Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Fplc Uv Detector: 1-15 of 109

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Pharmacia Optical Unit UV-1 FPLC UV DetectorImage Coming Soon

Pharmacia Optical Unit UV-1 FPLC UV Detector

Cambridge ID #: 7927

Description:

Single Path Monitor UV-1 is a dual beam flow through UV absorptiometer for monitoring the UV absorption of a flowing liquid at 254nm, 280 nm, or 405 nm, comes with the UV-1 control unit, optical unit, one 280 nm wavelength filter and one 280 nm converter, and with a flow cell with optical path length of either 3 mm or 10 mm.

Learn More
Pharmacia-Optical-Unit-UV-1-FPLC-UV-Detector-7927
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity H Class PDA Detector UPLC PDA Detector

Waters Acquity H Class PDA Detector UPLC PDA Detector

Cambridge ID #: 24677
  • This Waters ACQUITY UPLC H-Class System is the only quaternary based liquid chromatographic system that was designed for TRUE UPLC PERFORMANCE without compromise. Whether you routinely develop new methods or you perform routine analysis and support large numbers of samples, the ACQUITY UPLC H-Class System can help you reach your laboratory"™s goals of decreasing the time to result, while increasing the depth and quality of the information about your samples.
  • Learn More
    Waters-Acquity-H-Class-PDA-Detector-UPLC-PDA-Detector-24677
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Amersham Biosciences GE A-900 FPLC Autosampler

    Amersham Biosciences GE A-900 FPLC Autosampler

    Cambridge ID #: 6705

    Features:

    • Loop volume 5-1000µl
    • 96 vials 1.5 ml vial capacity
    • A-900 autosampler designed for use with AKTA
    • Syringes 100 - 1000 µl
    • Built-in compressor
    Learn More
    Amersham-Biosciences-GE-A-900-FPLC-Autosampler-6705
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Amersham Biosciences GE AKTA Prime Plus FPLC System

    Amersham Biosciences GE AKTA Prime Plus FPLC System

    Cambridge ID #: 21454

    AKTAprime plus is a compact chromatography system designed for one-step purification of proteins at laboratory scale. AKTAprime plus offers significant advantages in terms of speed, capacity and fraction collection.  AKTA PRIME is available only as a complete system with the following built-in functions: Gradient Pump, Motorized 8-port buffer selection valve, motorized injection valve, monitor, fraction collector.

     

     

    Features:

    • Fraction collector
    • pH Electrode
    • UV Monitor
    • Computer loaded w/ Primeview Software, Monitor Keyboard & Mouse 
    C
    Learn More
    Amersham-Biosciences-GE-AKTA-Prime-Plus-FPLC-System-21454
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    GE Healthcare AKTA Prime Plus FPLC System

    GE Healthcare AKTA Prime Plus FPLC System

    Cambridge ID #: 21051

    AKTAprime plus is a compact chromatography system designed for one-step purification of proteins at laboratory scale. AKTAprime plus offers significant advantages in terms of speed, capacity and fraction collection.  AKTA PRIME is available only as a complete system with the following built-in functions: Gradient Pump, Motorized 8-port buffer selection valve, motorized injection valve, monitor, fraction collector.

     

     

    Features:

    • Fraction collector
    • pH Electrode
    • UV Monitor
    • Computer loaded w/ Primeview Software, Monitor Keyboard & Mouse 
    C
    Learn More
    GE-Healthcare-AKTA-Prime-Plus-FPLC-System-21051
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Amersham Biosciences GE AKTAxpress Single Module FPLC System

    Amersham Biosciences GE AKTAxpress Single Module FPLC System

    Cambridge ID #: 11554

     

    ÄKTAxpress Module

     

    ÄKTA xpress is a chromatography system designed for automated, multistep protein purification of both single and multiple samples.

    • Unattended purification: Built-in purification knowledge combines software, hardware, and prepacked columns to eliminate time-consuming manual tasks.
    • Highest possible purity: Optimized protocols with up to four steps will deliver tagged proteins of near 100% purity. Built-in cleaning procedures between MAb samples to minimize carry over
    • High productivity: Each module can purify up to four proteins. The modular design offers adaptability to meet increased throughput needs.
    • Yield : The system is capable of purifying target proteins in yields varying from 1 to 50+ mg.
    • Akta Express has a Small footprint: A compact design allows the system to occupy minimal space on the bench or in the cold room.

     

    ÄKTAxpress Module

    • Complete Packsize: 1 Piece
    • Application: Unattended multistep purification of tagged proteins and antibodies
    • Flow Rate: 0.1-65 ml/min
    • Operating Pressure Max.: 3 MPa (435 psi)
    • Tubing i.d. [Flow Path]: 1 mm
    • Single Wavelength Detection: Mercury lamp and 254 and 280 nm filters included. Optional filters for 313, 365, 405, 436 and 546 nm.
    • Multiple Wavelength Detection: No
    • Flow Cell Path Length: 2 mm
    • Multiple Sample Injection: Yes, up to 4 samples
    • Autosampler Injection: No
    • Automatic Buffer Preparation: No
    • Buffer Selection: 10 buffer inlets
    • Multi-Step Purification: Yes, up to 4 steps
    • Relative Humidity: 20%-95% (non condensing)
    • pH Stability Long Term: 2-12
    • pH Stability Short Term: 1-14
    • Viscosity: max 5 cP
    • Width: 250 mm
    • Height: 660 nm
    • Depth: 600 mm
    • Weight: 30 kg
    • Voltage: 100-120/220-240 VAC
    • Power Consumption: 120 VA
    • Protection Class: IP 20
    • Pump Type: Piston pump, metering type
    Learn More
    Amersham-Biosciences-GE-AKTAxpress-Single-Module-FPLC-System-11554
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Amersham Biosciences GE Frac-900 FPLC Fraction Collector

    Amersham Biosciences GE Frac-900 FPLC Fraction Collector

    Cambridge Scientific ID #'s: 21455, 5798

    Features:

    • Frac-900 designed to work with AKTA series FPLC
    • 95 places rack for 10-18mm tubes
    • Fraction size 0.05 - 100 ml (0.001 ml increments)
    • Time mode 0.01-9.999min, volume mode 0.01-9.999 ml
    • Max flow rate 100 ml/min
    • Peak detection and location capability, programmable collection modes
    Learn More
    Amersham-Biosciences-GE-Frac-900-FPLC-Fraction-Collector-21455
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Amersham Biosciences GE Frac-950 FPLC Fraction Collector

    Amersham Biosciences GE Frac-950 FPLC Fraction Collector

    Cambridge Scientific ID #'s: 19075, 13340, 21300, 21299, 16150, 13653

    Includes:

    • Manual
    • Vial Holder rack
    • Power Cord

     

    Specifications:

    • Maximum flow rate: 100 ml/min
    • pH stability range: 1 to 13, 1 to 14 (<1 day exposure)

    Fraction size

    • Volume mode: to 99999.99 ml
    • Time mode: to 99999.99 min

    No spillage range for DropSync

    • Microplates: 0 to 1.0 ml/min
    • 12 mm rack: 0 to 1.5 ml/min
    • 18 and 30 mm rack: 0 to 2.0 ml/min

    No spillage range for Accumulator

    • All racks: 0 to 100 ml/min
    Learn More
    Amersham-Biosciences-GE-Frac-950-FPLC-Fraction-Collector-19075
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Amersham Pharmacia Biotech Frac-950 FPLC Fraction Collector

    Amersham Pharmacia Biotech Frac-950 FPLC Fraction Collector

    Cambridge ID #: 21833

    Includes:

    • Manual
    • Vial Holder rack
    • Power Cord

     

    Specifications:

    • Maximum flow rate: 100 ml/min
    • pH stability range: 1 to 13, 1 to 14 (<1 day exposure)

    Fraction size

    • Volume mode: to 99999.99 ml
    • Time mode: to 99999.99 min

    No spillage range for DropSync

    • Microplates: 0 to 1.0 ml/min
    • 12 mm rack: 0 to 1.5 ml/min
    • 18 and 30 mm rack: 0 to 2.0 ml/min

    No spillage range for Accumulator

    • All racks: 0 to 100 ml/min
    Learn More
    Amersham-Pharmacia-Biotech-Frac-950-FPLC-Fraction-Collector-21833
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Pharmacia UV-1 FPLC ControllerImage Coming Soon

    Pharmacia UV-1 FPLC Controller

    Cambridge Scientific ID #'s: 11915, 11914, 11916

    Description:

    Single Path Monitor UV-1 is a dual beam flow through UV absorptiometer for monitoring the UV absorption of a flowing liquid at 254nm, 280 nm, or 405 nm, comes with the UV-1 control unit, optical unit, one 280 nm wavelength filter and one 280 nm converter, and with a flow cell with optical path length of either 3 mm or 10 mm.

    Learn More
    Pharmacia-UV-1-FPLC-Controller-11915
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

    Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

    Cambridge Scientific ID #'s: 16036, 18127, 19166, 21297

    Specification:

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Wavelength range: 190–600 nm
    • Short term noise (ASTM): ±0.75×10-5 AU at 254 nm
    • Drift: 3 × 10 -4 AU/hr at 254 nm
    • Linearity: 2 AU (5%) upper limit
    • Wavelength accuracy:
    • Band width: 5 nm typical
    • Flow cells:
      • Standard: 14-μl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
      • High pressure: 14-μl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
      • Micro: 1-μl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
      • Semimicro: 5-μl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
    • Control and data evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter
    • Housing: All materials recyclable.
    Learn More
    Agilent-1100-Series---G1314A-HPLC-Variable-Wavelength-Detector-16036
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Agilent 1100 Series - G1315A HPLC Diode Array Detector

    Agilent 1100 Series - G1315A HPLC Diode Array Detector

    Cambridge ID #: 19152

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19152
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters 2996 UPLC PDA DetectorImage Coming Soon

    Waters 2996 UPLC PDA Detector

    Cambridge ID #: 24675
    This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
    Learn More
    Waters-2996-UPLC-PDA-Detector-24675
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

    Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 26233, 22326

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Hewlett-Packard-1100-Series---G1315A-HPLC-Diode-Array-Detector-26233
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1100 Series - G1315B HPLC Diode Array Detector

    Agilent 1100 Series - G1315B HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 16038, 25375, 22469, 24755

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-16038
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping