Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Cell Analyzer: 16-30 of 201

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Savant Fastprep FP120 Cell Disruptor

Savant Fastprep FP120 Cell Disruptor

Cambridge ID #: 21039

Features:

The FastPrep® FP120 is a high-speed, benchtop reciprocating device for efficient
disruption of cell membranes. The unit is designed for use with the FastPrep®
Extraction Kits (Qbiogene, www.qbiogene.com). These kits are available for a
wide variety of extraction and purification applications.

Specifications:

  • Controls: Programmable run time and speed; large LED readout
  • Time: Range: 1-45 sec/ Programmable in 1 sec increments
  • Speed: Range: 4.0-6.5m/sec/ Programmable in 0.5 m/sec increments
  • Acceleration: < 2 seconds to maximum speed
  • Deceleration: < 2 seconds to maximum speed
  • Dimensions (W*D*H): 11 in x 15.75 in x 12 in
Learn More
Savant-Fastprep-FP120-Cell-Disruptor-21039
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 NC-200 Cell CounterImage Coming Soon

NC-200 Cell Counter

Cambridge ID #: 22008

Specifications:

 

  • Loading time: App. 60 ul
  • Measurement volume: 1.4 ul
  • Analysis time: 50 sec (one step), 120 sec (two step)
  • Dimensions: 38 x 26 x 22 cm (W x H x D)
  • Weight: 6.7 lb (3 kg)
Learn More
-NC-200-Cell-Counter-22008
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Protean i12 IEF Cell

Bio-Rad Protean i12 IEF Cell

Cambridge ID #: 22743

The PROTEAN i12 IEF system is designed for isoelectric focusing (IEF) proteins in immobilized pH gradient (IPG) strips for the first dimension of two-dimensional (2-D) electrophoresis. The PROTEAN i12 IEF cell can run 1–12 IPG strips in 7, 11, 13, 17, 18, or 24 cm focusing trays. Each channel in the isoelectric focusing tray is independently powered, enabling precise control over each IPG strip. This feature makes it possible to run different sample types, different pH gradients, and multiple protocols simultaneously.

 

Specifications:

  • User Interface: Display QVGA resolution (320 x 240) touch screen or mouse control
  • Programmable: Yes
  • Ramping: Step, linear, gradual, and hold voltage ramping for each focusing step. Hold mode as a final step to prevent diffusion when IEF is complete
  • Protocol Capacity: 2 GB
  • Data collection: .dat format
  • Dimensions:3 in x 13.6 in x 15.1 in
  • Weight: 19 lbs
  • Input power: 100–240 VAC, 50/60 Hz
Learn More
Bio-Rad-Protean-i12-IEF-Cell--22743
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Trans-Blot SD  Semi-Dry Transfer Cell

Bio-Rad Trans-Blot SD Semi-Dry Transfer Cell

Cambridge Scientific ID #'s: 16546, 10519

Features and Benefits

 

  • Transfers take place in as little as 15–60 min
  • Minimal buffer requirements save money
  • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
  • Single-step locking system allows simple, speedy setup
  • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
  • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
  • Safety cover breaks the electrical current when lifted, preventing electrical shock

 

Applications and Uses

 

  • Western blotting
  • Nucleic acid transfer
  • Northern and Southern blot transfers in 10–35 min
  • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

 

Features:

 

  • Maximum gel size (W x L), cm: 24 x 16
  • Buffer requirement, ml: 200
  • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
  • Recommended power supply: PowerPac HC (High Current)
  • Dimensions (W x L x H), cm: 37 x 24 x 11
  • Weight, kg/lb: 3.6/7.9
Learn More
Bio-Rad-Trans-Blot-SD-Semi-Dry-Transfer-Cell-16546
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

Cambridge ID #: 22386

The Trans-Blot Turbo transfer system reduces western blotting setup time to 1 minute and transfer to as little as 3 without sacrificing sensitivity.

Paired with Trans-Blot Turbo transfer packs or Trans-Blot RTA kits, this system provides a complete solution for fast, high-efficiency transfer of even high molecular weight proteins.
Used on its own or as part of the V3 Western Workflow, the Trans-Blot Turbo system is the no-compromise solution for high-performance western blotting.

Features:

  • Fast Transfer Times: Transfer your proteins in as little as 3 minutes.
  • High Throughput: Transfer up to 4 mini or 2 midi gels simultaneously.
  • Flexible Design: Easily customize transfer conditions; compatible with traditional semi-dry consumables.
  • Ease of Use: Reduce set-up time to only 1 minute from opening the gel cassette to starting the transfer.
  • Two Blotting Sandwich Options: Trans-Blot Turbo Transfer Packs or Trans-Blot Ready-to-Assemble Kits
Learn More
Bio-Rad-Trans-Blot-Turbo-System-Semi-Dry-Transfer-Cell-22386
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  FC5816 *NEW* Benchtop Centrifuge

Ohaus FC5816 *NEW* Benchtop Centrifuge

Cambridge ID #: 20272

Features:

Frontier 5000 Multi Pro Centrifuges are designed for universal use in research, industrial & clinical laboratories, and can be combined with our rotors & accessories for customized use in specific applications. Available in 5 models with capacities from low microliter to 6x250 ml, and featuring high-speed performance at maximum volume, automatic rotor identification and safety features - these multi-purpose centrifuges are a must for any lab.

Applications

Centrifugal Separation, General Sample Preparation, Cell Pelleting, Protein Separation, Nucleic Acid Separation, Cell Concentrating, Chemical Separation, Diagnostics, Environmental Sample Preparation, Blood Sample Processing

Display

Backlit Liquid Crystal Display (LCD)

Operation

Designed to be used with a variety of rotors and accessories

Communication

N/A

Construction

Corrosion-resistant stainless steel chamber with Polycarbonate/ABS plastic lid

Design Features

Ten acceleration & deceleration rates, selection of running time from 10s to 99h 59min or continuous, quick spin, CFC-free refrigeration system, sample temp. indication (refrigerated models), lid-locking system, over-speed protection, dual imbalance sensing

 

Specifications:

 

 

  • Speed Range:200 rpm – 15,000 rpm
  • Maximum Relative Centrifuge Force (x g):21,379 g
  • Maximum Capacity (Rotor):6x250 ml
  • Acceleration Gear:10
  • Deceleration Gear:10
  • Dimensions (HxLxW):13.94 in x 21.18 in x 17.56 in (354 mm x 538 mm x 446 mm)
  • Display: LCD with backlight
  • Net Weight:115 lb (52 kg)
  • Noise Level:≤61±2 dB(A)
  • Power Consumption: 520 W
  • Rotor Recognition Method: Auto
  • Running Time: Quickspin;  10 sec to 99 h 59 min 59 sec;  Continous
  • Safety Certification: CE;  FCC
  • Working Environment:36°F – 95°F, 80%RH, non-condensing (2°C – 35°C, 80%RH, non-condensing)

 

 

Learn More
Ohaus-FC5816-*NEW*-Benchtop-Centrifuge-20272
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  VXMPAL *NEW* Vortexer

Ohaus VXMPAL *NEW* Vortexer

Cambridge ID #: 20247

Features:

OHAUS Microplate Vortex Mixers are perfect for mixing microplates throughout the speed range. All models are designed for continuous-duty use in the lab. Digital models offer a timer and exact speed control for applications that demand repeatable results and non-digital variable speed models are an economical alternative. The high-speed and small orbit of these mixers make them optimal for effectively mixing microplates.

Applications

ELISA Assays, PCR Preparations, Digestions, Cell Disruptions

Display

Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)

Operation

Detachable 3-wire cord and plug (included)

Communication

N/A

Construction

Cycoloy

Design Features

Microplate adapter and cup head (included)

 

Specifications:

 

 

  • Control:Analog
  • Duty Rating:Continuous
  • Orbit:0.1 in (3.5 mm)
  • Speed Range:On Mode, 300 rpm – 2500 rpm;  Touch Mode, 300 rpm – 3500 rpm
  • Capacity:2 Microplates
  • Dimensions (HxLxW):4.5 in x 10.5 in x 5.4 in (11.4 cm x 26.7 cm x 13.7 cm)
  • Net Weight:11.7 lb (5.3 kg)
  • Power:120V, 0.25A, 50/60Hz
  • Power Consumption:30 W
  • Safety Certification:TUV

 

  • Working Environment:39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing)
Learn More
Ohaus-VXMPAL-*NEW*-Vortexer-20247
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge ID #: 16000

 The Agilent 1100 HPLC G1321A Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.

Specifications:

  • Dimensions: 5 x 13.5 x 17 in
  • Weight:5 lbs
  • Environment:0 to 40°C at <95% humidity
  • Performance:10 fg Anthracene, Ex=250 nm, Em=400 nm*
  • Performance:RAMAN (H2O) > 200 (FLF rev A)
  • Performance:RAMAN (H2O) > 400 (FLF rev >A)
  • Performance:Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds response time)
  • Pulse Frequency:296Hz (single signal mode), 74Hz (spectral mode)
  • Excitation Monochromator Range:200 nm - 700 nm
  • Excitation Monochromator Bandwidth:20 nm
  • Emission Monochromator Range:280 nm - 900 nm
  • Emission Monochromator Bandwidth:20 nm
  • Spectrum Acquisition Scan Speed:28 ms/datapoint
  • Wavelength Characteristic Repeatability:+/- 0.2 nm
  • Wavelength Characteristic Accuracy: +/- 3 nm
  • Flow cells: 8 uL (standard) and 20 bar (2MPa) pressure maximum
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-16000
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 16041, 22114, 17969, 13408, 16314, 16001, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1321A HPLC Fluorescence Detector

Hewlett Packard 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge ID #: 22335

 The 1100 HPLC G1321A Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.

Specifications:

  • Dimensions: 5 x 13.5 x 17 in
  • Weight:5 lbs
  • Environment:0 to 40°C at <95% humidity
  • Performance:10 fg Anthracene, Ex=250 nm, Em=400 nm*
  • Performance:RAMAN (H2O) > 200 (FLF rev A)
  • Performance:RAMAN (H2O) > 400 (FLF rev >A)
  • Performance:Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds response time)
  • Pulse Frequency:296Hz (single signal mode), 74Hz (spectral mode)
  • Excitation Monochromator Range:200 nm - 700 nm
  • Excitation Monochromator Bandwidth:20 nm
  • Emission Monochromator Range:280 nm - 900 nm
  • Emission Monochromator Bandwidth:20 nm
  • Spectrum Acquisition Scan Speed:28 ms/datapoint
  • Wavelength Characteristic Repeatability:+/- 0.2 nm
  • Wavelength Characteristic Accuracy: +/- 3 nm
  • Flow cells: 8 uL (standard) and 20 bar (2MPa) pressure maximum
Learn More
Hewlett-Packard-1100-Series---G1321A-HPLC-Fluorescence-Detector-22335
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17971, 13182, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17971
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Cambridge ID #: 20340

Features:

  • Advanced temperature controlled detector optics ready to use within two hours of installation
  • Automatic zero and automatic purge combined with a recycle valve for automatic solvent recycling allow uninterrupted operation
  • Automatic light intensity control circuit to ensure the optimum performance of the optics
  • Integrated diagnostics for efficient troubleshooting
  • Built-in refractive index calibration
  • Front access to valves and capillaries for easy maintenance
  •  

Specifications:

  • Detection type: Refractive Index
  • Refractive index range: 1.00 – 1.75 RIU, calibrated
  • Measurement range: +/- 600 x 10-6 RIU
  • Optics temperature control: 5 ° C above ambient to 55 ° C
  • Sample cell volume: 8uL
  • Maximum pressure: 5 bar (0.5Mpa)
  • Maximum flow rate: 5mL/minute
  • Valves: Automatic purge and automatic solvent recycle
  • Volumes: Inlet port to sample cell 62uL, inlet port to outlet port 590uL
Learn More
Agilent-1200-Series---G1362A-HPLC-Refractive-Index-Detector-20340
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G4212B HPLC Diode Array Detector

Agilent 1260 Infinity Series- G4212B HPLC Diode Array Detector

Cambridge ID #: 19978

Features:

The Agilent 1260 Infinity II Diode Array Detector WR offers multiple wavelengths and full spectral detection at up to120 Hz sampling rate, keeping up with the analysis speed of fast LC. Even at high data rates, the 1260 Infinity II DAD WR enables precise identification, quantification, and peak purity analysis at trace levels. Maximum flexibility is guaranteed with a wide wavelength range of 190 to 950 nm with dual-lamp design, as well as the choice of 12 analytical, preparative and SFC flow cells.

Specifications:

  • Fast data acquisition - full spectral data acquisition rate of 120 Hz increases resolution and delivers fast, highly sensitive peak purity analysis and spectral confirmation – at trace levels.
  • Highest sensitivity - dual lamp design allows analysis of wavelengths between190 to 950 nm.
  • Simultaneous data acquisition - The diode array design enables simultaneous acquisition of up to eight compound-specific wavelengths for increased sensitivity and selectivity.
  • Rapid optimization of sensitivity, linearity and spectral resolution-programmable slit (1 to 16 nm) provides optimum incident light conditions.
  • Eliminates background interference- with reference wavelengths.
  • Minimized short-term noise (< ± 7 µAU ASTM) - low noise front-end electronics and special flow cell design deliver lowest detection limits.
  • Maximum flexibility, compatibility and investment protection – with a range of 12 analytical, preparative and SFC flow cells.

.

Learn More
Agilent-1260-Infinity-Series--G4212B-HPLC-Diode-Array-Detector-19978
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Series - G4212B HPLC Diode Array Detector

Agilent 1260 Series - G4212B HPLC Diode Array Detector

Cambridge Scientific ID #'s: 19936, 20798

The 1290 Infinity Diode Array Detector (DAD) features a completely new optical design based on the Agilent Max-Light cartridge cell with optofluidic waveguides. With typical detector noise levels of < ± 0.6 μAU/cm the revolutionary 6 cm flow cell gives up to 10 times higher sensitivity than the 1200 Series DAD and VWD.  Any compromising refractive index and thermal effects are almost completely eliminated,

resulting in significantly less baseline drift for more reliable and precise peak integration. For ultra high productivity the 1290 Infinity DAD offers multiple wavelength and full spectral detection at sampling rates up to 160 Hz.

 

Features:

  • Ultra sensitivity through revolutionary Agilent Max-Light cartridge cell with 60 mm
  • optical path length (typically noise: < ± 0.6 μAU/cm).
  • Universal Agilent Max-Light cartridge standard cell with 10 mm optical path length
  • provides high sensitivity (noise: < ± 3 μAU) and lowest peak dispersion for 2.1, 3
  • and 4.6 mm ID columns.
  • Programmable slit from 1 to 8 nm provides optimum incident light conditions for
  • rapid optimization of sensitivity, linearity and spectral resolution.
  • Multiple wavelength and full spectral detection at high sampling rate of 160 Hz,
  • keeping pace with fastest possible analysis speed.
  • More reliable and robust peak integration process due through less baseline drift.
  • Full spectral detection for compound identification by spectral libraries or verification
  • of the separation quality with peak purity analysis for ultra fast LC. Simultaneous
  • detection of up to 8 signals for increased sensitivity and selectivity.
  • Wide linear range (typically up to 2.5 AU) – for reliable, simultaneous quantification
  • of primary compounds, by-products and impurities.
  • Radio frequency identification (RFID) technology for flow cells and lamp provide
  • new levels of data security and traceability.
  • Electronic temperature control (ETC) provides maximum baseline stability and
  • practical sensitivity under fluctuating ambient temperature and humidity conditions.
  • Reference wavelength for elimination of background interference.
Learn More
Agilent-1260-Series---G4212B-HPLC-Diode-Array-Detector-19936
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping