Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Electronic Pipette Stand: 1-15 of 91

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Rainin E4 XLS Electronic Pipette Stand

Rainin E4 XLS Electronic Pipette Stand

Cambridge Scientific ID #'s: 20074, 20073

Features:

 

Electronic Pipettes rack

Learn More
Rainin-E4-XLS-Electronic-Pipette-Stand-20074
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
IKA ETS D4 Electronic Contact ThermometerImage Coming Soon

IKA ETS D4 Electronic Contact Thermometer

Cambridge ID #: 15830

This Electronic contact thermometer contains 3 patented operating modes of IKA, with optimized PID control, RESET function and includes a stainless steel sensor. It ensures perfect temperature control without overshooting the set temperature, even in the case of quick heating.

Specifications:

  • Temperature Range: -50 °C - 450 °C
  • Immersion Depth Max:200 mm
  • Dimensions: 82 x 83 x 22 mm
  • Weight: 2 kg
  • Permissible Ambient Temperature:0 - 60°C
  • DC Voltage:8 - 16 V
  • Current Consumption: 15 mA
Learn More
IKA-ETS-D4-Electronic-Contact-Thermometer-15830
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Eppendorf Easypet 3 Pipette

Eppendorf Easypet 3 Pipette

Cambridge ID #: 14143

Experience a new dimension of electronic pipetting with the Eppendorf Easypet® 3. The latest technological developments give you complete speed control with the utmost precision. The lightweight, well-balanced Easypet 3 has been designed considering all ergonomic findings to fit comfortably in your hand and matches its shape to allow for fatigue-free pipetting.


Specifications:

  • Capacity: 0.1 - 100 mL
  • Charge time: Less than 3 hours
  • Cordless Run Time: Dispense approx. 2,000 times with a 25 ml pipette

 

Learn More
Eppendorf-Easypet-3-Pipette-14143
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Eppendorf Research Plus Pipette

Eppendorf Research Plus Pipette

Cambridge Scientific ID #'s: 15671, 15673, 15672, 15674

Specifications:

  • Part# 3121000074
  • Single-channel
  • Fixed
  • 100 µL
  • Yellow
Learn More
Eppendorf-Research-Plus-Pipette-15671
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Various Single & Multi-Channel PipetteImage Coming Soon

Various Single & Multi-Channel Pipette

Cambridge ID #: 2603
  • Some with Stand
  • Learn More
    Various-Single-&-Multi-Channel-Pipette-2603
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Newport Optical Breadboard w/ stand Antivibration Table

    Newport Optical Breadboard w/ stand Antivibration Table

    Cambridge ID #: 20547

    Optical Breadboard Anti-Vibration Table with Stand. Various sizes available.

    Learn More
    Newport-Optical-Breadboard-w--stand-Antivibration-Table-20547
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Market Forge STM-E Stand Alone Autoclave

    Market Forge STM-E Stand Alone Autoclave

    Cambridge Scientific ID #'s: 16292, 8965, 20079, 18693

    Specifications:

    • Outside dimensions: 18 3/4" wide, 31" deep, & 27 5/8" high (476mm wide, 787mm deep, 702mm high)
    • Chamber dimensions: 16" dia & 26" deep (406mm & 660mm)
    • Trays: 2
    • Tray capacity: 12" x 20" x 4" (305mm x 508mm x 102mm)
    • Electrical requirements:
      • Unit is rated at 12KW at 236 volts & equipped for operation at:
      • 208-240 VAC, 3 wire, 1 Phase, 60 Hz
      • 208-240 VAC, 4 wire, 3 Phase, 60 Hz
      • 220 VAC, 1 Phase, 50 Hz
      • 220 VAC, 3 Phase, 50 Hz

    Standard Equipment will include:

    • Automatic temperature control
    • Thermometer - 180 - 300 F (82-149 C)
    • Safety Valve
    • 0-30 lb. steam gauge
    • 0-60 minute timer
    Learn More
    Market-Forge-STM-E-Stand-Alone-Autoclave-16292
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Market Forge STM-EL Stand Alone Autoclave

    Market Forge STM-EL Stand Alone Autoclave

    Cambridge Scientific ID #'s: 20860, 16291

    Specifications:

    • Outside dimensions: 18 3/4" wide, 31" deep, & 27 5/8" high (476mm wide, 787mm deep, 702mm high)
    • Chamber dimensions: 16" dia & 26" deep (406mm & 660mm)
    • Trays: 2 Tray capacity: 12" x 20" x 4" (305mm x 508mm x 102mm)
    • Electrical requirements:
      • Unit is rated at 12KW at 236 volts & equipped for operation at:
      • 208-240 VAC, 3 wire, 1 Phase, 60 Hz
      • 208-240 VAC, 4 wire, 3 Phase, 60 Hz
      • 220 VAC, 1 Phase, 50 Hz
      • 220 VAC, 3 Phase, 50 Hz

    Standard Equipment will include:

    • Automatic temperature control
    • Thermometer - 180 - 300 F (82-149 C)
    • Safety Valve
    • 0-30 lb. steam gauge
    • 0-60 minute timer
    Learn More
    Market-Forge-STM-EL-Stand-Alone-Autoclave-20860
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1100 Series - G1364A HPLC Fraction Collector

    Agilent 1100 Series - G1364A HPLC Fraction Collector

    Cambridge Scientific ID #'s: 16335, 17472, 17967

    Features:

     

    • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

    • For preparative scale applications

     

    Specifications:

    • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
    • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
    • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
    • Maximum tube volume: ca. 45 ml
    • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
    • Delay volumes [μl]:
      • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
      • Diverter valve: ~15
      • Diverter valve to needle: ~110
      • Needle: -~5
    • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
    • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
    • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
    • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
    • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
    • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1364B HPLC Fraction Collector

    Agilent 1100 Series - G1364B HPLC Fraction Collector

    Cambridge ID #: 18542

    Features:

     

    • G1364B Fraction Collector, preparative scale, designed for flow rates up to 100 ml / min. and for the use with vials, deep well plates and test tubes up to 100 mm height
    • For Preparative Scale Applications

     

    Specifications:

    • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
    • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
    • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
    • Maximum tube volume: ca. 45 ml
    • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
    • Delay volumes [μl]:
      • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
      • Diverter valve: ~15
      • Diverter valve to needle: ~110
      • Needle: -~5
    • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
    • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
    • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
    • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
    • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
    • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1364B-HPLC-Fraction-Collector-18542
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1364C HPLC Fraction Collector

    Agilent 1100 Series - G1364C HPLC Fraction Collector

    Cambridge Scientific ID #'s: 16028, 16350, 16188

    Features:

     

    • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
    • For analytical scale applications

     

    Specifications:

    • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
    • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
    • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
    • Maximum tube volume: ca. 45 ml
    • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
    • Delay volumes [μl]:
      • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
      • Diverter valve: ~15
      • Diverter valve to needle: ~110
      • Needle: -~5
    • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
    • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
    • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
    • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
    • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
    • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1364D HPLC Fraction Collector

    Agilent 1100 Series - G1364D HPLC Fraction Collector

    Cambridge ID #: 17700

    For Preparative Scale Applications

    Specifications:

    • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
    • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
    • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
    • Maximum tube volume: ca. 45 ml
    • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
    • Delay volumes [μl]:
      • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
      • Diverter valve: ~15
      • Diverter valve to needle: ~110
      • Needle: -~5
    • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
    • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
    • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
    • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
    • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
    • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Cambridge ID #: 11049

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Cambridge Scientific ID #'s: 17966, 16346, 17971, 13182, 16326

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17966
    By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
    Agilent 1100 Series - G1379A HPLC Degasser

    Agilent 1100 Series - G1379A HPLC Degasser

    Cambridge Scientific ID #'s: 17697, 15934, 16078, 18444, 16060, 16141, 16316, 16327

    Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

     

    Specifications:

    • Maximum flow rate:
      • 10 ml/min per channel
      • 5-10 ml/min per at reduced degassing performance
    • Number of channels: 4
    • Internal volume per channel: Typically 12 ml per channel
    • Materials in contact with solvent: PTFE, PEEK
    • pH range: 1 – 14
    • Analog output (AUX): For pressure monitoring, range 0 – 3 V

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1379A-HPLC-Degasser-17697
    By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping