reading: Image-based software barcode reader

 

General Specifications

  • Dimensions (in.):5 (W) x 8.0 (H) x 17.5 (D)
  • Dimensions (cm): 34 (W) x 20 (H) x 44 (D)
  • Weight: 45 lbs. (20 kg)
  • Power supply: 110/220V universal
  • Genomics: Directed at the genome sequence itself, microarrays have been used to identify novel genes, binding sites of transcription factors, changes in DNA copy number, and variations from a baseline sequence, such as in emerging strains of pathogens or complex mutations in disease-causing human genes.
Learn More
Axon-GenePix-4000B-(02215450)-MicroArray-Scanner-19376
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare ImageQuant LAS 4000 Variable Mode Imager System

GE Healthcare ImageQuant LAS 4000 Variable Mode Imager System

Cambridge ID #: 20816

Features:

The ImageQuant LAS 4000 is a camera system for producing digital images of gel or membrane samples or films. It is used together with the ImageQuant LAS 4000 Control Software to:

• Expose chemiluminescent samples or membranes.

• Expose fluorescent samples using epi (incident) or trans (transmitted) light sources, for example gels stained by ethidium bromide (EtBr). The ImageQuant LAS 4000 can be supplied with NIR, Red, Green, Blue and UV epi lights.

• Expose dye-stained gels and membranes or films using epi or trans illumination.

• Expose a sample repeatedly, incrementally or by programming exposure schemes.


Specifications:

  • CCD: 3 200 000 pixels (Fujifilm super CCD
  • Cooling temperature: -25°C
  • Exposure time: 1/100 seconds to 2 hours (Images can be continuously exposed for up to 30 hours using ImageQuant LAS 4000 Control Software.)
  • Lens: High-sensitivity lens F0.85 43 mm, Wide view lens F1.8 24 mm
  • Number of gradations:

Recorded image: 16 bit

Focusing: 8 bit

 

Learn More
GE-Healthcare-ImageQuant-LAS-4000-Variable-Mode-Imager-System-20816
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 NanoDrop 8000

NanoDrop 8000

Cambridge ID #: 21640

Description:

Thermo Scientific™ NanoDrop 8000 is a muti-sample micro-volume UV-Vis spectrophotometer. With the NanoDrop 8000, you can measure more samples in less time with the same reliability and patented sample retention technology of the NanoDrop 2000.

Specifications:

  • Absorbance Accuracy: 3% (at 0.74 Abs at 350nm)
  • Absorbance Range: 0 - 75Abs
  • Accuracy: 0.003 *SD of 10 individual measurements at 0.74Abs
  • Accuracy (Absorption): 3% (at .74 at 350nm)
  • Applications: Nucleic acid, protein, cell culture and custom methods
  • Certifications/Compliance: UL/CSA and CE
  • Detection Limits: 2.5 ng/µL (dsDNA), 0.15 mg/mL (BSA)
  • Detection Range: 2.5-3,700 ng/µL (dsDNA), 0.15 - 100 mg/mL (BSA)
  • Detector Type: 2048-element linear silicon CCD array
  • Footprint: 24 x 32 cm
  • Lamp: Xenon Flash Lamp
  • Measurement Time: <20 sec.
  • No. of Samples: Up to 8
  • Pathlength: 0.1, 0.2 and 1.0 mm
  • Sample Volume: 1µL
  • Spectral Resolution: ≤3 nm (FWHM at Hg 546.1 nm)
  • Voltage: 12VDC
  • Wattage: ±1 nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Range: 220 - 750 nm
  • Weight: 3.4 kg
Learn More
-NanoDrop-8000--21640
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma NanoDrop 8000 Spectrophotometer UV/Vis Reader

Thermo Forma NanoDrop 8000 Spectrophotometer UV/Vis Reader

Cambridge ID #: 20772

Description:

Thermo Scientific™ NanoDrop 8000 is a muti-sample micro-volume UV-Vis spectrophotometer. With the NanoDrop 8000, you can measure more samples in less time with the same reliability and patented sample retention technology of the NanoDrop 2000.

Specifications:

  • Absorbance Accuracy: 3% (at 0.74 Abs at 350nm)
  • Absorbance Range: 0 - 75Abs
  • Accuracy: 0.003 *SD of 10 individual measurements at 0.74Abs
  • Accuracy (Absorption): 3% (at .74 at 350nm)
  • Applications: Nucleic acid, protein, cell culture and custom methods
  • Certifications/Compliance: UL/CSA and CE
  • Detection Limits: 2.5 ng/µL (dsDNA), 0.15 mg/mL (BSA)
  • Detection Range: 2.5-3,700 ng/µL (dsDNA), 0.15 - 100 mg/mL (BSA)
  • Detector Type: 2048-element linear silicon CCD array
  • Footprint: 24 x 32 cm
  • Lamp: Xenon Flash Lamp
  • Measurement Time: <20 sec.
  • No. of Samples: Up to 8
  • Pathlength: 0.1, 0.2 and 1.0 mm
  • Sample Volume: 1µL
  • Spectral Resolution: ≤3 nm (FWHM at Hg 546.1 nm)
  • Voltage: 12VDC
  • Wattage: ±1 nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Range: 220 - 750 nm
  • Weight: 3.4 kg
Learn More
Thermo-Forma-NanoDrop-8000-Spectrophotometer-UV-Vis-Reader-20772
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo NanoDrop ND-1000 Spectrophotometer UV/Vis Reader

Thermo NanoDrop ND-1000 Spectrophotometer UV/Vis Reader

Cambridge Scientific ID #'s: 20555, 20771

Includes:
• Computer w/ Software
• Necessary Cables
• Manual

The NanoDrop 1000 Spectrophotometer measures 1 ul samples with high accuracy and reproducibility. The full spectrum (220nm-750nm) spectrophotometer utilizes a patented sample retention technology that employs surface tension alone to hold the sample in place. This eliminates the need for cumbersome cuvettes and other sample containment devices and allows for clean up in seconds. In addition, the NanoDrop 1000 Spectrophotometer has the capability to measure highly concentrated samples without dilution (50X higher concentration than the samples measured by a standard cuvette spectrophotometer).

UV/VIS spectrophotometry is simple for samples as small as 1 ul using the NanoDrop 1000 Spectrophotometer. The small sample requirement and ease of use make the NanoDrop 1000 Spectrophotometer ideally suited for measuring:
• Nucleic acid concentration and purity of nucleic acid samples up to 3700 ng/ul (dsDNA) without dilution
• Fluorescent dye labeling density of nucleic acid microarray samples
• Purified protein analysis (A280) up to 100 mg/ml (BSA)
• Expanded spectrum measurement and quantitation of fluorescent dye labeled proteins, conjugates, and metalloproteins
• Bradford Assay analysis of protein
• BCA Assay analysis of protein
• Lowry Assay analysis of protein
• Pierce Protein 660 nm Protein Assay
• Cell density measurements
• General UV-Vis spectrophotometry

Specifications:

  • Sample Size: 1 microliter
  • Path Length: 1 mm (with auto-ranging to 0.2 mm)
  • Light Source: Xenon flash lamp
  • Detector Type: 2048-element linear silicon CCD array
  • Wavelength Range: 220-750 nm
  • Wavelength Accuracy: 1 nm
  • Wavelength Resolution: 3 nm (FWHM at Hg 546 nm)
  • Absorbance Precision: 0.003 absorbance ( 1mm path)
  • Absorbance Accuracy: 2% (at 0.76 absorbance at 257 nm)
  • Absorbance Range: 0.02-75 (10 mm equivalent absorbance)
  • Detection Limit: 2 ng/microliter (dsDNA)
  • Maximum Concentration: 3700 ng/microliter (dsDNA)
  • Measurement Cycle Time: 10 seconds
  • Dimensions: 14 cm X 20 cm
  • Weight: 1.6 kg
  • Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
  • Operating Voltage: 12 Vdc
  • Operating Power Consumption: 6 W
  • Standby Power Consumption: 1.5 W Heating : 37 ± 0.5 °C
Learn More
Thermo-NanoDrop-ND-1000-Spectrophotometer-UV-Vis-Reader-20555
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Victory Scientific Picodrop *NEW* Microliter Spectrophotometer

Victory Scientific Picodrop *NEW* Microliter Spectrophotometer

Cambridge ID #: 21048

Features:

  • Quantify RNA, DNA and Proteins in just 3 seconds
  • Low operating costs
  • Measures nucleic acid samples down to 3 ng/μl, and proteins to 0.1 mg/ml
  • Tests samples in volumes as low as 1 - 2 μl - no need to dilute!
  • Purchase includes P10 micropipette and a box of 96 UVpette tips
  • No additional calibration needed (auto calibrating)
  • Zero cross contamination and recover 100% of sample

Specifications:

  • Light Source: Pulsed Xenon
  • Detector: UV coated CCD with 2048 pixels
  • Absorbance Range: 0.0 - 25 absorbance units
  • Absorbance Accuracy: 1% (at .76 absorbance at 257 nm)
  • Sample Size: 2.0 ul, absolute volume not critical, max. 10 ul, accuracy of pipetting not critical
  • Resolution: 3 nm (wavelength resolution FWHM at Hg 546 nm)
  • Wavelength range: 220 - 950 nm
  • W×D×H: 14×27×38 cm
Learn More
Victory-Scientific-Picodrop-*NEW*-Microliter-Spectrophotometer-21048
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Section Flotation Bath Section Bath

Thermo Section Flotation Bath Section Bath

Cambridge ID #: 18657

Description:

The flotation bath holds water at a constant temperature to flatten wax or resin sections prior to lifting them onto a microscope slide, and can be used for hot staining except with corrosive substances. The top rim of the unit has generous space for drying slides. The controls have been recessed to provide an added measure of safety. There is a drop-on stainless steel lid to provide a cover to the bowl when not in use. It has a deep tapered bowl made from stainless steel to offer maximum resistance against corrosion. Both the bowl and the upper casing have a matte-black PTFE coating providing visual contrast against wax sections. The lower steel casing has a resistant epoxy coating. The power cable has moduled connections at both terminals. The power inlet socket at the back of the unit has fuses on both the negative and positive lines for optimum protection.

 

Specifications:

 

  • Temperature range: 30 to 65 ± 1.5 at 20 ambient
  • Dimensions, external (WxDxH), mm: 275 x 325 x 107
  • Dimensions, (Bowl diameter x depth) mm: 222 x 85
  • Mass, kg: 3.75
  • Electrical supply: 220 to 240V 50/60Hz
Learn More
Thermo-Section-Flotation-Bath-Section-Bath-18657
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek Synergy Neo Microplate Readers

BioTek Synergy Neo Microplate Readers

Cambridge ID #: 20804

Synergy Neo is a patented HTS multi-mode microplate reader designed specifically for today’s screening and core laboratories. Neo has all the features expected in an HTS screening instrument, including multiple parallel detectors for ultra-fast measurements and a dedicated filter-based optical system for live cell assays. With a transfer time of about 6 seconds per plate, Neo’s available plate stacker is the fastest on the market, allowing walk-away automation for short- or long-term assays. Synergy Neo also meets today’s diverse assay requirements by incorporating features such as a powerful 100 mW laser-based excitation source for Alpha assays, a unique patented hybrid optical design, advanced temperature control to 65 °C, orbital and linear shaking. Ease of use and user confidence are key to the design of Synergy Neo’s unique filter cubes that are barcoded for positive filter ID – limiting the possibility of errors and streamlining the workflow, while an available camera-based barcode reader can scan both 1D and 2D barcode-labeled plates. The outstanding functionality of Synergy Neo is controlled by the powerful, yet easy to use, Gen5™ Data Analysis Software. If you are involved in the HTS screening world, Synergy Neo was designed just for you.

Features:

  • Dual PMT head for ultra fast FP and TR-FRET measurements
  • 6 seconds to read a 96-well plate, 11 seconds for a 384-well plate
  • Ultra-fast microplate stacker (6 second plate swap time)
  • Optional 680 nm laser for Alpha assays
  • Patented Hybrid Technology™ optical system; mono and filters for both top and bottom detection
  • Dedicated filter-based optical system for cell-based assays
  • Fast and sensitive luminescence detection
  • Optional microplate barcode reader
  • Positive identification of filter cubes with barcode system
  • Compatible with Take3 Micro-Volume Plates for 2 µL samples

 

Learn More
BioTek-Synergy-Neo-Microplate-Readers-20804
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee T3 *NEW* Spectrophotometer UV/Vis Reader

Persee T3 *NEW* Spectrophotometer UV/Vis Reader

Cambridge ID #: 21341

Features:

The T3 portable spectrometer is a compact portable instrument based on advanced CCD detection technology.

This highly compact instrument boasts all the features of a conventional bench-top spectrophotometer including Spectrum Scanning, Photometric, Quantitative and Kinetic methods.

Due to its portable design, it is also ideal for field monitoring and on-site operations for water and food analysis.

Pre-programmed test methods including calibration data for the Spectroquant series of reagent test kits from Merck Chemicals.

 

  • Ruggedized case
  • 2GB memory for data and method storage, support USB flash memory
  • Easy to use with multiple interface including USB, RS232, Ethernet
  • GPS positioning and GPRS mobile wireless data transmission (by SIM card)
  • Lithium battery continuously work for 6 hours after fully charged
  • Measure with cuvettes, test tube or optical fiber probe, work with a number of lab supplies as optional accessories to be a mobile lab

Specifications:

  • Light source: Convergent tungsten lamp, 500 hrs of service life
  • Measurement modes: Spectrum scan, quantitative measurement, kinetics measurement, photometric measurement
  • Monochromator: Flat-field holographic concave grating
  • Detector: CCD 1L x 511 2048 pixel
  • Sampling accessories: Insert optic fiber probe, 10 mm and 20 mm pathlength tips; rectangular cuvette holder; cylindrical test tube holder
  • Power supply: Built-in battery, continuously work for 6 hours after being charged
  • Vehicle power: supply adapter (optional)
  • Batterycharger: 90-240 V
  • Printer: Micro printer (optional), support USB printer (PLC language)
  • Operating system: Windows embedded CE 6.0 with 2 GB memory and timing function
  • Input/display: 480 x 272 colour touch operation or mouse operation
  • Wavelength range: 380-800 nm
Learn More
Persee-T3-*NEW*-Spectrophotometer-UV-Vis-Reader-21341
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Invitrogen Tali T10791 Cytometer

Invitrogen Tali T10791 Cytometer

Cambridge ID #: 18329

The Tali Image-Based Cytometer is a 3-channel (bright field, green fluorescence, red fluorescence) benchtop assay platform that uses state-of-the-art optics and image analysis to perform assays for cells in suspension, including GFP and RFP expression, apoptosis, cell viability (live, dead, and total cells), cell cycle, and cell counting assays. It is compatible with a wide variety of eukaryotic cells. In addition to the bright field channel, the Tali® Image-Based Cytometer features two fluorescent channels (green and red), enabling it to simultaneously count green or red fluorescent stains, as well as cells expressing GFP and RFP.

 

Specification:

 

  • Instrument type: Benchtop cell counter and suspension cell-based assay platform
  • Dimensions (W x D x H): 11.5 x 17.5 x 11.5 in.
  • Weight: 19.4 lbs
  • Operating power: 100–240 VAC, 2.5 A, 120 V
  • Frequency: 50/60 Hz
  • Electrical input: 12 VDC, 13 A
  • Installation site: Indoor use only, Class A environments; pollution degree 2
  • Operating temperature: 10 - 40°C
  • Operating humidity: < 80% (non-condensing)
  • Processing time: 10 seconds to 2 minutes, depending on the number of fields captured
  • Sample concentration range: 1 x 10^5 - 1 x 10^7 cells / mL
  • Particle/cell diameter range: 5-60 µm
  • Required sample volume: 25 µL
  • Firmware: Tali Image-Based Cytometer Firmware
  • USB drive: 4 Gigabyte
  • Optics: 3 channels (bright field, green fluorescence, red fluorescence)
  • Excitation: Green channel LED (458 ± 20 nm), Red channel LED (530 ± 20 nm)
  • Green channel filter: 466/40 EX, 495 LP Di, 525/50 EM
  • Red channel filter: 543/22 EX, 580 LP Di, 585 LP EM
  • Camera: 1.3 Mega pixels, 4x objective, 4x or 16x digital zoom
Learn More
Invitrogen-Tali-T10791-Cytometer-18329
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Victory Scientific UF150 *NEW* Real-Time qPCR System

Victory Scientific UF150 *NEW* Real-Time qPCR System

Cambridge ID #: 21049

Features:

  • QPCR: UF-150 GENECHECKER Ultra-Fast Real-time PCR System

Specifications:

  • Operating Mechanism : Precise Control of Peltier Element

  • Temperature Accuracy : ± 0.5°C 

  • Temperature Uniformity : ± 0.5°C (Well to Well)

  • Temperature Stability : ± 0.5°C 

  • Ramping Rate : 8.0°C / second 

  • Temperature Range : 35 ~ 65  (1.0°C Increment) for RT Step   20 ~ 99  (1.0°C Increment) for PCR 

  • Sample Format : Polymer Based 3-Dimensional Microfluidic Chip

  • Number of Samples per Run : 10 

  • Required Sample Volume : 10μl 

  • Typical PCR Duration : Less than 12 Minutes for 30 Cycles (without RT Step)

  • Method of Detection : Comparison of Digitized Fluorescence

  • Signal Display : Text LCD (4 Line) 

  • Integrated Memory : Saves up to 12 PCR Protocols  

  • Type of Excitation : High Brightness LED 

  • Wavelength : 465nm ± 10nm  

  • Number of Detection Channel : 1 

  • Method of Fluorescence Measurement : Integrated Camera Module 

  • PC Connection : USB 2.0 A to B (PC to Device, Only available through GENERECORDER)

  • Power (Wattage) : AC 110-230V (50-60Hz) Input / DC 12V Output (70W) 

  • Dimension / Weight : 200(w) x 200(d) x 125(h) mm / 3.2kg

Learn More
Victory-Scientific-UF150-*NEW*-Real-Time-qPCR-System-21049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Universal Hood Gel Imaging System

Bio-Rad Universal Hood Gel Imaging System

Cambridge Scientific ID #'s: 20491, 7152
"

Features:

 

The Biorad Universal Hood II Gel Doc is an easy-to-use, high-performance system that captures images in real time, allowing you to more accurately position and focus on your sample. The Gel Doc system combines a compact darkroom, UV-transilluminator workstation, CCD camera, motorized zoom lens, and user-friendly Quantity One software to document and quantitate gels stained with ethidium bromide and other fluorophores. The iris, zoom, and focus of the lens can be manipulated either onscreen within Quantity One software or by the instrument control panel. With Biorad's intuitive software, images acquired with the Gel Doc can be rapidly optimized, annotated, analyzed, and printed.




Specifications:

 

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 25 x 26 cm
  • Excitation source: Trans UV 302, 254, 365 nm & White, Epi-White light
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: CCD
  • CCD resolution (H x V): 768 x 494 RS-170  752 x 582 CCIR
  • Pixel size in microns (H x V): 8.4 x 9.8
  • Filter holder: 2 positions (1 Emmision Filter, 1 Chemi)
  • Emission filters: 1 included (amber), 4 optional
  • Dynamic range: 1.8 Orders
  • Pixel density (gray levels): 8 bit (256 gray levels)
  • Dynamic flat fielding: No
"
Learn More
Bio-Rad-Universal-Hood-Gel-Imaging-System-20491
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping