Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Incubators ranging from General purpose Incubators, C02 Incubators, C02 water-jacketed Incubators, Refrigerated Incubators, and Shaking Incubators to Environmental Incubators and Humidity Incubators. Some of our popular manufacturers include Fisher, VWR, Thermo Forma, Precision, Sanyo and Hereaus.

Fplc Controller: 46-60 of 160

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Fisher Scientific 1152049SH Hot Plate/Stirring Hot Plate

Fisher Scientific 1152049SH Hot Plate/Stirring Hot Plate

Cambridge ID #: 18639

Specifications:

  • Speed: 2500 rpm
  • Temperature Range: 538°C
  • Material: Ceramic
  • Surface Area: 7 x 7 in.
  • Electrical Requirements: 120V 60Hz
  • Controller Type: Knob
Learn More
Fisher-Scientific-1152049SH-Hot-Plate-Stirring-Hot-Plate-18639
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1162 Heated/ Refrigerated Circulator

VWR 1162 Heated/ Refrigerated Circulator

Cambridge ID #: 14888

Specifications:

 

  • Temperature range: –20 to 100°C (–4 to 212°F)
  • Cooling capacity: 200W at 20°C (68°F), 140W at 0°C (32°F), and 100W at –10°C (14°F
  • Capacity: 6 liters (1.6 gal)
  • Heater: 1000W
  • Analog Controller
Learn More
VWR-1162-Heated--Refrigerated-Circulator-14888
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment

Agilent 1200 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 24128, 23962

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment-24128
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 23961, 24073

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-23961
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1364C HPLC Fraction Collector

Agilent 1200 Series - G1364C HPLC Fraction Collector

Cambridge ID #: 23955

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1364C-HPLC-Fraction-Collector-23955
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge ID #: 24077

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-24077
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Cambridge ID #: 23958

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367C-HPLC-Well-Plate-Autosampler-23958
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1376A HPLC Capillary Pump

Agilent 1200 Series - G1376A HPLC Capillary Pump

Cambridge ID #: 20388

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1376A-HPLC-Capillary-Pump-20388
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative Autosampler

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1545 Incubator

VWR 1545 Incubator

Cambridge Scientific ID #'s: 23446, 24050, 11103, 15640

Heating elements in all three walls, bottom, and door create a warm air jacket around the inner chamber to guarantee superior temperature uniformity with no hot spots. Warm air jacket design also provides quick temperature recovery—and there’s a full-length inner glass door for viewing specimens without disturbing the chamber atmosphere. No need to worry about heater element damage from spills either—the inner chamber is tack-welded, and the low-watt density heating elements are safely isolated from the work chamber.

Microprocessor controlled for easy keypad set and calibration. Temperature display may be calibrated to match a secondary thermometer. For over-temperature protection, a second, independent safety controller can be preset and has visual alarm when activated. All units are stackable without the need for spacer racks. Features through-wall access port for chart recorder. A UL-approved, vapor-tight electrical outlet is inside the sealed chamber. Adjustable leveling feet compensate for uneven surfaces. Shelves adjustable in 1.3cm (1/2") increments.

 

Features:

  • Exclusive Hybrid Heating System
  • Microprocessor Control
  • Easy Keypad Set and Calibration
  • Over-Temperature Protection
  • Access Port
  • Heated Outer Door
  • Interior Electrical Outlet
  • Stainless Steel Interior and Shelves
  • Temperature Range: 5° above ambient to 60°C
  • Uniformity: ±0.25° at 37°C
Learn More
VWR-1545-Incubator-23446
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Bellco 1927 Roll-In Incubator

Bellco 1927 Roll-In Incubator

Cambridge ID #: 10153

The VWR Signature Reach-In Incubators are supplied with six shelves capable of supporting the weight of benchtop instruments. The air jacket design and heated outer door allows for uniform heat throughout the incubators. They incorporate a microprocessor controller to achieve precise temperature uniformity. An independent, secondary temperature controller offers the added security of over temperature protection. The chamber floors are reinforced to support roller apparatus or shakers.
Specifications:

 

  • Exterior Dimensions: 41 x 32 x 88 in
  • Interior Dimensions: 35 x 26 x 76 in
  • Power Requirements: 120V, 50/60Hz, 16A
  • Temperature Range: 5° above ambient to 70°C
  • Volume: 40 cubic feet

 

  • Carbon Dioxide Range: 0 - 20%
Learn More
Bellco-1927-Roll-In-Incubator-10153
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 1927 Reach In Incubator

VWR 1927 Reach In Incubator

Cambridge ID #: 13927

The VWR Signature Reach-In Incubators are supplied with six shelves capable of supporting the weight of benchtop instruments. The air jacket design and heated outer door allows for uniform heat throughout the incubators. They incorporate a microprocessor controller to achieve precise temperature uniformity. An independent, secondary temperature controller offers the added security of over temperature protection. The chamber floors are reinforced to support roller apparatus or shakers.
Specifications:

 

  • Exterior Dimensions: 41 x 32 x 88 in
  • Interior Dimensions: 35 x 26 x 76 in
  • Power Requirements: 120V, 50/60Hz, 16A
  • Temperature Range: 5° above ambient to 70°C
  • Volume: 40 cubic feet

 

  • Carbon Dioxide Range: 0 - 20%
Learn More
VWR-1927-Reach-In-Incubator-13927
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Flow Sciences 4720 Laminar Flow HoodImage Coming Soon

Flow Sciences 4720 Laminar Flow Hood

Cambridge ID #: 17222

Description:

An FS4700 series fan box consists of a motorized impeller installed in a housing with a variable speed controller. The housing is designed to fit over a HEPA filter on the inlet side and is equipped on the discharge side with a single outlet.

Learn More
Flow-Sciences-4720-Laminar-Flow-Hood-17222
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 625D Incubator

Fisher Scientific 625D Incubator

Cambridge Scientific ID #'s: 19021, 15648

 

Specifications:

  • Volume: 2.5 cu ft
  • Chamber Dimensions: 18 x 18 x 13.5 in
  • Case Material: Enamel coated Steel
  • Controller Type: Microprocessor
  • Temperature Range (Metric): 30 to 75°C
  • Material (Internal): Stainless Steel
  • Temperature Uniformity: ±0.7 at 37°C
  • Display: LED
  • Insulation: 3 in. Thick Fiberglass
  • Material: Steel
  • Resolution: 0.1°C

 

Description:

Incubators with gravity flow circulation provide accurate, efficient heating for routine laboratory procedures: drying and staining of slides, paraffin embedding, tissue culture work, incubation of antibody tests, microbiological determinations, crystallization studies and more. Electrical receptacle inside (5A at 120V) to plug in a stirrer, shaker or other apparatus.

Easy to operate

  • Microprocessor control
  • Controls are conveniently located at the top of the incubator chamber
  • Keypad with arrow keys to increase or decrease set point temperature in 0.1°C increments
  • Overtemperature value is automatically set at 3°C above setpoint
  • PID controller comes with fixed parameters so no tuning is required
  • Circuit breaker protects incubator from power surges; battery backup
  • Designed to stack two units

Big three-character LED display
  • Digits display actual temperature to nearest 0.1°C
  • Display shows current value for set point temperature
  • HEAT indicator light cycles on and off to show when incubator heaters are on
  • ALARM indicator lights up if temperature exceeds overtemperature limit; backup controller maintains temperature at 3°C above setpoint; safety backup built into software

Small, medium and large workload capacities
  • Available in three chamber capacities
  • Mounting holes at 2 in. (5cm) intervals on the chamber walls for shelf placement
  • Small incubator holds a maximum of five shelves, medium incubator holds eight, and large incubator holds eleven

Low-maintenance incubators with inner and outer doors
  • Cabinet has durable, enamel-coated steel exterior
  • Extruded aluminum trim has acrylic powder coating
  • Chamber is easy-to-clean stainless steel
  • Low-watt-density heater elements are designed for long life
  • Silicone gasket on outer door and 3 in. thick (7.6cm) fiberglass insulation throughout prevent heat loss
  • Outer door opens to 180° for unhindered access and features two grabber-type latches
  • Inner door is tempered glass
  • Steel shelves are 17.37 in. wide and 16.75 in. front-to-back (44 x 42.5cm)
  • Black synthetic rubber feet keep incubator from slipping and maintain a space between incubator and benchtop for ventilation
Learn More
Fisher-Scientific-625D-Incubator-19021
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Fisher Scientific 625F Forced Air Incubator

Fisher Scientific 625F Forced Air Incubator

Cambridge ID #: 15654

 

Specifications:

  • Temperature range: 5 to 75°C
  • Capacity: 2.2 cu ft, 62.6L
  • Material: Steel/aluminum
  • Interior Dimensions: 17 x 18 x 12.5 in.
  • Exterior Dimensions: 26 x 23.5 x 26 in.

 

Description:

  • With average temperature uniformity of ±0.3°C (±0.5°C absolute), these incubators operate within much tighter tolerances than gravity convection incubators.
  • Built-in PID microprocessor-based controller for close uniformity with set temperatures
  • Can set temperatures up to 75°C in 0.1°C increments using the keys on the control panel
  • Actual temperature is displayed (to the nearest 0.1°C) on the bright, three-digit LED display
  • If actual temperature exceeds setpoint by 3°C, a visual alarm will signal on the control panel
  • Tempered glass inner door to view samples
  • Temperature recovery is within two minutes
  • Heavy-duty steel/aluminum exterior; stainless-steel interior surrounded by 3 in. thick (7.6cm) insulation in the walls and 1.5 in. (3.8cm) in the door
  • 5-amp electrical outlet to support other apparatus
 
Learn More
Fisher-Scientific-625F-Forced-Air-Incubator-15654