We offer an assortment of refurbished and used Microscopes ranging from Inverted Microscopes, Compound Microscopes, Fluorescence Microscopes, Stereo/Dissecting Microscopes, and Biological Microscopes to Polarizing Microscopes. Some of our popular manufacturers include Nikon, Olympus, Zeiss, and Leica. We also feature microscope cameras, objectives and stands. Additionally, we sell a wide selection of Scanning Electron Microscopes including Hitachi and JEOL. Browse our used microscopes below.

High Intensity Illuminator: 106-120 of 675

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
VWR 945302 Mini Vortexer Vortexer

VWR 945302 Mini Vortexer Vortexer

Cambridge ID #: 21256

Features:

The VWR 945302 Fixed Speed Mini Vortex Mixer Cat No. 12620-838 is designed for vigorously vortexing samples in a wide variety of applications. Use with flasks, beakers, tubes, and microwell plates the Fixed Speed Mini Vortex Mixer has the capability of high speed mixing of samples at 3200rpm.

Specifications:

  • Max speed: 3200 rpm
  • Dimensions: 4" W x 6" D x 4" H (12 x 17 x 12 cm)
  • Weight: 11 lbs (5 kg)
  • Electrical: 120V, 50/60Hz, 75W
Learn More
VWR-945302-Mini-Vortexer-Vortexer-21256
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 9454FIFSUS VortexerImage Coming Soon

Fisher Scientific 9454FIFSUS Vortexer

Cambridge ID #: 22094

Fixed speed vortex mixer starts mixing when the head is pressed down. Speed is fixed at full rpm to provide vigorous vortexing of samples.

  • Touch mode operation
  • Fixed high speed mixing
  • Mixer includes both cup head and 3 in. head with cover
  • Speed Range: 3200rpm
  • Orbit: 4.9mm
  • Controls: None
  • Overall Dimensions: 4.8L x 6.8W x 4.8 in.H (12.2 x 17.3 x 12.2cm)
Learn More
Fisher-Scientific-9454FIFSUS-Vortexer-22094
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 949030 Dry Bath Incubator

VWR 949030 Dry Bath Incubator

Cambridge ID #: 16899

This VWR dry bath/incubator is a multi-purpose unit ideal for incubation and activation of cultures, enzyme reactions, blood urea nitrogen determinations, immunoassays, melting/boiling points, and a variety of other laboratory procedures. These high wattage, constant-temperature block heaters are economical and versatile. Requires minimum bench space and features convenient front-mounted temperature adjustment knobs providing high and low temperature control. Accepts separate interchangeable modular blocks (can be purchased separately), which accommodate various sample enclosures such as vials, microplates, PCR strips, and a wide variety of tubes. Each block contains a thermometer well, and features close tube-and-block contact for maximum heat retention.

Specifications:

  • Temperature Range:5° above ambient to 150°C
  • Temperature Stability:±2°C
  • Temperature Uniformity: ±5°C
Learn More
VWR-949030-Dry-Bath-Incubator-16899
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
VWR 949035 Dry Bath Incubator

VWR 949035 Dry Bath Incubator

Cambridge Scientific ID #'s: 17132, 5432, 14719

Features:

This VWR dry bath/incubator is a multi-purpose unit ideal for incubation and activation of cultures, enzyme reactions, blood urea nitrogen determinations, immunoassays, melting/boiling points, and a variety of other laboratory procedures. These high wattage, constant-temperature block heaters are economical and versatile. Requires minimum bench space and features convenient front-mounted temperature adjustment knobs providing high and low temperature control. Accepts separate interchangeable modular blocks (can be purchased separately), which accommodate various sample enclosures such as vials, microplates, PCR strips, and a wide variety of tubes. Each block contains a thermometer well, and features close tube-and-block contact for maximum heat retention.

Specifications:

Temperature Range: 5° above ambient to 150°C

Temperature Stability: ±2°C

Temperature Uniformity: ±5°C

Learn More
VWR-949035-Dry-Bath-Incubator-17132
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Perkin Elmer 9600 PCR / Thermal CyclersImage Coming Soon

Perkin Elmer 9600 PCR / Thermal Cyclers

Cambridge ID #: 6302

Description:

  • Reproducibility Of Cycle Times
  • Uniformity Of PCR Yields For Samples
  • Thin-Walled MicroAmp Reaction Tubes Allowing Efficient Heat
  • Transfer and Improving Equilibration Times
  • High Speed of Heating and Cooling
  • Heated Cover Assuring That Tubes Fit Tightly In The Wells
  • Oil-Free Operation

Specifications:

  • Dimensions: 30.5 x 52 x 61 cm
  • Weight: 40.5 kg
  • Input: 120 VAC, 60 Hz
  • Display: 40 Character Blue Luminescent Display
  • Temperature Range: 4°C to 99.9°C
Learn More
Perkin-Elmer-9600-PCR---Thermal-Cyclers-6302
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21357

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21357
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3F *NEW* Atomic Absorption Spectrophotometer

Persee A3F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21355

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3F-*NEW*-Atomic-Absorption-Spectrophotometer-21355
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3G *NEW* Atomic Absorption Spectrophotometer

Persee A3G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21356

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3G-*NEW*-Atomic-Absorption-Spectrophotometer-21356
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21354

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21354
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21352

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21353

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990G-*NEW*-Atomic-Absorption-Spectrophotometer-21353
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity SQD 2 LC/MS System

Waters Acquity SQD 2 LC/MS System

Cambridge ID #: 15346

The Waters SQ Detector 2 is an advanced bench top single quadrupole mass detector designed for high performance LC/MS applications. With a wide range of ionization options including Atmospheric Pressure Photo Ionization (APPI) and the Atmospheric Solids Analysis Probe (ASAP), the SQ Detector is ideally suited to a wide range of qualitative and quantitative applications.  The system includes IntelliStart Technology, for automated system optimization and status monitoring, ensuring that the highest quality of data is routinely available to all levels of operators

 

Includes:

  • Waters SQ Detector 2 UPLC/MS Mass Spectrometer
  • Enhanced high performance single quadrupole mass spectrometer system
  • Roughing Pump
  • Windows 7 Computer loaded w/ Mass Lynx 4.1
  • Optional Acquity UPLC
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Performance Specifications:

  • Acquisition modes
    • Full scan MS
    • Selected Ion Recording (SIR)
  • Radar: An information rich acquisition approach that allows you to collect highly specific quantitative date for targer compounds while providing the ability to visualize all other components
  • Mass range: 2 to 3072 m/z
  • Scan speed: Up to 15,000 Da/s
  • Examples of achievable acquisition rates:
    • 15 scans per second (m/z 100 to 1000)
    • 30 scans per second (m/z 50 to 500)
  • Mass stability: Mass drift is < 0.1 Da over a 24 hour period
  • Linearity of response: The linearity of response relative to sample concentration for a specified compound is four orders of magnitude from the limit of detection
  • Polarity switching time: 20 ms to switch between positive and negative ion modes
  • EPCi mode switching time: 20ms to sqitch between ESI and APCI
  • SIR acquisition rate: Minimum dwell time of 3 ms per SIR channel; Minimim inter-channel delay of 3ms
  • Number of SIR channels: Up to 16,384 SIR channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 1024 SIR channels when operating in GLP/secure mode (32 functions, 32 channels per function).
  • Mass resolution: Automatically adjusted (Intellistart) to desired resolution.

 

Learn More
Waters-Acquity-SQD-2-LC-MS-System-15346
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus Adventurer Precision AX223 *NEW* Analytical Balance

Ohaus Adventurer Precision AX223 *NEW* Analytical Balance

Cambridge ID #: 17669

Features:

Striking the ideal balance between inventive features and functional, uncomplicated weighing capabilities, the OHAUS Adventurer incorporates all of the applications necessary for routine weighing and measurement activities. With a color touchscreen, GLP/GMP compliance capabilities, two USB ports, and much more, Adventurer is the most complete balance in its class.

 

Specifications:

  • Dimensions (H x L x W): (13.39 in x 13.93 in x 9.05 in)
  • Maximum Capacity: 220 g
  • Readability: 1 mg
  • Pan Size: 5.1 in
  • Internal Calibration: AutoCal - Automatic
  • Draftshield: Yes
  • Communication: RS232;  USB; USB Host
  • Display: High resolution full colour VGA touch display
  • Linearity ±: 0.002 g
  • Minimum Weight (USP), Typical: 2 g
  • Pan Construction: Stainless Steel
  • Repeatability (typical): 1 mg
  • Stabilization Time: 2 s
  • Tare Range: To capacity by subtraction
  • Units of Measurement: Gram;  Milligram;  Carat; Ounce;  Ounce Troy; Pound;  Pennyweight; Grain; Newton;  Momme; Mesghal; Hong Kong Tael;  Singapore Tael; Taiwan Tael; Tical;  Tola; Baht; Custom
  • Working Environment: 50°F - 85°F, 80%RH, non-condensing (10°C - 30°C, 80%RH, non-condensing)
Learn More
Ohaus-Adventurer-Precision-AX223-*NEW*-Analytical-Balance-17669
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus Adventurer Precision AX223/E *NEW* Analytical Balance

Ohaus Adventurer Precision AX223/E *NEW* Analytical Balance

Cambridge ID #: 17670

Features:

Striking the ideal balance between inventive features and functional, uncomplicated weighing capabilities, the OHAUS Adventurer incorporates all of the applications necessary for routine weighing and measurement activities. With a color touchscreen, GLP/GMP compliance capabilities, two USB ports, and much more, Adventurer is the most complete balance in its class.

 

Specifications:

  • Dimensions (H x L x W): (13.39 in x 13.93 in x 9.05 in)
  • Maximum Capacity: 220 g
  • Readability: 1 mg
  • Pan Size: 5.1 in
  • Draftshield: yes
  • Communication: RS232;  USB; USB Host
  • Display: High resolution full colour VGA touch display
  • Linearity ±: 0.002 g
  • Minimum Weight (USP), Typical: 2 g
  • Pan Construction: Stainless Steel
  • Repeatability (typical): 1 mg
  • Stabilization Time: 2 s
  • Tare Range: To capacity by subtraction
  • Units of Measurement: Gram;  Milligram;  Carat; Ounce;  Ounce Troy; Pound;  Pennyweight; Grain; Newton;  Momme; Mesghal; Hong Kong Tael;  Singapore Tael; Taiwan Tael; Tical;  Tola; Baht; Custom
  • Working Environment: 50°F - 85°F, 80%RH, non-condensing (10°C - 30°C, 80%RH, non-condensing)
Learn More
Ohaus-Adventurer-Precision-AX223-E-*NEW*-Analytical-Balance-17670
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Motic AE2000 Binocular *NEW* Inverted Phase Contrast Microscope

Motic AE2000 Binocular *NEW* Inverted Phase Contrast Microscope

Cambridge ID #: 17519

Features:

  • Motic’s new AE2000 Inverted Microscope is designed for routine live cell inspection with an easy and flexible set up, ideal for University, routine-clinical, and lab environments. The model’s main applications offer superior image quality when viewing cell cultures in microbiology, living organisms and tissue culture samples.

    The newly designed Binocular Ergo tubes with 360° swiveling “butterfly” design offers the most comfortable observation position, especially useful for prolonged sample viewing. The auto on/off function of the power supply extends the lifespan of the sample and light bulb and at the same time saves energy. Another added feature, a modular interchangeable illumination concept, allows for the easy transition from Halogen to LED to fulfill a wide-range of customer viewing expectations. The improved phase contrast quality of the model makes the instrument suitable for a greater range of applications that demand precision optics. The entire microscope including optical system is manufactured now completely Lead Free, following the International RoHS regulations.

  • Binocular head Siedentopf type 45° inclined, 360º swiveling
  • Widefield high eyepoint eyepieces N-WF 10X/20mm with diopter adjustment and rubber eyecups
  • Side facing quadruple nosepiece
  • CCIS Plan Achromatic objectives PL4X, LWD PL40X
  • CCIS Plan Achromatic Phase objectives PL Ph10X, LWD PL Ph20X
  • ELWD condenser N.A. 0.30
  • Phase slider Ph1, BF
  • Phase centering telescope
  • Plain stage with metal & glass stage inserts
  • Halogen illumination 6V/30W with intensity control and sleeping mode

 

Learn More
Motic-AE2000-Binocular-*NEW*-Inverted-Phase-Contrast-Microscope-17519
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping