Labconco 37200-00 Laminar Flow Hood

Labconco 37200-00 Laminar Flow Hood

Cambridge ID #: 19770

2 ft Purifier Vertical Clean Bench

Specifications:

  • Nominal downflow velocity of 45-65 fpm
  • Aerodynamic air foil
  • Supply HEPA filter, 99.99% efficient on particles 0.3 micron
  • ISO Class 5 air (formerly Class 100 per Federal Standard 209E)
  • Disposable prefilter
  • Variable speed built-in blower with motorized impeller and solid state control rated for 10 amps
  • Intrinsically-sound, negative pressure design
  • Minihelic pressure gauge
  • Air diffuser
  • UV-resistant, glacier white and gray, powder-coated aluminum and steel construction
  • UV-opaque and resistant 1/4" thick tempered safety glass sash and sides
  • Fluorescent lamp
  • Light and blower switches
  • 9.4" high sash opening
  • Ergonomic 10° angled and hinged sash that pivots upward, locks to a loading height of 20" and has wiping seals to promote ISO Class 5 conditions
  • Two utility ports with iris openings and plugs
  • ETL Listing (115 volt, 60 Hz models)

 

Learn More
Labconco-37200-00-Laminar-Flow-Hood-19770
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Flow Sciences 4720 Laminar Flow HoodImage Coming Soon

Flow Sciences 4720 Laminar Flow Hood

Cambridge ID #: 17222

Description:

An FS4700 series fan box consists of a motorized impeller installed in a housing with a variable speed controller. The housing is designed to fit over a HEPA filter on the inlet side and is equipped on the discharge side with a single outlet.

Learn More
Flow-Sciences-4720-Laminar-Flow-Hood-17222
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AirClean Systems AirClean 600 - AC632TLFC Laminar Flow Hood

AirClean Systems AirClean 600 - AC632TLFC Laminar Flow Hood

Cambridge ID #: 23284

Features:

Benchtop Orbital Shakers Model 416 provides the largest platforms for maximum capacity and a better value, a superior balancing mechanism for vibration free shaking, and durable components for long life.

  • Specifications: 

              Physical Dimensions

              Outside Dimensions:32”w x 30”h x 24”d 

              Inside Dimensions: 31”w x 20”h x 23”d 

              Weight, including filters:100 lbs

 

  • Airflow Characteristics

              Low Airflow Alarm:Audible/Visual 

              Volume of Filtered Air: 200 CFM

              Linear Face Velocity:50 FPM

 

  • Electrical 

              Voltage:110VAC 60 Hz or 230VAC50 Hz 

              Current: 1.4A / .7A 

              Power Consumption: 150W

              Mains Fluctuation: ±10%

 

  • Fuses

              Type: 3A 250V, Slow Blow 5 X 20

              Requirements: 1 (110V) / 2 (230V) 

 

  • Environmental 

              Usage: Indoor Use Only

              Altitude: Up to 2000m 

              Humidity: 80% Max up to 31°C Decreasing Linearly to 50% at 40°C 

              Installation Category: II 

              Pollution Degree:

 

  • Operation 

              Speed Selection: Variable Speed

 

  • Construction 

              Top Material: ABS

              Front Panel and Sides (3): Lexan™ Polycarbonate

              Base Material: Structural Polypropylene 

 

  • Prefilter 1 

              Type: ACFLFPRE 

              Weight: 8 oz. 

              Dimensions: 24”l x 12”w x 3”h

              Requirements: 1

 

  • Options 

              Cart w/ two 4” locking wheels: 32”l x 24”w x 34”h

Learn More
AirClean-Systems-AirClean-600---AC632TLFC-Laminar-Flow-Hood-23284
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Germfree BZ3-RX Laminar Flow Hood

Germfree BZ3-RX Laminar Flow Hood

Cambridge ID #: 4550

Features:

Purair® FLOW series laminar flow hoods are designed to protect the work surface, products and materials from particulate contamination. Room air passes through a HEPA filter then uniformly by laminar flow through the cabinet interior to protect the work from unfiltered air. The airflow is oriented to exhaust airborne particulate introduced by the user.

Specifications:

  • Filters: 36 x 36 x 6
  • Motor: 3/4 Hp, 1450 rpm , 7.7 Amp
    Double Motor # 7024-1351 (permanent split capacitor)
  • Capacitor: 7.5 MFD
  • Circuit breaker: 15 Amp
Learn More
Germfree-BZ3-RX-Laminar-Flow-Hood-4550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Baker EG-6252 Laminar Flow Hood

Baker EG-6252 Laminar Flow Hood

Cambridge Scientific ID #'s: 20828, 20827, 24341, 24133

The Baker EdgeGARD clean bench is ideal for IV admixture preparation, drug compounding, plant cell culture, media preparation, pharmaceutical procedures, electronic assembly, and limited experimental research.

Features:

  • Length: Six Feet
  • Class 100 cleanliness
  • Laminar air flow across work surface - 100 FPM
  • Console Style
  • Stainless Steel Interior
  • Fluorescent Light
  • High velocity return air slots for maximum product protection
  • HEPA filter captures 0.3 micrometer particulates - in good operating condition
  • Interior Dimensions: 70.5 x 22 x 34 1/8 inches

Caution:

A clean bench is not designed to protect personnel or the environment from potentially harmful agents. The adequacy of this product for the user's personal safety, as with any clean bench, should be determined by an industrial hygienist or safety officer

 

Learn More
Baker-EG-6252-Laminar-Flow-Hood-20828
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Nuaire NU-201-630 Laminar Flow HoodImage Coming Soon

Nuaire NU-201-630 Laminar Flow Hood

Cambridge ID #: 24027
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Nuaire-NU-201-630-Laminar-Flow-Hood-24027
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Universal Hood II Gel Documentation System

Bio-Rad Universal Hood II Gel Documentation System

Cambridge ID #: 22351

Features:

 

The Biorad Universal Hood II Gel Doc is an easy-to-use, high-performance system that captures images in real time, allowing you to more accurately position and focus on your sample. The Gel Doc system combines a compact darkroom, UV-transilluminator workstation, CCD camera, motorized zoom lens, and user-friendly Quantity One software to document and quantitate gels stained with ethidium bromide and other fluorophores. The iris, zoom, and focus of the lens can be manipulated either onscreen within Quantity One software or by the instrument control panel. With Biorad's intuitive software, images acquired with the Gel Doc can be rapidly optimized, annotated, analyzed, and printed.




Specifications:

 

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 25 x 26 cm
  • Excitation source: Trans UV 302, 254, 365 nm & White, Epi-White light
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: CCD
  • CCD resolution (H x V): 768 x 494 RS-170  752 x 582 CCIR
  • Pixel size in microns (H x V): 8.4 x 9.8
  • Filter holder: 2 positions (1 Emmision Filter, 1 Chemi)
  • Emission filters: 1 included (amber), 4 optional
  • Dynamic range: 1.8 Orders
  • Pixel density (gray levels): 8 bit (256 gray levels)
  • Dynamic flat fielding: No
Learn More
Bio-Rad-Universal-Hood-II-Gel-Documentation-System-22351
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Qiagen  QIAgility PCR / Thermal Cyclers

Qiagen QIAgility PCR / Thermal Cyclers

Cambridge ID #: 20576

Features:

The QIAgility is a compact benchtop instrument that enables rapid, high-precision setup of PCR experiments with ready-to-use software for ease and convenience. The software provides step-by-step guidance for worktable setup and automatic calculation of all mixes, eliminating the need to program pipetting steps. Just select the kit and cycler, define your targets and start the run. For added flexibility the QIAgility is operated via a laptop computer.

 

Specifications:

  • CommunicationsUSB and RS232

  • Conductive Filtered Tips50 µl and 200 µl Conductive Filtered Tips for liquid-level sensing

  • Consumables (supplied): 10 racks of 50 µl Conductive Filtered Tips (960); 10 racks of 200 µl Conductive Filtered Tips (960); 25 x 5 ml tubes; 100 x 0.2 µl PCR tubes; 3 Tip Disposal Boxes

  • Dimensions Height: 45 cm (18 in.), instrument lid closed; Height: 86 cm (34 in.), instrument lid open; Width: 54 cm (21 in.); Depth: 63 cm (25 in.), without cables

  • Electrical: 100–240 V AC, 250 VA, 50–60 Hz

  • HEPA filter: Preinstalled dual-cartridge 3M Air-Mate HEPA (High Efficiency Particulate Air) filter system provides positive pressure clean air within the closed hood.

  • Humidity: Operating humidity: 40–70%

  • Liquid-level sensing: Minimum detection volume (10 µl in 200 µl PCR tubes). Only functional in combination with QIAGEN Conductive Filtered Tips.

  • Notebook (supplied): QIAgility comes with a notebook computer for added flexibility.

  • Pipetting head: Single channel

  • Place of operation: For indoor use only

  • Pollution level: 2

  • Precision: CV <1%, 5–200 µl (dry-well transfer) CV <5%, 2–5 µl (wet-well transfer) CV <10%, 1 µl

  • Software: Supplied with unlimited user license. Free upgrades by Web download.

  • Table capacity: 6 x SBS positions (127.76 x 85.48 mm) for adapters and Tip Rack Holders 1 x Master Mix Block 1x Reagent Block

  • TemperatureOperating temperature, 15–30 °C (59–86°F)

  • Tip disposal: All used tips ejected externally — no waste accumulation on the worktable

  • Tip volume: 1–200 µl

Learn More
Qiagen-QIAgility-PCR---Thermal-Cyclers-20576
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge ID #: 16028

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1364C HPLC Fraction Collector

Agilent 1200 Series - G1364C HPLC Fraction Collector

Cambridge ID #: 23955

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1364C-HPLC-Fraction-Collector-23955
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
USA Scientific 2641-0016 Microcentrifuge

USA Scientific 2641-0016 Microcentrifuge

Cambridge ID #: 23816

Description:

Personal centrifuge reaches top speed quickly and is ideal for spinning fluid down from tube caps and walls. Small size saves space on the bench or under the hood. Operate with the on/off switch or by opening and closing the lid.

Specifications:

  • Dimmesions: 5 1/8" W x 5 7/8" D x 4 5/8" H
  • Electrical Requirements: 110 V
  • Speed: 6000 RPM
  • Rotors: 6-place rotor for 1.5 or 2.0 mL tubes and 16-place rotor for 0.2 mL tubes
Learn More
USA-Scientific-2641-0016-Microcentrifuge-23816
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Lonza 57040 FlashGel System

Lonza 57040 FlashGel System

Cambridge ID #: 20077

Features:

 

The FlashGel Camera captures data from the FlashGel System and say goodbye to darkrooms and UV light. Complete separation and documentation safely, at your bench, in minutes. This simple digital camera in an enclosed hood connects directly to your laptop or PC via USB cable.

 

Specifications:

 

 

  • 5 minute separation and recovery, See bands in as little as 2 minutes
  • Recover samples directly without UV light band excision or purification
  • Real-time separation and documentation
  • Watch band migration as it happens
  • Photograph gels at the bench without DNA damaging UV light
  • Outstanding sensitivity and resolution

 

 

Learn More
Lonza-57040-FlashGel-System-20077
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Life Technologies Attune NXT AFC2 w/ autosampler Flow Cytometer

Life Technologies Attune NXT AFC2 w/ autosampler Flow Cytometer

Cambridge ID #: 23866
  • The 2020 Attune NxT Flow Cytometer has expanded functionalities to drive your research forward. Designed and developed to remove common barriers associated with flow cytometry, the evolutionary capabilities of the Attune NxT Flow Cytometer offer adaptable optical configuration options so you can get the most out of your multicolor analysis.
  • New CytKick and CytKick Max autosampler"”more efficiency for high-throughput assays
  • New 21 CFR part 11 compliant software for regulated laboratories on Windows 10 operating system
  • Improved workflow for run protocol and instrument settings management
  • Fast flow
  • The innovative combination of acoustic focusing technology coupled with traditional hydrodynamic focusing results in acquisition speeds up to 10X faster than other flow cytometers. This technology reduces the time needed to obtain results.
  • True 35,000 event/sec (+10% coincidence rates)
  • Maximum electronic speed of 65,000 events/sec
  • Analyze small or limited samples faster than ever
  • Efficiently run traditionally long assays
  • The Attune NxT Flow Cytometer is ideal for immunophenotyping and signaling studies, cell cycle analysis, detection of rare events, stem cell analysis, cancer and apoptosis studies, microbiological assays, and more.
  • Fit for your lab today and in the future
  • The instrument"™s modular design provides the flexibility to meet future capability needs with a variety of upgrade options. Purchase what you need now and easily upgrade later. The small footprint of the instrument requires minimal bench space, even allowing use in a cell culture hood.
  • Flexibility"”1 to 4 lasers, 14 colors, and 16 parameters
  • Field upgradeable"”choose to add additional lasers when you decide
  • Customizable band pass filters for expanded fluorochrome choices
  • Tune into your data
  • The Attune NxT Flow Cytometer easily runs most samples including cardiomyocytes. The system is designed with a clog-resistant syringe-driven system to push the sample with a force of up to 75 psi.
  • Flexibility in sample concentrations and sample types
  • Elimination of time-consuming concentration steps with No-Wash, No-Lyse Filter Kit
  • Analysis of dilute samples, including CSF, stem cells, mouse bone marrow, mouse blood, and thin needle aspirates
  • Acquisition of a high volume of samples in minimal time
  • Learn More
    Life-Technologies-Attune-NXT-AFC2-w--autosampler-Flow-Cytometer-23866
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping