We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Column Selector: 1-15 of 65

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Rheodyne EV500-104 Column SelectorImage Coming Soon

Rheodyne EV500-104 Column Selector

Cambridge ID #: 13432

The EV platform continues to offer classic column selectors and other liquid-end possibilities in a stand-alone ready-to-use unit.

Specifications:

  • Differential Pressure Maximum: 5000 psig
  • Positions: 6
  • Ports: 14
Learn More
Rheodyne-EV500-104-Column-Selector-13432
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perseptive Biosystems Scout Column SelectorImage Coming Soon

Perseptive Biosystems Scout Column Selector

Cambridge ID #: 6962

Description:

Applied Biosystems’ SCOUT Column Selector is an automated multi-column switching unit for use with the BioCAD family of workstations and the INTEGRAL 100Q System. The SCOUT Column Selector allows flow to be diverted to any one of six attached columns. The SCOUT Column Selector offers increased flexibility for both systematic methods development and routine execution of experiments.

Specifications:

  • Valve body/fluid paths: PEEK, carbon-filled PEEK, PTFE, or HMW polyketone
  • Maximum pressure: 3,000 psi
  • Back pressure: <100 psi at 60 ml/min for each line
  • Column sizes: Up to 24 mm diameter and up to 30 cm length
  • Plumbing: 1/16-inch Valco fittings
  • Dimensions (W x L x H): 9.5 in. x 12 in. x 8 5/16 in. (24.1 cm x 30.5 cm x 21.1 cm)
  • Weight: 10 lbs. (4.5 Kg)
  • Power requirements: 100 V/120 V/220 V/240 V, 50/60 Hz, 1.2 amps
  • Fuse rating: 2-amp SLO-BLO
  • Operating temperature: 4°C to 40°C
  • Operating humidity: 10 to 90% non-condensing
Learn More
Perseptive-Biosystems-Scout-Column-Selector-6962
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity H Class Column Manager UPLC Column Manager

Waters Acquity H Class Column Manager UPLC Column Manager

Cambridge ID #: 15342

Specifications:

  • Column capacity:
    • CM-A: Two columns, as standard (maximum length of 150 mm with filter or guard column)
    • or four columns (maximum length of 50 mm) can be supported with optional tubing kit,
    • up to 4.6 mm internal diameter (1.0.)
    • CM-Aux: Two columns (maximum length of 150 mm, with filter or guard column) - up to
    • two CM-Aux units can be configured with one CM-A for support of up to six columns
  • Switching valves: Two nine-port, eight-position valves (CM-A only); provides programmable, automatic, random access switching, waste and bypass positions for rapid solvent changeover
  • Temperature Range:
    • 0 to 90.0 ·C, set table in 0.1 ·C increments
    • Two independent heatl cool zones per module, up to six zones in stacked configuration
  • Temperature Accuracy: ±0.5 ·C
  • Temperature Stability: ±0.3 ·C
  • Solvent conditioning: Active pre-heating as standard
  • Column tracking: eCord Technology column information management tracks and archives column usage history
  • 20 support: Optional
Learn More
Waters-Acquity-H-Class-Column-Manager-UPLC-Column-Manager-15342
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Compartment HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Compartment HPLC Column Compartment / Heater

Cambridge ID #: 9245

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Compartment-HPLC-Column-Compartment---Heater-9245
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Heater Module. HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Heater Module. HPLC Column Compartment / Heater

Cambridge ID #: 7394

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Heater-Module.-HPLC-Column-Compartment---Heater-7394
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Water Heater HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Water Heater HPLC Column Compartment / Heater

Cambridge ID #: 8911

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Water-Heater-HPLC-Column-Compartment---Heater-8911
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 14782, 14774, 13938, 13993, 14001, 17470, 14783, 15133, 17963, 13800, 19167, 16143, 14767, 16318

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment---Heater-14782
By clicking below we can further assist you with your inquiry. Inquire 14 In Stock Worldwide Shipping
Agilent 1100 Series - G1316D HPLC Column Compartment / Heater

Agilent 1100 Series - G1316D HPLC Column Compartment / Heater

Cambridge ID #: 17701

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316D-HPLC-Column-Compartment---Heater-17701
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Cambridge ID #: 17898

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment---Heater-17898
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - K1316C HPLC Column Compartment / HeaterImage Coming Soon

Agilent 1290 Series - K1316C HPLC Column Compartment / Heater

Cambridge ID #: 17707

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---K1316C-HPLC-Column-Compartment---Heater-17707
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 186001863 HPLC Column Compartment / HeaterImage Coming Soon

Waters 186001863 HPLC Column Compartment / Heater

Cambridge ID #: 13073

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-186001863-HPLC-Column-Compartment---Heater-13073
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Alliance - WAT270852 HPLC Column Compartment / Heater

Waters Alliance - WAT270852 HPLC Column Compartment / Heater

Cambridge ID #: 7673

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Alliance---WAT270852-HPLC-Column-Compartment---Heater-7673
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex AS50 HPLC Column Compartment / HeaterImage Coming Soon

Dionex AS50 HPLC Column Compartment / Heater

Cambridge ID #: 18396

The Dionex Autoselect™ AS50 Autosampler precisely delivers from 1.0 to 99.9 µL (in 0.1 µL increments) or 100 to 1000 µL (in 1 µL increments) of sample to an injection valve. Two types of trays are available for sample vials: one for 2 mL vials and one for 10 mL vials. During sampling, the tray remains stationary and a sampling needle arm moves from vial to vial. Up to 99 injections can be taken from each vial. The AS50 can be controlled locally, from the front panel keypad and display, or remotely, with a personal computer running Chromeleon software installed. The AS50 can be configured with PEEK flow paths and components for ion chromatography (IC) applications, or with stainless steel flow paths and components for high-performance liquid chromatography applications (HPLC).

 

Specification:

 

  • Ambient Operating Temperature: 10 °C to 40 °C (50 °F to 104 °F)
  • Operating Humidity: 10% to 95% relative humidity, non-condensing
  • Decibel Level: <60 db (at “A WEIGHING” setting)
  • Dimensions: 58 cm high x 30 cm wide x 46 cm deep (23 in x 12 in x 19 in)
  • Weight: < 30 kg (< 65 lb)
  • Injections Per Vial: 1 to 99

 

  • Variable Volume Range

 

    • 1 to 100 µL in 0.1 µL increments
    • 100 to 1000 mL in 1 µL increments

 

  • Injection Loop Size

 

    • IC version: 25 µL standard; other sizes are available
    • HPLC version: 20 µL standard; other sizes are available
Learn More
Dionex-AS50-HPLC-Column-Compartment---Heater-18396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Hot Pocket HPLC Column Compartment / Heater

Thermo Hot Pocket HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 12891, 12893, 12892

Thermo Scientific HOT POCKET Column Heater offers column heating in a compact, efficient design.

  • Easy to install and use with a variety of column lengths up to 300mm
  • Dual display of both actual and set point temperatures
  • Soft, wrap-around sealing mantle fits directly onto the column

 

Specifications:

  • Temperature range: Just above ambient to 85°C
  • Temperature accuracy: ±2°C with ±0.1°C stability
Learn More
Thermo-Hot-Pocket-HPLC-Column-Compartment---Heater-12891
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Waters TCM HPLC Column Compartment / HeaterImage Coming Soon

Waters TCM HPLC Column Compartment / Heater

Cambridge ID #: 7445

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-TCM-HPLC-Column-Compartment---Heater-7445
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping