Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Absorbance Detector: 1-15 of 216

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Precision Detectors PD2123 HPLC Absorbance Detector

Precision Detectors PD2123 HPLC Absorbance Detector

Cambridge ID #: 13616

Features:

 

PD2100 Series Detector



Learn More
Precision-Detectors-PD2123-HPLC-Absorbance-Detector-13616
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dynamax UV-DII HPLC Absorbance DetectorImage Coming Soon

Dynamax UV-DII HPLC Absorbance Detector

Cambridge Scientific ID #'s: 8169, 6959

Description:

The Dynamax UV-DII absorbance detector measures absorbance alternately at first and second wavelengths. When a measurement is made at one wavelength, a projection is made, based on past measurement, of the value of absorbance at the other wavelength. A ratio is taken of the measured value at one wavelength with the projected absorbance at the other wavelength

Specifications:

  • Power: 100V/120V/220V/240V
  • Hz: 50-60Hz
  • Fuse: 5ASB/100/120V, 1.25ASB/220/240V
Learn More
Dynamax-UV-DII-HPLC-Absorbance-Detector-8169
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters Acquity TUV Detector UPLC TUV Detector

Waters Acquity TUV Detector UPLC TUV Detector

Cambridge Scientific ID #'s: 12726, 15339, 15345

The ACQUITY UPLC TUV Detector is a tunable, dual wavelength ultraviolet/visible (UV/Vis) detector that offers optimal linearity, resolution, and sensitivity for UPLC/UV separations.  It features uniquely designed, patented, light-guiding flow cell technology, low-noise performance (6 μAU), and support for data rates up to 80 Hz.  The ACQUITY UPLC TUV Detector, coupled with our innovative ACQUITY UPLC Column chemistries and separations modules, leverages ultra-low dwell volume and low-noise, high-speed detection to bring productivity, sensitivity, and resolution that are unprecedented in HPLC techniques being used in the laboratory today.

 

Specifications:

  • Wavelength range: 190 to 700 nm
  • Wavelength accuracy: ±1 nm
  • Linearity range: Deviation at 2.5 AU ≤5%, propylparaben, at 257 nm
  • Baseline noise:6 x 10^-3 AU, at 230 nm, 10 mm shunt cell, 1.0 second filter time constant
  • Drift: ≤5.0 x 10^-4 AU/hour/°C at 230 nm
  • Sampling rate: Up to 80 points/s
  • Unattended operation: Leak sensors, full diagnostic data captured through console software
  • Light source: Prealigned, intelligent technology Deuterium lamp
  • Flow cell design: Light-guiding UPLC flow cell with intelligent chip technology
  • Path length: 10 mm (analytical flow cell)
  • Cell volume: 500 nL (analytical flow cell)
  • Pressure limit: 1000 psi (all flow cells)
  • Wetted materials: 316 stainless steel, fused silica, Teflon AF, PEEK (analytical flow cell)
  • Optical bandwidth: 5 nm
Learn More
Waters-Acquity-TUV-Detector-UPLC-TUV-Detector-12726
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Visible/Absorbance Reader

Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Visible/Absorbance Reader

Cambridge ID #: 18282

The SmartReader 96 comes complete with 4 popular filters: 405,450,492,630nm and twenty six additional filters are available separately to cover a full range from 340 to 750nm.  The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming. Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons.  Kinetic calculations can be performed by setting multiple readings. The SmartReader 96 is a convenient stand alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing.  A data port can be used for connecting a computer or basic printer.

 

Specification:

 

  • Control and Display: 7 inch touch screen (800 x 480 pixels)
  • Light Source: Quartz-halogen lamp 6V/10W
  • Wavelength Range: 340-750nm (405, 450, 492 and 630 nm filters included)
  • Half-Bandwidth of filter: 3~9nm
  • Readout Range: 0~4.000 Abs
  • Linearity (405nm): 0~2.000 Abs <+1% / 0~4.000 Abs <+2%
  • Precision: CV</= 0.2% (0-3) Abs ; CV</= 01.0% (3-4) Abs
  • Test Speed: <6 sec. for 96 well plate
  • Shaking: 3 modes - slow, medium, fast
  • User Interface: Integrated software and touch screen control
  • Storage: 200 programs; 100,000 test records
  • Ports: USB ports for PC, printer, mouse and flash drive
  • Dimensions: 295x440x225 mm (11.6 x 17 x 8.75 inches)
  • Weight: 10 kg
Learn More
Benchmark-Scientific-Accuris-SmartReader-96-MR9600-*NEW*-Microplate-Visible-Absorbance-Reader-18282
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Devices Emax Microplate Visible/Absorbance Reader

Molecular Devices Emax Microplate Visible/Absorbance Reader

Cambridge ID #: 9074

The EMax Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggering mean time between failure (MTBF) of 20,000 hours is achieved by 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts. No optical alignment needed during the lifetime of the instrument!

 

Includes:

  • Computer Loaded with SoftMax Pro 5.4.1
  • All Necessary Cables and Cords
  • Manuals

 

Features:

  • Extend uptime with an estimated 20,000 hour mean time between failures
  • Maximize assay signal-to-noise ratios through a unique optical system that directs all available light to each well
  • Achieve higher throughput with a 5 second microplate read time
  • Read up to 2 wavelengths in endpoint absorbance for 96-well plates
  • Mix samples in microplate wells by user-programmable Automix feature
  • Operate without an attached computer using the onboard microprocessor
  • Add assay flexibility with additional filters

 

General Specifications:

  • Dimensions (H x W x D):4 x 18.3 x 13.4 in.
  • Wavelength range: 400 - 750 nm
  • Photometric range:000 to 4.000 OD
  • Wavelength selection: Filters
  • Photometric resolution: 0.001 OD
  • Endpoint read time: 5 seconds
  • Temperature range: Ambient
Learn More
Molecular-Devices-Emax-Microplate-Visible-Absorbance-Reader-9074
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Spectronic Genesys 20 Spectrophotometer Visible/Absorbance Reader

Thermo Spectronic Genesys 20 Spectrophotometer Visible/Absorbance Reader

Cambridge Scientific ID #'s: 13375, 16872

Multiple purpose capabilities allow you to measure a wide range of analytes.

 

Features:

  • Compact footprint provides a space-saving, convenient system
  • Intuitive keyboard with integrated controls and LCD display
  • Routine measurements require just a few keystrokes
  • Direct measurement of routine absorbance or transmittance data
  • Concentration mode for single point standard or factor-based quantitative analysis
  • Bidirectional RS-232-C interface

 

Specifications

  • Optical System: Grating based, 1200 lines/mm
  • Spectral Bandwidth: <=8nm
  • Wavelength Range: 325 to 1100nm
  • Wavelength Accuracy: ±2.0nm
  • Wavelength: Readout: 20-character, 2-line LCD
  • Readout: Absorbance, %Transmittance, Concentration
  • Range:
    • -0.1 to +2.5A
    • 0 to 125%T
    • 0 to 1999C
  • Accuracy:
    • ±0.003A from 0 to 0.3A
    • ±1% from 0.3 to 2.5A
  • Noise (at 500nm): <=0.001A at 0A; ±0.004A at 2A
  • Drift: 0.003A/hour
  • Stray Radiant Energy: <=0.1%T at 340 and 400nm
  • Communication Ports
    • RS-232-C (serial)
    • Centronics-compatible (parallel)
  • Dimensions: 13L x 12W x 7 in.H (33 x 30 x 19cm)
  • Net Weight: 10 lb. (4.5kg)
Learn More
Thermo-Spectronic-Genesys-20-Spectrophotometer-Visible-Absorbance-Reader-13375
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Thermo Forma Multiskan Ascent 354 Microplate Visible/Absorbance Reader

Thermo Forma Multiskan Ascent 354 Microplate Visible/Absorbance Reader

Cambridge ID #: 12592

Includes:

  • All Manuals Software  and Power Cords
  • Computer – Monitor – Keyboard –Mouse

 

Specifications:

  • Wavelength range:  340-850 nm
  • Linearity (96-well):  0-4 Abs, +/-2%, 0-3 Abs, +/-2% 340-405nm and continuous mode
  • Linearity (384-well):  0-3 Abs, +/-2%
  • Read-out range: 0-6 Abs
  • Accuracy:  +/-1% or 0.003 Abs
  • Measurement time (96):  9 sec continuous mode/14 sec stepping mode
  • Measurement time (384):  14 sec continuous mode/42 sec stepping mode
  • Light source:  Tungsten halogen lamp
  • Detector:  Si photodetector
Learn More
Thermo-Forma-Multiskan-Ascent-354-Microplate-Visible-Absorbance-Reader-12592
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Tecan Sunrise Microplate Visible/Absorbance Reader

Tecan Sunrise Microplate Visible/Absorbance Reader

Cambridge Scientific ID #'s: 17012, 18580

Specifications:

  • Optical System: 12 measurement channels, 1 reference channel
  • Wavelength Range: 340 to 750nm
  • Wavelength selection: Interefence filters (slide of 4 filters) Bandwidth:10nm
  • Measurement Range: 340 to 399nm: 0 to 3.0 OD, 400 to 750 nm: 0 to 4.0 OD
  • Accuracy: 0.0 to 2.0 OD/492 nm
  • 4 Filter Optics
Learn More
Tecan-Sunrise-Microplate-Visible-Absorbance-Reader-17012
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Molecular Devices ThermoMax Microplate Visible/Absorbance Reader

Molecular Devices ThermoMax Microplate Visible/Absorbance Reader

Cambridge ID #: 14137

The ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. With various on-board features and capabilities, the ThermoMax is ideal for use in modern laboratories involved in many applications. The ThermoMax performs automatic mixing before a reading and between readings to ensure reliable and precise results. The Microsoft Windows-based software guarantees smooth operation as it includes single and dual wavelength read, kinetic readings, automix (shake), endpoints, blank patterns, as well as curve fits. The ThermoMax microplate reader provides thermal control and vertical shake, perfect for kinetic readings involving growth curves at 5 seconds per plate. The system can perform readings in a photometric analysis mode as well as kinetic analysis at user-configurable kinetic ranges and intervals, run on-board and temperature regulation diagnostics.

Features:

  • Wide photometric range
  • Temperature-regulated
  • Thermal control and vertical shake
  • Microsoft Windows-based software
  • Automatic mixing
  • Five-second read per plate
  • Photometric and kinetic analysis mode

Specifications:

  • Wavelength range:- 340-750 nm
  • Photometric range: 0.000-4.000 OD
  • Kinetic read time: 5 second minimum between readings.
  • Endpoint read time: 6 sec.
  • Modes: Single wavelength, Dual wavelength, Kinetics, Range, Blank pattern.
Learn More
Molecular-Devices-ThermoMax-Microplate-Visible-Absorbance-Reader-14137
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Devices Vmax Microplate Visible/Absorbance Reader

Molecular Devices Vmax Microplate Visible/Absorbance Reader

Cambridge Scientific ID #'s: 14792, 14793, 7546

Includes:

  • Computer Loaded with SoftMax Pro 5.4.1
  • All Necessary Cables and Cords
  • Manuals

 

Features

  • Extend uptime with an estimated 20,000 hour mean time between failure
  • Maximize assay signal-to-noise ratios through a unique optical system that directs all available light to each well
  • Achieve higher throughput with a 5 second microplate read time
  • Read up to 2 wavelengths in endpoint or kinetic absorbance for 96-well plates
  • Mix samples in microplate wells by user-programmable Automix feature
  • Operate without an attached computer using the onboard microprocessor
  • Add assay flexibility with additional filters

 

General Specifications

  • Dimensions (in.): 7.4 (h) x 18.3 (w) x 13.4 (d)
  • Weight: 22 lb (10 kg)
  • Power source: 90-250 VAC, 50/60 Hz
  • Performance Specifications
  • Wavelength Range: 400-750 nm
  • Photometric Range: 0.000 to 4.000 OD
  • Wavelength Selection: Filters
  • Photometric Resolution: 0.001 OD
  • Endpoint Read Time: 5 seconds
  • Minimum Kinetic Interval: 5 seconds
  • Temperature Range: Ambient
Learn More
Molecular-Devices-Vmax-Microplate-Visible-Absorbance-Reader-14792
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

Cambridge Scientific ID #'s: 16036, 10251, 10893, 18127, 19166

Specification:

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Wavelength range: 190–600 nm
  • Short term noise (ASTM): ±0.75×10-5 AU at 254 nm
  • Drift: 3 × 10 -4 AU/hr at 254 nm
  • Linearity: 2 AU (5%) upper limit
  • Wavelength accuracy:
  • Band width: 5 nm typical
  • Flow cells:
    • Standard: 14-μl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
    • High pressure: 14-μl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
    • Micro: 1-μl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
    • Semimicro: 5-μl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
  • Control and data evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter
  • Housing: All materials recyclable.
Learn More
Agilent-1100-Series---G1314A-HPLC-Variable-Wavelength-Detector-16036
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1315A HPLC Diode Array Detector

Agilent 1100 Series - G1315A HPLC Diode Array Detector

Cambridge Scientific ID #'s: 19153, 18569, 19152

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19153
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1315B HPLC Diode Array Detector

Agilent 1100 Series - G1315B HPLC Diode Array Detector

Cambridge Scientific ID #'s: 16038, 18442

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-16038
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 12471, 16041, 17969, 13408, 16314, 16001, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping