Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Denver Instrument: 1-15 of 115

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Denver Instrument TP-1502 Top Loading Balance

Denver Instrument TP-1502 Top Loading Balance

Cambridge ID #: 19416

Features

  • Toggle between two weigh units including grams, milligrams and ounces
  • Automatic external calibration using a precision calibration weight (purchase separately)
  • Helpful programs, such as counting, percent weighing, formulation, average weighing, simplify weighing tasks
  • Stainless-steel weigh pan
  • Overload protection

 

Specifications:

  • Capacity: 1500 g
  • Readability (g): 0.01
  • Repeatability (g): 0.02
  • Weighing Units: g, oz, GN, ct, lb, ozt, tael
  • Calibration Type: External
  • Power Requirements: 115 VAC
Learn More
Denver-Instrument-TP-1502-Top-Loading-Balance-19416
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Denver Instrument TR602 Top Loading Balance

Denver Instrument TR602 Top Loading Balance

Cambridge ID #: 10265

Specifications:

  • Weighing Range: 610g
  • Readability: 0.01g
  • Linearity: 0.01g
  • Repeatability: 0.01g
  • Stabilization Time: 2 sec
  • Pan Dimensions: 6.0”
Learn More
Denver-Instrument-TR602-Top-Loading-Balance-10265
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Denver Instrument XP-300 Top Loading Balance

Denver Instrument XP-300 Top Loading Balance

Cambridge ID #: 13331

XP-Series balances are ideal for educational, industrial and general laboratory weighing where accuracy, portability and affordability are important. The balance contains a rechargeable internal battery, easy to read LCD, multiple weighing units, automatic external calibration, overload protection and percentage weighing.

Specifications:

 

  • Capacity: 300 g
  • Linearity: 0.01 g
  • Readability: 0.01 g
  • Stabilization Time: 3 seconds
  • Dimensions: 8.2 x 8.3 x 2.7 in
  • Power Requirements: 15VDC
  • Weight: 3.75 lbs
  • Pan Size: 5 x 7 inch
  • Taring Range: 0 to 300 g

 

 

Learn More
Denver-Instrument-XP-300-Top-Loading-Balance-13331
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 26231, 9165, 22111, 14496, 21293

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-26231
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

Cambridge ID #: 22470

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Hewlett-Packard-1100-Series---G1311A-HPLC-Quaternary-Pump-22470
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311B HPLC Quaternary Pump

Agilent 1100 Series - G1311B HPLC Quaternary Pump

Cambridge ID #: 19933

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311B-HPLC-Quaternary-Pump-19933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21352

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad ChemiDoc XRS Gel Imaging System

Bio-Rad ChemiDoc XRS Gel Imaging System

Cambridge Scientific ID #'s: 25407, 25369

Includes Computer loaded w/ Image Lab Software

 

The ChemiDoc MP system is a full-feature instrument for gel or western blot imaging. It is designed to address multiplex fluorescent western blotting, chemiluminescence detection, and general gel documentation applications.

Its features are based on CCD high-resolution, high-sensitivity detection technology, and modular options to accommodate a wide range of samples and support multiple detection methods. The system is controlled by Image Lab software to optimize performance for fast, integrated, and automated image capture and analysis of various samples.

 

Features and Benefits

  • Multiple imaging capabilities — the ChemiDoc MP imager can accommodate a variety of sample types and detection methods including multiplex fluorescent western blotting. It is the perfect imager to accompany your protein and DNA electrophoresis runs as well as your western blotting experiments. It delivers quantitative, reproducible results for fluorescence, chemiluminescence, and colorimetric detection
  • Stain-free technology — UV-induced fluorescence labeling of proteins in the stain-free gels allows a 2 hr Coomassie gel-staining protocol to be condensed into a 5 min stain-and-image step. Stain-free gels are western blot compatible — using the V3 Western Workflow™, check your electrophoresis results and blot transfer quality prior to western blotting
  • High-sensitivity blot detection — the ChemiDoc MP imaging system offers advanced detection technology that determines optimal exposure, even for faint or intense samples. Superior sensitivity is achieved for chemiluminescence and multiplex fluorescence detection and for colorimetric gel and blot documentation
  • Superior Image Quality — exceptional dynamic range enables visualization of faint and intense bands on same blot or gel. Images are always in focus at any zoom level to ensure publication-ready images in seconds
  • Ease of Use — precalibrated system provides the precise focus for any zoom setting or sample height; automated hands-free operation ensures consistent, reproducible, and high-throughput performance

 

Applications     

  • Chemiluminescence: Yes
  • Fluorescence: Yes
  • Colorimetry/densitometry: Yes
  • Gel documentation:Yes

Hardware Specifications        

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 26 x 35 cm
  • Maximum image area: (For standard UV-excited gels) 25 x 26 cm
  • Excitation source: Epi-white light and trans-UV (302 nm) are standard (optional 365 nm lamp available); optional trans-white conversion screen, XcitaBlue™ conversion screen, and epi-red, epi-green, and epi-blue LED modules available
  • Illumination control: 8 modes available. Trans-UV, epi-white, and no illumination for chemiluminescence are standard; epi-red, epi-green, epi-blue, trans-white, and XcitaBlue conversion screens are optional
  • Detector: Supercooled CCD
  • Image resolution: 4 megapixels
  • Pixel size (H x V): 6.45 x 6.45 µm
  • Cooling system: Peltier
  • Camera cooling temperature: -30°C absolute and regulated
  • Filter holder: 6 positions (5 for filters, 1 without filter for chemiluminescence)
  • Emission filters: 1 included (standard), 4 optional
  • Dynamic range: >4.0 orders of magnitude
  • Pixel density (gray levels): 65,535
  • Dynamic flat fielding: Application specific; for all applications
  • Instrument size (L x W x H): 36 x 60 x 96 cm
  • Instrument weight: 32 kg

Operating Ranges       

  • Operating voltage: 110/115/230 VAC nominal
  • Operating temperature: 10–28°C (21°C recommended)
  • Operating humidity, noncondensing: <70%

Automation Capabilities         

  • Workflow automated selection: Application driven; user selected or recalled by a protocol
  • Workflow automated execution: Controlled by a protocol via application-specific setup for image area, illumination source, filter, analysis, and reporting
  • Workflow reproducibility: 100% repeatability via recallable protocols; from image capture to quantitative analysis and reports
  • Autofocus (patent pending): Precalibrated focus for any zoom setting or sample height
  • Image flat fielding**: Dynamic; precalibrated and optimizor every application
  • Autoexposure: 2 user-defined modes (intense or faint bands)
Learn More
Bio-Rad-ChemiDoc-XRS-Gel-Imaging-System-25407
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1311A HPLC Quaternary Pump

Agilent 1200 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 24124, 24131, 24716, 24946, 26213, 24754

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-24124
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
 FluorChem SP Gel Imaging SystemImage Coming Soon

FluorChem SP Gel Imaging System

Cambridge Scientific ID #'s: 23904, 26316

Features: 

 

Features for the Photometrics Cool SNAP K4: 

  • 20-MHz readout: High-speed, high-sensitivity image capture
  • 2048 x 2048 imaging array: Resolves fine detail
  • 7.4 x 7.4-ìm pixels: Ideally matched to optical microscope
  • Interline-transfer, progressive-scan CCD: Eliminates camera vibration and facilitates fast triggering
  • Flexible binning and readout: Increases light sensitivity while increasing the frame rate
  • 12-bit digitization: Quantifies bright and dim signals in the same image
  • Thermoelectric cooling: Long integration times for higher sensitivity
  • Enhanced quantum efficiency: Provides higher sensitivity than typical interline cameras
  • C-mount: Easily attaches to microscopes, standard lenses, or optical equipment
  • Acquisition software: Captures, analyzes, and saves high-resolution images
  • PCI interface: High-bandwidth, uninterrupted data transfer
  • PVCam, Circular buffers, Device sequencing: Supported by numerous third-party software packages, Real-time focus, Precise integration with shutters, filter wheels, etc. (Compatible with Windows XP/Vista 32, Mac OS X, and Linux (kernel versions 2.4 and 2.6.8))
  • CCD image sensor: Kodak KAI-4020M; interline-transfer, progressive-scan device with microlenses
  • CCD format: 2048 x 2048 imaging array, 7.4 x 7.4-um pixels, 15.16 x 15.16-mm imaging area (optically centered)
  • Linear full well: 30,000 e- (single pixel); 60,000 e- (2 x 2 binned pixel)
  • Read noise: ≤10 e- rms @ 20 MHz
  • Nonlinearity: <1%
  • Digitizer type: 12 bits @ 20 MHz
  • CCD temperature: -25ͦC (regulated)
  • Dark current : 0.1 e-/p/s @ -25ͦC
  • Operating environment: 0 to 30ͦC ambient, 0 to 80% relative humidity noncondensing
  • I/O TTL (trigger/status): trigger, invert, inhibit, exposing, interline shift, frame readout, 8-bit TTL (programmable), 8-bit DACs(two)

Compare this against “Features of Gel Doc XRS+ system”: 

  • Chemiluminescence: Yes
  • Fluorescence: Yes
  • Colorimetry/densitometry: Yes
  • Gel documentation: Yes  

Hardware Specifications        

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 26X 35 cm
  • Excitation source: Trans-UV and epi-white are standard (302 nm included, with 254 and 365 nm available as options)
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: super cooled CCD
  • Image resolution: 4 megapixels
  • Pixel size (H x V): 6.45 x 6.45 µm
  • Filter holder: 3 positions (2 for filters, 1 without filter)
  • Emission filters: 1 included (standard), 3 optional
  • Dynamic range: >4.0 orders of magnitude
  • Pixel density (gray levels): 65,535
  • Dynamic flat fielding: Application specific, for all applications
  • Instrument size (L x W x H): 36 x 60 x 96 cm
  • Instrument weight: 32 kg

 Operating Ranges         

  • Operating voltage: 110/115/230 V AC nominal
  • Operating temperature: 10–28°C (21°C recommended)
  • Operating humidity: <70% noncondensing

 Automation Capabilities            

  • Workflow automated selection: Application driven; user selected or recalled by a protocol
  • Workflow automated execution: Controlled by a protocol via application specific setup for image area, illumination source, filter, analysis, and reporting
  • Workflow reproducibility: 100% repeatability via recallable protocols; from image capture to quantitative analysis and reports
  • Autofocus: Precalibrated focus for any zoom setting or sample height
  • Image flat fielding: Dynamic; precalibrated and optimized per application
  • Autoexposure: 2 user-defined modes (intense or faint bands)
Learn More
-FluorChem-SP-Gel-Imaging-System-23904
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Beckman Coulter Optima Max 130000 Benchtop Centrifuge

Beckman Coulter Optima Max 130000 Benchtop Centrifuge

Cambridge ID #: 24217

Features:

 

The Optima MAX and MAX-E (see Figure 1-1) microprocessor controlled tabletop ultracentrifuges generate high centrifugal forces for a variety of high-speed applications. The instrument design features a variable-frequency induction drive, the thermoelectric temperature control system, self-purging vacuum system, rotor overspeed identification system, program memory that can contain up to ten five-step programs, and a choice of acceleration and deceleration rates.

 

Manual and programmed operation are available. • In manual operation, you enter the individual run parameters before beginning each run. • In programmed operation, you can duplicate runs quickly and accurately by selecting one of ten programs previously entered into the program memory. Each program can contain up to five steps. User messages and/or audible signals are provided to alert you to conditions that may need attention. An optional feature of the Optima MAX or MAX-E is the RS 232C Interface Accessory, which enables it to be connected to a personal computer. Information about this feature will be supplied upon request.

 

Specifications:

 

Only values with tolerances or limits are guaranteed data. Values without tolerances are informative data, without guarantee.

Speed

  • Set speed:
  • Optima MAX . . . . . . 5 000 to 130 000 rpm in 1 000-rpm increments
  • Optima MAX-E . . . . 5 000 to 100 000 rpm in 1 000-rpm increments
  • Speed control . . . . . . . . . . . . . actual rotor speed, ±50 rpm of set speed
  • Speed display . . . . . . . . . . . . actual rotor speed in 100-rpm increments above 5 000 rpm and 10-rpm increments at speeds below 5 000 rpm

Time

  • Set time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to 99 hours 59 minutes
  • Time display
  • Manual operation . . . . . . . . . . . . . . . indicates run time remaining
  • Programmed operation . . . . . . . . . . . . . . . . time remaining in step
  • Temperature
  • Set temperature . . . . . . . . . . . . . . . . . . . . 0 to 40°C in 0.1° increments
  • Temperature control (after equilibration). . . . . ±2°C of set temperature
  • Temperature display. . . . . . . . . . . . . . . . . . . . . actual rotor temperature in 0.1° increments
  • Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . 15 to 35°C
  • Humidity restrictions. . . . . . . . . . . . . . . . . . . . . . . . <95% (noncondensing)
  • Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . below 10 microns (1.34 Pa)
  • Acceleration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 acceleration profiles—9 slow rates from 0 to 5 000 rpm followed by full acceleration to set speed; or maximum acceleration
  • Deceleration . . . . . . . . . . . . . . . . . 11 deceleration profiles—10 slow rates n from 5 000 to 0 rpm, including coasting to a stop without brake; or full dynamic braking from set speed
  • Dimensions
  • Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.7 cm (29 in.)
  • Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58.4 cm (23 in.)
  • Height. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58.4 cm (23 in.)
  • Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 kg (217 lb)
  • Ventilation clearances (sides and rear) . . . . . . . . . . . . . . . . 7.6 cm (3.0 in.)
  • Finishes
  • Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . coated polycarbonate
  • Top surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . urethane paint
  • Other surfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . general purpose paint
  • Electrical requirements
  • 100-V instrument . . . . . . . . . . . . . . . . . . . 90–110 VAC, 12 A, 50/60 Hz
  • 120-V instrument . . . . . . . . . . . . . . . . . . 100–130 VAC, 12 A, 50/60 Hz
  • 220/240-V instrument . . . . . . . . . . . . . . . . . 198–254 VAC, 6 A, 50 Hz
  • Maximum heat dissipation into room under
  • steady-state conditions . . . . . . . . . . . . . . . . . . . . . . 1750 Btu/hr (0.5 kW)
  • Noise level 0.91 m (3 ft) in front of centrifuge . . . . . . . . . . . . . . . . <60 dBa
  • Installation category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II

Pollution degree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Learn More
Beckman-Coulter-Optima-Max-130000-Benchtop-Centrifuge-24217
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 23960, 17971, 13182, 23203, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-23960
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Waters 2695 HPLC System

Waters 2695 HPLC System

Cambridge ID #: 24672

This can be purchase with a number of optional detectors.
Description - The Waters 2695 features a large, easy-to-use LCD interface. Scientists can take advantage of the quick autostart and optimize their methods with a simple push of a button. Manage up to 120 industry standard vials with the built in autosampler. This reliable tool is a common work-horse in most analytical and contract labs. Built to meet labs rigorous requirements or routine analysis, this robust instrument is easily found in Pharmaceutical, Food Safety, R&D, Chemistry, Environmental or Quality Control labs. Simplify how you collect data, built-in compliance and validation features. The Empower software is capable of automating method development, archiving methods and customizing data reports.

The components can be customized to your needs.

You can get the system with any of the detectors, as well as an optional Computer.

  • 996 PDA Detector
  • 2996  PDA Detector
  • 2998 PDA Detector
  • 2487 UV detector
  • 2489 UV Detector
  • 2475 FLD detector:
  • Waters 2410 Refractive Index Detector:
  • Computer Loaded with Empowers 2 Software
Learn More
Waters-2695-HPLC-System-24672
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1315B HPLC Diode Array Detector

Agilent 1200 Series - G1315B HPLC Diode Array Detector

Cambridge ID #: 24717

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1315B-HPLC-Diode-Array-Detector-24717
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping