We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Floor Low Speed Centrifuge: 136-150 of 905

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17966, 16346, 17971, 13182, 16326

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17966
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1376A HPLC Capillary Pump

Agilent 1100 Series - G1376A HPLC Capillary Pump

Cambridge Scientific ID #'s: 9564, 15081, 17698

Specifications:

  • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
  • Settable column flow Range:
    • – 20 µl/min
    • – 100 µl/min (with the extended flow range kit)
    • – 2.5 µl/min (with the electronic flow control bypassed)
  • Recommended column flow range:
    • – 20 µl/min
    • 10 – 100 µl/min (with extended flow range kit)
    • – 2.5 ml/min (with the electronic flow sensor bypassed)
  • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
  • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
  • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
  • Delay volume:
    • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
    • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
    • for flow rates up to 100 µl/min and electronic flow control active:
    • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
    • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
  • Pressure range: 20 to 400 bar (5880psi) system pressure
  • Compressibility Compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog output For pressure monitoring, 2 mV/bar, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
  • Housing: All materials recyclable
Learn More
Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 17697, 15934, 16078, 18444, 16060, 16141, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-17697
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1100 Series - G1946D LC/MS System

Agilent 1100 Series - G1946D LC/MS System

Cambridge Scientific ID #'s: 10994, 12804

Includes Installation and One year Service Contract

 

Includes:

  • G1946D LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional Front end HPLC

Specifications

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed:
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1946D-LC-MS-System-10994
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Franklin Electric 1101006419 Vacuum PumpImage Coming Soon

Franklin Electric 1101006419 Vacuum Pump

Cambridge ID #: 10963

Specifications:

  • 50/60 Hz
  • 1/2 hp
  • 115/230 V
  • 7.0/3.5 amps
  • Pumping speed 4 CFM
Learn More
Franklin-Electric-1101006419-Vacuum-Pump-10963
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Clay Adams 1105 Nutator

Clay Adams 1105 Nutator

Cambridge ID #: 17847

A benchtop platform nutator/rotator platform, designed for continuous gentle mixing of solution in vials, tubes, and cylinders. Designed to produce a unique processional motion for holding cells in suspension without forming foam or bubbles.

Specifications:

  • Surface Dimensions: 1 x 9.5 in
  • Speed:12 rpm
  • Power Requirements:120V, 50/60Hz
  • Weight: 1 lbs
Learn More
Clay-Adams-1105-Nutator-17847
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Illumina 11197831 Microplate ShakerImage Coming Soon

Illumina 11197831 Microplate Shaker

Cambridge ID #: 17627

Description:

The Illumina high speed microplate shaker has the ability to shake traditional or deep-well microplates, shakes up to 48 microplates at one time, and can operate up to 2500 rpm while holding deep-well blocks and small diameter test tubes.

Specifications:

  • Speed Range: 600 to 2500 rpm
  • Orbit: 3.6 mm (0.14")
  • Maximum Capacity: 48 microplates or up to 7 lb (3.2 kg)
  • Timer: 1 second to 160 hours
Learn More
Illumina-11197831-Microplate-Shaker-17627
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1130-2S Recirculating Waterbath

VWR 1130-2S Recirculating Waterbath

Cambridge ID #: 19071

Features:

 

Microprocessor controller with LED set-and-read at an attractive price makes this model an excellent overall value. The bright LED display is easy to read and continuously displays actual temperature. The set temperature is displayed at the touch of a button. The 2-speed pressure (simplex) pump is used for closed-loop applications

 

Specifications:

Capacity: 6 liters

  • Temperature Range: Ambient + 5°C to 150°C
  • 120V
  • 60Hz
  • Reservoir Capacity: 28 liters
  • Pressure Flow Rate: 2-speed (Simplex Pump), 7 or 15 liters/min.
  • Working Access,L x W x D 12-1/8 x 10-3/4 x 8 in. 30.8 x 26.4 x 20.3 cm



Learn More
VWR-1130-2S-Recirculating-Waterbath-19071
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Forma 1148 Biosafety CabinetImage Coming Soon

Forma 1148 Biosafety Cabinet

Cambridge ID #: 8124

Description:

Forma Class II, Type B2 Benchtop Models provide maximum personnel and product protection by maintaining ultra-clean laminar airflow and total exhaust of the entire work zone air. Total exhaust makes units ideal for work that generates non-explosive chemical vapors and gases. Type B2 units may be used for work with biosafety levels 1, 2, and 3 biological agents, carcinogens, anti-neoplastic drugs, and low level radioisotopes

Specifications:

  • Type: 4 Ft. Benchtop
  • Window: Sliding window of 0.25" (0.6cm) thick laminated safety glass
  • Work Area: 46.5" W x 25.3" H x 25.0" F-B (118.1 cm x 64.3 cm x 63.5 cm)
  • Exterior Dimensions: 50.5" W x 69.8" H x 35.6" F-B (128.3 cm x 177.3 cm x 90.4 cm)
  • Electrical: 115V, 60 Hz, 6.0 FLA
  • Motor: 1/3 HP
  • Breaker Requirements: 15 Amp
  • Exhaust Requirements: 712-821 CFM
  • Weight: 750 lbs. (340.2 kg)
Learn More
Forma-1148-Biosafety-Cabinet-8124
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 1152049S Hot Plate/Stirring Hot Plate

Fisher Scientific 1152049S Hot Plate/Stirring Hot Plate

Cambridge ID #: 18374

Features:

This basic stirring hotplate is built with a ceramic top plate design which reduces chances of breakage and is resistant to acids and alkalis. It is also designed to divert spills away from the internal components for product and user safety.

Specifications:

  • Controller Type: Knob
  • Speed: 2500 rpm
  • Voltage: 120V
  • Material: Ceramic
  • Surface Area: 7 x 7 in.
  • Temperature Range (English): 1000°F
  • Temperature Range (Metric): 538°C
  • Hertz: 60Hz
  • Electrical Requirements: 120V 60Hz
Learn More
Fisher-Scientific-1152049S-Hot-Plate-Stirring-Hot-Plate-18374
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 1152049SH Hot Plate/Stirring Hot PlateImage Coming Soon

Fisher Scientific 1152049SH Hot Plate/Stirring Hot Plate

Cambridge ID #: 18639

Specifications:

  • Speed: 2500 rpm
  • Temperature Range: 538°C
  • Material: Ceramic
  • Surface Area: 7 x 7 in.
  • Electrical Requirements: 120V 60Hz
  • Controller Type: Knob
Learn More
Fisher-Scientific-1152049SH-Hot-Plate-Stirring-Hot-Plate-18639
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1311A HPLC Quaternary Pump

Agilent 1200 Series - G1311A HPLC Quaternary Pump

Cambridge ID #: 20563

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-20563
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping