Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Fplc Fraction Collector: 1-15 of 48

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Pharmacia FRAC-100 FPLC Fraction Collector

Pharmacia FRAC-100 FPLC Fraction Collector

Cambridge ID #: 17862

Description:

Pharmacia FRAC-100 Fraction Collector. Allows fractionation of FPLC material. Features peak detection/location capability, programmable collection modes, and communication with external components, tube and level sensors.

Specifications:

  • Tubing: 1.7-2 mm outer diameter
  • Time: 0.01-99.99 min (0.01 min increments), 100-999.9 min (0.1 min increments), 1 000-9 999 min (1 min increments) within an accuracy of ± 0.02%
  • Volume: 0.01-99.99 ml (0.01 ml increments), 100-999.9 ml (0.1 ml increments), 1 000-9 999 ml (1 ml increments) within and accuracy of ± 0.02%
  • Max Drop Rate: 15 drops/s
Learn More
Pharmacia-FRAC-100-FPLC-Fraction-Collector-17862
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE FRAC-900 FPLC Fraction Collector

Amersham Biosciences GE FRAC-900 FPLC Fraction Collector

Cambridge Scientific ID #'s: 7632, 6707, 5798

Features:

  • Frac-900 designed to work with AKTA series FPLC
  • 95 places rack for 10-18mm tubes
  • Fraction size 0.05 - 100 ml (0.001 ml increments)
  • Time mode 0.01-9.999min, volume mode 0.01-9.999 ml
  • Max flow rate 100 ml/min
  • Peak detection and location capability, programmable collection modes
Learn More
Amersham-Biosciences-GE-FRAC-900-FPLC-Fraction-Collector-7632
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Pharmacia FRAC-900 FPLC Fraction Collector

Pharmacia FRAC-900 FPLC Fraction Collector

Cambridge Scientific ID #'s: 16440, 8946

Features:

  • Frac-900 designed to work with AKTA series FPLC
  • 95 places rack for 10-18mm tubes
  • Fraction size 0.05 - 100 ml (0.001 ml increments)
  • Time mode 0.01-9.999min, volume mode 0.01-9.999 ml
  • Max flow rate 100 ml/min
  • Peak detection and location capability, programmable collection modes
Learn More
Pharmacia-FRAC-900-FPLC-Fraction-Collector-16440
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Amersham Biosciences GE Frac-950 FPLC Fraction Collector

Amersham Biosciences GE Frac-950 FPLC Fraction Collector

Cambridge Scientific ID #'s: 19075, 13340, 16288, 16150, 13653, 14492

Includes:

  • Manual
  • Vial Holder rack
  • Power Cord

 

Specifications:

  • Maximum flow rate: 100 ml/min
  • pH stability range: 1 to 13, 1 to 14 (<1 day exposure)

Fraction size

  • Volume mode: to 99999.99 ml
  • Time mode: to 99999.99 min

No spillage range for DropSync

  • Microplates: 0 to 1.0 ml/min
  • 12 mm rack: 0 to 1.5 ml/min
  • 18 and 30 mm rack: 0 to 2.0 ml/min

No spillage range for Accumulator

  • All racks: 0 to 100 ml/min
Learn More
Amersham-Biosciences-GE-Frac-950-FPLC-Fraction-Collector-19075
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Amersham Biosciences GE AKTA FPLC FPLC System

Amersham Biosciences GE AKTA FPLC FPLC System

Cambridge Scientific ID #'s: 16947, 16751

AKTA FPLC system is a fully automated liquid chromatography system designed for research scale purification of proteins, wherein proteins of various sizes can be readily purified using different kinds of columns.

 

Features:

  • P-920 Pump
  • UPC-900
  • Frac-900 Fraction Collector
  • INV-907 Injection Valve
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • Box 900: Storage compartment and Solvent Tray
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
  • Manuals
Learn More
Amersham-Biosciences-GE-AKTA-FPLC-FPLC-System-16947
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364B HPLC Fraction Collector

Agilent 1100 Series - G1364B HPLC Fraction Collector

Cambridge ID #: 18542

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364B-HPLC-Fraction-Collector-18542
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188, 15885

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad 2110 HPLC Fraction CollectorImage Coming Soon

Bio-Rad 2110 HPLC Fraction Collector

Cambridge Scientific ID #'s: 4737, 20471, 3465

The easy-to-use Model 2110 Fraction Collector provides multiple collection modes for chromatographic separations.

 

Features:

  • Time or drop collection modes (or volume collection mode when connected to the Model EP-1 Econo Pump, BioLogic LP System, or BioLogic DuoFlow System)
  • Collection of 1 drop (~50 µl) to 9 ml fractions in 80 test tubes or microtubes (with optional adaptor)
  • Small chromatography columns can be mounted to drop-forming arm to minimize dead volume
  • Manual-advance tube changes
  • Coldroom compatibility
  • Small footprint of 24 x 33 cm

Specifications:

  • Capacity: Eighty 13 x 100 mm glass, polypropylene, or polystyrene test tubes, or 1.5 ml microtubes when using optional micro tube adaptor
  • Collection basis: 1–999 drops in 1 drop increments, 0.05–9.99 min in 0.01 min increments, 10.0–99.9 min in 0.1 min increments
  • Construction: Case and carousel, polypropylene; front panel, hard-coated polycarbonate
  • Drop former: Silicone rubber
  • Waste outlet tube: Polyurethane
  • Operating temperature: 4–40°C
  • Safety: Meets IEC 61010 and CSA 22.2 certification
  • Dimensions (W x D x H): 24 x 33 x 25 cm
Learn More
Bio-Rad-2110-HPLC-Fraction-Collector-4737
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Gilson FC204 HPLC Fraction Collector

Gilson FC204 HPLC Fraction Collector

Cambridge ID #: 20237

Specification:

 

  • 3-way valve: Three-port, PTFE, 67 µL internal volume. 3,5 µL dead volume from the common port to the normally closed port, up to 20 mL/min with large bore needle OR Three-port, PTFE, 114 µL internal volume. 6 µL dead volume from the common port to the normally closed port, up to 200 mL/min with large bore needle.

 

  • Contact control

 

    • Contact closure inputs for start/advance and end/home
    • Event mark output
    • One programmable output for control of peripheral devices
  • Data acquisition: An input channel for analog-to-digital conversion; digital data is transmitted on the GSIOC
  • Detector input: ±100 mV full scale
  • Display: two lines of 24 alphanumeric characters; backlit LCD
  • Drop counting: Up to 9999 drops per fraction. Maximum rate: 20 drops per second

 

  • Environmental conditions

 

    • Indoor use only
    • Up to 2000 meters altitude
    • 5° - 40°C temperature range
    • 75 - 105 kPa air pressure
    • Pollution degree 1 or 2 in accordance with IEC 66
    • Maximum relative humidity 80% for temperatures up to 31°, decreasing linearly to 50% relative humidity at 40°C.
  • Event marker: 100 ms pulse (contact closure)
  • Maximum collection volume/tube: 32 mL (18 x 180 mm tube) or 25 mL (18 x 150 mm tube)
  • Maximum fractions: up to 768 fractions when configured with eight 96-well, 2 mL Whatman/Plyfiltronics microplates on a Code 17 rack
  • Multi-cycle operation: repetitive collection of each sample into same set of tubes or collection each sample into different set of tubes
  • Multiple column collection: simultaneous collection from up to 18 columns with installation of optimal multiple column adapter(s).
  • Number of racks: One Code 16 or 16D rack, one Code 17 rack, or up to four Code 20-Series racks (all racks must be same code)
  • Operating modes: Time, drop, peak + time, peak + drop, and manual

 

  • Peak detection

 

    • Adaptive slope algorithm that applies use-specified parameters to accommodate drifting baselines, negative peaks, and asymmetrical peaks or absolute threshold level that collects all peaks above specified millivolt value
    • Peak Parameters: peak height or level, in mV, and peak width at half-height, in minutes
    • Minimum peak height for fractionation: 0.1 mV full scale
    • Detector-collector delay: 0.01 minute increments
  • Physical space requirement: 47.9 x 46.4 x 33.0 cm (18.9 x 18.3 x 13.0 in.)

 

  • Power requirements

 

    • Frequency: 50 to 60 Hz
    • Voltage: 100 - 120V or 220 - 240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
    • Current rating: 0.5A for 100 - 120V or 0.25A for 220 - 240V
  • Programmable time units (min.): from 0.01 to 99.99 minutes per tube, with 0.01 minute limit of resolution
  • Software control: Via Gilson Serial Input/Output CHannel (GSIOC) or by contact closure
  • Time based programming: Up to ten collection windows and ten drain steps in any mode
  • Tube change time: 100-720ms. Center-to-center, depending on rack type
  • Weight: 10.9 kg (24 lbs)
Learn More
Gilson-FC204-HPLC-Fraction-Collector-20237
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Transgenomic FCW 200 Wave HPLC Fraction CollectorImage Coming Soon

Transgenomic FCW 200 Wave HPLC Fraction Collector

Cambridge ID #: 7376

Description:

The Transgenomic WAVE Fragment Collector Model FCW 200 enables fully automated purification of nucleic acids with the WAVE System. Nucleic acid samples collected by the FCW 200 meet high purity and sample concentration requirements for use in molecular genetic analyses and genomics. The dual plate FCW 200 enables fully automated fractionation and purification of ss- and dsDNA, RNA, and synthetic oligonucleotides with minimum sample loss and minimum cross contamination. The FCW 200 is controlled by both NAVIGATOR Software and WAVEMAKER Software enabling multiple modes for collection of nucleic acid fragments including: Minimum detection threshold above baseline with proprietary baseline drift compensation; Time/eluent volume window around peak retention time; Combined peak and threshold detection; Positive and/or negative slope detection; Combined slope and threshold detection; User-defined collection time windows.

Specifications:

  • Electrical: 85-264 V, 47-440 Hz, 300 W
  • Dimensions: 14” x 18” x 13”
Learn More
Transgenomic-FCW-200-Wave-HPLC-Fraction-Collector-7376
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu FRC-10A HPLC Fraction Collector

Shimadzu FRC-10A HPLC Fraction Collector

Cambridge ID #: 18619

A proprietary band function enables obtaining accurate fractions even when the peak elution time varies, by catching the target component according to variations in the chromatogram. If connected to workstation software, fractions can be simulated on screen to determine whether or not the fraction program is appropriate.

 

Details:

  • Small and Large Volume Collection Capacity
    • The FRC-10A collects both analytical and preparative fractions. The standard configuration has a 144 5mL vial capacity. The large volume kit can be added for large volume collection.
  • Precise Peltier Temperature Control
    • For automated collection of thermally-labile fractions, Peltier temperature control keeps temperatures stable within a 4-70º C range.
  • Simplified Graphical Parameter Entry
    • Set up fractionation parameters graphically from the SCL-10AVP System Controller. Eliminate the guesswork of determining slope and level values.
  • Fraction Collection Flexibility
    • Tailor the collection to your application requirements.  Choose from collection criteria such as volume, threshold, and peak purity. A precise peak division feature ensures high purity fractions. The FRC-10A automatically adjusts for retention time shifts, so that only the peak of interest is collected. Our slope-override capability enables continued collection, even when the detector signal is off-scale.

Specifications:

  • Drive System and Fraction Collection Methods: Arm-Movement X-Y System
  • Select either solenoid valve or direct through nozzle
  • Fraction Modes: Manual or programmed fraction collection by combining 14 types of parameters, such as slope, level, and band
  • Number of Fractions: 16 to 144
  • Collection Tubes: Glass: 3.5, 5, 20, 32, or 50 mL, or user supplied
  • Polypropylene: 4.5, 5, 25, or 50 mL, or user supplied
Learn More
Shimadzu-FRC-10A-HPLC-Fraction-Collector-18619
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Pharmacia LKB Frac-100 HPLC Fraction CollectorImage Coming Soon

Pharmacia LKB Frac-100 HPLC Fraction Collector

Cambridge ID #: 13443

FRAC-100 (with its drop counting accessory) can collect fractions in a variety of different ways, based either on time, volume or drop counting, controlled via simple programs specified by the operator. For example, you can choose to collect uniform fractions of a fixed time period.

Specifications:

  • Fraction Size Timing:01-99.99 min (0.01 min increments)
  • Fraction Size Timing: 100-999.9 min (0.1 min increments)
  • Fraction Size Timing: 1000-9 999 min (1 min increments) within an accuracy of ± 0.02%
  • Fraction Size Volume: 01-99.99 ml (0.01 ml increments)
  • Fraction Size Volume: 100-999.9 ml (0.1 ml increments)
  • Fraction Size Volume: 1000-9 999 ml (1 ml increments) within and accuracy of ± 0.02%
  • Maximum Drop Rate: 15 drops/sec
  • Weight: 5 kg
  • Dimensions: 30 x 29 x 39 cm
  • Environment: +4 to +40°C, 20-95% relative humidity
  • Environment: 84-106 kPa (840-1060 mbar) atmospheric pressure
  • Peak Memory: up to 11 peaks
  • Tubing:7 – 2 mm outer diameter
Learn More
Pharmacia-LKB-Frac-100-HPLC-Fraction-Collector-13443
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE A-900 FPLC Autosampler

Amersham Biosciences GE A-900 FPLC Autosampler

Cambridge ID #: 6705

Features:

  • Loop volume 5-1000µl
  • 96 vials 1.5 ml vial capacity
  • A-900 autosampler designed for use with AKTA
  • Syringes 100 - 1000 µl
  • Built-in compressor
Learn More
Amersham-Biosciences-GE-A-900-FPLC-Autosampler-6705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping