Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Autosampler: 1-8 of 8

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Varian VK 7000 HPLC AutosamplerImage Coming Soon

Varian VK 7000 HPLC Autosampler

Cambridge ID #: 18436

The VK 7000 is designed with automation and flexibility in mind. These microprocessor-controlled instruments allow for easy manual sampling as well as direct interface with the VK 8000 Dissolution Sampling Station. The EaseAlign system for centering vessels allows the use of a variety of vessel sizes (with options of 100 mL, 200 mL, 1L (standard), and 2L and 4L vessels). These units are preconfigured to accept accessory upgrades. VK 7000 units can be fitted with a number of options including AutoTemp and Dosage Delivery capabilities. This model is easily adapted to interface directly to a variety of UV or LC systems.

 

Dimensions and Weight

 

  • Size (H x W x D): 37 x 26 x 22 in. (94 x 66 x 56 cm)
  • Weight: 155 lb / 70.3 kg
Learn More
Varian-VK-7000-HPLC-Autosampler-18436
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 WPS-3000TB HPLC AutosamplerImage Coming Soon

Dionex Ultimate 3000 WPS-3000TB HPLC Autosampler

Cambridge ID #: 17924

Specifications:

  • Sample capacity: Dependent on the carousel configuration: Vials/ Well plates
  • Injection methods: Inline split-loop
  • Injection volume settable range: 0.01 – 100 µL (1 – 100 µL)
  • Injection volume accuracy: Typically ±0.5% at 50 and 90 µL
  • Minimum sample required: 1 µL out of 5 µL (250 µL conical vial)
  • Injection cycle time: <15 seconds for 5 µL
Learn More
Dionex-Ultimate-3000-WPS-3000TB-HPLC-Autosampler-17924
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 WPS-3000TSL HPLC Autosampler

Dionex Ultimate 3000 WPS-3000TSL HPLC Autosampler

Cambridge Scientific ID #'s: 17919, 18419

Specifications:

  • Sample capacity: Dependent on the carousel configuration: Vials/ Well plates
  • Injection methods: Inline split-loop
  • Injection volume settable range: 0.01 – 100 µL (1 – 100 µL)
  • Injection volume accuracy: Typically ±0.5% at 50 and 90 µL
  • Minimum sample required: 1 µL out of 5 µL (250 µL conical vial)
  • Injection cycle time: <15 seconds for 5 µL
Learn More
Dionex-Ultimate-3000-WPS-3000TSL-HPLC-Autosampler-17919
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 15535, 15536, 15502, 15503, 17476, 17331, 16037, 15998

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-15535
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Dionex Ultimate 3000 WPS-3000T HPLC AutosamplerImage Coming Soon

Dionex Ultimate 3000 WPS-3000T HPLC Autosampler

Cambridge ID #: 15453

Specifications:

  • Sample capacity: Dependent on the carousel configuration: Vials/ Well plates
  • Injection methods: Inline split-loop
  • Injection volume settable range: 0.01 – 100 µL (1 – 100 µL)
  • Injection volume accuracy: Typically ±0.5% at 50 and 90 µL
  • Minimum sample required: 1 µL out of 5 µL (250 µL conical vial)
  • Injection cycle time: <15 seconds for 5 µL
Learn More
Dionex-Ultimate-3000-WPS-3000T-HPLC-Autosampler-15453
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge Scientific ID #'s: 9625, 9227, 15384, 7876, 18441, 16329, 15463, 16066, 15175, 16118

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-9625
By clicking below we can further assist you with your inquiry. Inquire 10 In Stock Worldwide Shipping
Agilent 1100 Series - G1389A HPLC Autosampler

Agilent 1100 Series - G1389A HPLC Autosampler

Cambridge Scientific ID #'s: 9301, 16033, 10407

Specifications:

  • Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
  • Settable injection volume
    • to 8 µl with small loop capillary
    • to 40 µl with extended loop capillary
  • Precision
    • Typically < 0.5 % RSD from 5 to 40 µl
    • Typically < 1 % RSD from 1 to 5 µl
    • Typically < 3 % RSD from 0.2 to 1 µl
  • Minimum sample volume: µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
  • Carryover
    • Typically < 0.1 % without automated needle wash
    • Typically < 0.05 % with external needle cleaning and 1 µl injection volume
  • Sample viscosity range: 2 - 5 cp
  • Recommended pH-range: - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
  • Material in contact with solvent: Stainless steel, sapphire, PTFE, PEEK, fused silica
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in aintenance areas, error detection and display
  • Housing: All material recyclable

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1389A-HPLC-Autosampler-9301
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Thermo Forma Accela Autosampler HPLC AutosamplerImage Coming Soon

Thermo Forma Accela Autosampler HPLC Autosampler

Cambridge ID #: 12670

Features:

  • Optimized for high-throughput applications and sub two micron column particles
  • Maximum reproducibility with isothermal injection and separation
  • Greater application flexibility with multiple sample formats
  • Superior robustness with a diamond coated high pressure valve Accela Photo Diode Array Detector
  • Highest detection sensitivity with proprietary LightPipe technology
  • Designed for U-HPLC separations with a 1cm path length, 2µL LightPipe flowcell
  • Maximum peak resolution with fiberoptic beam shaper
  • Easy maintenance with integrated wavelength validation

 

Specifications:

  • Sample capacity:
    • 200 vials in five removable trays
    • 288 samples in three 96-well microplates
    • 1152 samples in three 384-well microplates
  • Standard vial:8 mL volume
  • Injection precision: < 1.0% RSD at 5 μL and up
  • Partial loop injection volume:
    • 10 μL with standard 25 μL sample loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Fixed loop (full loop) injection volume:
    • 25 μL with standard loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Sample carryover:
    • < 0.1%
    • 6 mL flush volumes, user-specified for internal and external needle wash cycles
  • Minimum sample volume: 1 μL can be injected from 5 μL
  • Needle height control:
    • Programmable in 0.1 mm increments
    • Active vial bottom search selectable on/off
  • Column oven: Programmable in 1 °C increments from 5 to 95 °C
  • Tray temperature control:
    • Programmable in 1 °C increments from 0 to 60 °C
    • Typical vial temperature from 4 to 50 °C
  • Reagent vials: Four 16 mL vials can be specified for flush/wash or dilution functions
  • Remote inputs: Pump ready, inject hold
  • Remote outputs: Pump stop, autosampler ready, inject, gradient start, four timed events
  • Ambient environment:10 to 40 °C, 5 to 95% relative humidity, non-condensing
  • Power requirements: 100/120/220/240 Vac nominal; 50/60 Hz, 550 VA
Learn More
Thermo-Forma-Accela-Autosampler-HPLC-Autosampler-12670
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping