Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Absorbance Detector: 106-120 of 216

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System  LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System LC/MS/MS Q Trap System

Cambridge ID #: 14550

 Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap LC/MS/MS
  • Agilent 1200 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quat Pump
    • Agilent G1315D DAD (Diode Array Detector)
  • Solvent Tray
  • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-w--Agilent-1200-HPLC-System-LC-MS-MS-Q-Trap-System-14550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Compartment HPLC Column CompartmentImage Coming Soon

Waters Column Compartment HPLC Column Compartment

Cambridge ID #: 9245

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Compartment-HPLC-Column-Compartment-9245
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Heater Module. HPLC Column CompartmentImage Coming Soon

Waters Column Heater Module. HPLC Column Compartment

Cambridge ID #: 7394

Features:

The Waters CHM Column Heater Module features serial output cable and fluid ports.

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Heater-Module.-HPLC-Column-Compartment-7394
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Water Heater HPLC Column CompartmentImage Coming Soon

Waters Column Water Heater HPLC Column Compartment

Cambridge ID #: 8911

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Water-Heater-HPLC-Column-Compartment-8911
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 11220, 12890, 12872, 12869, 11959, 12661, 13515, 13511, 13518, 15896, 13516, 13517, 12867, 12868, 12873, 12660

The Leap technologies CTC PAL HTC Auto sampler for HPLCs offer Precise and Accurate sample Loading, high throughput, flexible analysis while taking up limited bench space.

 

Includes:

  • HTC PAL Autosampler (Width: 534mm Depth: 385mm Height: 648mm)
  • Temperature controlled sample storage 3 drawer
  • XYZ injector/Arm
  • LC Injection valve- 6 port
  • Wash station
  • Gameboy controller
  • Power Supply
  • Manual
Learn More
Leap-Technologies-CTC-Analytics-HPLC-Well-Plate-Autosampler-11220
By clicking below we can further assist you with your inquiry. Inquire 16 In Stock Worldwide Shipping
Shimadzu DGU-20A5 HPLC Degasser

Shimadzu DGU-20A5 HPLC Degasser

Cambridge ID #: 22322

Features:

  • <400 uL internal volume
  • Plugs into LC-20A/LC-30A series pump for power and control
  • New material (Systec AF) allows high gas permeability
  • Peak efficiency in under 1 minute
  • Additional channel provided for autosampler rinse solution
Learn More
Shimadzu-DGU-20A5-HPLC-Degasser-22322
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Gilson FC204 HPLC Fraction Collector

Gilson FC204 HPLC Fraction Collector

Cambridge Scientific ID #'s: 21036, 20237

Specification:

 

  • 3-way valve: Three-port, PTFE, 67 µL internal volume. 3,5 µL dead volume from the common port to the normally closed port, up to 20 mL/min with large bore needle OR Three-port, PTFE, 114 µL internal volume. 6 µL dead volume from the common port to the normally closed port, up to 200 mL/min with large bore needle.

 

  • Contact control

 

    • Contact closure inputs for start/advance and end/home
    • Event mark output
    • One programmable output for control of peripheral devices
  • Data acquisition: An input channel for analog-to-digital conversion; digital data is transmitted on the GSIOC
  • Detector input: ±100 mV full scale
  • Display: two lines of 24 alphanumeric characters; backlit LCD
  • Drop counting: Up to 9999 drops per fraction. Maximum rate: 20 drops per second

 

  • Environmental conditions

 

    • Indoor use only
    • Up to 2000 meters altitude
    • 5° - 40°C temperature range
    • 75 - 105 kPa air pressure
    • Pollution degree 1 or 2 in accordance with IEC 66
    • Maximum relative humidity 80% for temperatures up to 31°, decreasing linearly to 50% relative humidity at 40°C.
  • Event marker: 100 ms pulse (contact closure)
  • Maximum collection volume/tube: 32 mL (18 x 180 mm tube) or 25 mL (18 x 150 mm tube)
  • Maximum fractions: up to 768 fractions when configured with eight 96-well, 2 mL Whatman/Plyfiltronics microplates on a Code 17 rack
  • Multi-cycle operation: repetitive collection of each sample into same set of tubes or collection each sample into different set of tubes
  • Multiple column collection: simultaneous collection from up to 18 columns with installation of optimal multiple column adapter(s).
  • Number of racks: One Code 16 or 16D rack, one Code 17 rack, or up to four Code 20-Series racks (all racks must be same code)
  • Operating modes: Time, drop, peak + time, peak + drop, and manual

 

  • Peak detection

 

    • Adaptive slope algorithm that applies use-specified parameters to accommodate drifting baselines, negative peaks, and asymmetrical peaks or absolute threshold level that collects all peaks above specified millivolt value
    • Peak Parameters: peak height or level, in mV, and peak width at half-height, in minutes
    • Minimum peak height for fractionation: 0.1 mV full scale
    • Detector-collector delay: 0.01 minute increments
  • Physical space requirement: 47.9 x 46.4 x 33.0 cm (18.9 x 18.3 x 13.0 in.)

 

  • Power requirements

 

    • Frequency: 50 to 60 Hz
    • Voltage: 100 - 120V or 220 - 240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
    • Current rating: 0.5A for 100 - 120V or 0.25A for 220 - 240V
  • Programmable time units (min.): from 0.01 to 99.99 minutes per tube, with 0.01 minute limit of resolution
  • Software control: Via Gilson Serial Input/Output CHannel (GSIOC) or by contact closure
  • Time based programming: Up to ten collection windows and ten drain steps in any mode
  • Tube change time: 100-720ms. Center-to-center, depending on rack type
  • Weight: 10.9 kg (24 lbs)
Learn More
Gilson-FC204-HPLC-Fraction-Collector-21036
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Transgenomic FCW 200 Wave HPLC Fraction CollectorImage Coming Soon

Transgenomic FCW 200 Wave HPLC Fraction Collector

Cambridge ID #: 7376

Description:

The Transgenomic WAVE Fragment Collector Model FCW 200 enables fully automated purification of nucleic acids with the WAVE System. Nucleic acid samples collected by the FCW 200 meet high purity and sample concentration requirements for use in molecular genetic analyses and genomics. The dual plate FCW 200 enables fully automated fractionation and purification of ss- and dsDNA, RNA, and synthetic oligonucleotides with minimum sample loss and minimum cross contamination. The FCW 200 is controlled by both NAVIGATOR Software and WAVEMAKER Software enabling multiple modes for collection of nucleic acid fragments including: Minimum detection threshold above baseline with proprietary baseline drift compensation; Time/eluent volume window around peak retention time; Combined peak and threshold detection; Positive and/or negative slope detection; Combined slope and threshold detection; User-defined collection time windows.

Specifications:

  • Electrical: 85-264 V, 47-440 Hz, 300 W
  • Dimensions: 14” x 18” x 13”
Learn More
Transgenomic-FCW-200-Wave-HPLC-Fraction-Collector-7376
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex FLM-3300, NANO, 1X2P-10P HPLC Degasser

Dionex FLM-3300, NANO, 1X2P-10P HPLC Degasser

Cambridge ID #: 10565

Description:

The UltiMate 3000 Flow Manager FLM-3000 series features the UltiFlow eluent delivery system for nano, capillary, and micro flow rates. It integrates column thermostatting and includes up to two low-dispersion switching valves for automated sample preparation and multidimensional LC applications.

  • UltiFlow technology for nano, capillary, and micro flow rates (50 nL/min–160 µL/min)
  • Electronical nano, capillary and micro flow control for high retention time precision
  • Easy change of flow rate range (nano, cap, or micro) by exchanging the splitter cartridge
  • Column thermostatting from 5 to 70 ºC, (max. 15 ºC below ambient)
  • Short warm-up/cool-down times for fast temperature stabilization
  • Column capacity of up to three microcolumns (max length: 30 cm)
  • Thermostatted microswitching valves for maximum application flexibility
  • Biocompatible versions for delicate biomolecule analyses and high salt applications
  • Enables Proteomics MDLC solutions

Specifications:

  • Temperature Range: 5–70°C or 15°C below ambient
  • Temperature Accuracy: ±0.5°C
  • Temperature Stability and Precision: ±0.1°C
  • Heat-Up and Cool-Down Time: from 20°C to 50°C in less than 25 min, from 50°C to 20°C in less than 35 min
  • Switching Valves: two low-dispersion thermostatted 2-position 10-port micro valves
  • Column Capacity: up to three columns, max. 30 cm length
  • Flow Splitter/Control: thermostatted nano, capillary, or micro splitter with automatic identification system
  • Flow Range Selection: 50–1000 nL/min (nano), 0.5–10 µL/min (capillary), 10–160 µL/min (micro flow splitter)
  • Maximum Column Pressure: 35 MPa (4900 psi)
Learn More
Dionex-FLM-3300,-NANO,-1X2P-10P-HPLC-Degasser-10565
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu FRC-10A HPLC Fraction Collector

Shimadzu FRC-10A HPLC Fraction Collector

Cambridge ID #: 18619

A proprietary band function enables obtaining accurate fractions even when the peak elution time varies, by catching the target component according to variations in the chromatogram. If connected to workstation software, fractions can be simulated on screen to determine whether or not the fraction program is appropriate.

 

Details:

  • Small and Large Volume Collection Capacity
    • The FRC-10A collects both analytical and preparative fractions. The standard configuration has a 144 5mL vial capacity. The large volume kit can be added for large volume collection.
  • Precise Peltier Temperature Control
    • For automated collection of thermally-labile fractions, Peltier temperature control keeps temperatures stable within a 4-70º C range.
  • Simplified Graphical Parameter Entry
    • Set up fractionation parameters graphically from the SCL-10AVP System Controller. Eliminate the guesswork of determining slope and level values.
  • Fraction Collection Flexibility
    • Tailor the collection to your application requirements.  Choose from collection criteria such as volume, threshold, and peak purity. A precise peak division feature ensures high purity fractions. The FRC-10A automatically adjusts for retention time shifts, so that only the peak of interest is collected. Our slope-override capability enables continued collection, even when the detector signal is off-scale.

Specifications:

  • Drive System and Fraction Collection Methods: Arm-Movement X-Y System
  • Select either solenoid valve or direct through nozzle
  • Fraction Modes: Manual or programmed fraction collection by combining 14 types of parameters, such as slope, level, and band
  • Number of Fractions: 16 to 144
  • Collection Tubes: Glass: 3.5, 5, 20, 32, or 50 mL, or user supplied
  • Polypropylene: 4.5, 5, 25, or 50 mL, or user supplied
Learn More
Shimadzu-FRC-10A-HPLC-Fraction-Collector-18619
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 Honeycomb HPLC Fraction Collector

Honeycomb HPLC Fraction Collector

Cambridge Scientific ID #'s: 22446, 22447

The BAS HoneyComb™ is a refrigerated fraction collector designed to collect samples from microdialysis or ultrafiltration probes at low flow rates (normally 1-2 µL/min). It may also

be used to collect fractions eluting from a microbore chromatography column (aqueous mobile phase) at flow rates less than 200 µL/min. The HoneyComb is part of the BAS Bee

family of products for in vivo sampling, although hymenoptera are generally not among the animal subjects studied.

 

Features:

  • One or two sample cannulas
  • Sample vials refrigerated to 4 °C
  • Open architecture permits vial removal and replacement during collection
  • Uses sealed or open vials or combination
  • Loaded carousel may be removed and stored
  • Simple method setup via front panel keypad and LCD display
  • Remote control via Queen Bee Intelligent Syringe Pump or rear panel input
  • Optional method delay allows rest of system to equilibrate
  • Unit may be slaved to Pollen-8 OnLine Injector for collect/inject operation
  • Simple maintenance and replacement of sampling needle
  • Sampling needle has small internal volume (7.1 µL)
Learn More
-Honeycomb-HPLC-Fraction-Collector-22446
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Thermo Hot Pocket HPLC Column Compartment

Thermo Hot Pocket HPLC Column Compartment

Cambridge Scientific ID #'s: 12891, 12893, 12892

Thermo Scientific HOT POCKET Column Heater offers column heating in a compact, efficient design.

  • Easy to install and use with a variety of column lengths up to 300mm
  • Dual display of both actual and set point temperatures
  • Soft, wrap-around sealing mantle fits directly onto the column

 

Specifications:

  • Temperature range: Just above ambient to 85°C
  • Temperature accuracy: ±2°C with ±0.1°C stability
Learn More
Thermo-Hot-Pocket-HPLC-Column-Compartment-12891
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Persee L600 *NEW* HPLC Pump

Persee L600 *NEW* HPLC Pump

Cambridge ID #: 21340

Features:

  • Same specifications as popular HPLC
  • Excellent reliability and stability
  • Modular design enables flexible configurations
  • Automatic data save in the event of accidental power off
  • Optional UVD, DAD, FLD, RID and ELSD

Specifications:

Type Serial: dual plunger
Flow range: 
0.001-10.000 ml/min, 0.001 ml/min increment
Compressive compensation: 
User defined
Seal wash: 
Manual
Max pressure: 
40 Mpa/5800 psi
Pressure ripple: 
≤1 % (1 ml/min, degassed methol)
Flow precision: 
≤0.3 % RSD
Flow accuracy: 
1 %
Number of solvents and setting range: 
Isocratic, 0-100 %, 0.1 increments
Composition accuracy: 
≤2 %
Power requirements: 
95-240 V, 50/60 Hz, 150VA
Dimension: 
15.5 x 21.6 x 6.6 in
Weight: 
32 lb
Sound pressure level: 
<70dB

Learn More
Persee-L600-*NEW*-HPLC-Pump-21340
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu LC-20AT HPLC Pump

Shimadzu LC-20AT HPLC Pump

Cambridge Scientific ID #'s: 22321, 22320, 22318

The LC-20AT possesses a high level of stability while maintaining high performance during routine use. The ability to remove pulsations has been improved by modifying the pump-head structure and the flow line.

Features:

  • Enhanced Solvent Delivery Specifications: Flow-rate accuracy and precision in the micro-flow rate region have been improved with the addition of a new type of check valve and modifications to the solvent delivery control method. Non-polar organic solvents such as hexane can be delivered stably.
  • Improved Durability: New and improved plunger seal materials ensure robust, long-lasting performance. A sapphire plunger optimized according to its crystal structure and a precise plunger-holding mechanism help increase the service life of plunger seals and enable stable solvent delivery over long periods.
  • Space-saving Designs: An optional low pressure gradient valve (LC-20AD/20AT), CBM-20Alite system controller, and a seal wash pump (LC-20AD) can now be installed inside the solvent delivery unit, enabling 4-solvent gradient elution in a compact space. The LC-20AB high-pressure binary gradient pump delivers the performance of two LC-20AD pumps in one compact unit.

 

Specifications:

  • Solvent delivery method: Series-type double plunger
  • Plunger capacity: Primary side: 47µL, Secondary side: 23µL
  • Maximum discharge pressure: 40MPa
  • Flow-rate setting range: 0.001 to 10.000 mL/min.
  • Flow-rate accuracy: No more than 2% or 2µL/min., whichever is greater (0.01 to 5 mL/min.)
  • Flow-rate precision: No more than 0.06% RSD or 0.02 min SD, whichever is greater
  • Pulsation: 0.3 MPa (for water at 1.0 mL/min. and 7MPa)
  • Constant-pressure solvent delivery: Supported
  • Plunger rinsing mechanism: Manual rinsing or automatic rinsing using optional product
  • Safety measures: Liquid-leakage sensor, high-pressure/low-pressure limits
  • Operating temperature range: 4oC to 35oC
  • Dimensions, weight: 260 (W) x 140 (H) x 420 (D) mm, 11 kg
  • Power requirements: 100 VAC, 150 VA, 50/60 Hz 
  • Gradient type: High-pressure mixing
  • Number of mixed solvents: 2 or 3
  • Mixing concentration accuracy: 0.5% max. (LC-20AD), 1.0% max. (LC-20AT)
Learn More
Shimadzu-LC-20AT-HPLC-Pump-22321
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Pharmacia LCC-501 Plus HPLC Communication ModuleImage Coming Soon

Pharmacia LCC-501 Plus HPLC Communication Module

Cambridge ID #: 7933

Powerful multifunctional control unit for chromatography systems. Programmable memory allows control of chromatographic procedures, modifications of separation parameters, performance of multidimensional chromatography, as well as evaluation and print out of the chromatogram data.

Specifications:

 

  • Temperature Range: 4 to 40 °C
  • Memory capacity: 50 Methods
  • Dimensions: 16 L x 12 W x 4.7 H (in)

 

Learn More
Pharmacia-LCC-501-Plus-HPLC-Communication-Module-7933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping