Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Autosampler Chiller / Thermostat: 1-15 of 200

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 22474, 14777, 15508, 15356, 15353, 17335, 16030, 15999, 15289

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22474
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 22471, 22466

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Hewlett-Packard-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22471
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 17699, 16315, 22332, 22112, 16338, 24125, 23205, 17972

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 21014, 22330, 23961, 23159, 24073

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-21014
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 20569, 20795

Features:

The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials

Specifications:

  • Temperature Range: Settable from 4 °C to 40 °C in 1 ° increments
  • Temperature Accuracy at Ambient
    • Temperatures < 25 °C and humidity < 50 %: 3 °C to 8 °C at a setpoint of 4 °C*
  • Temperature Accuracy at Ambient Temperatures
    • temperatures  < 30 °C and humidity < 60 %: 3 °C to 9 °C at a setpoint of 4 °C*
Learn More
Agilent-1290-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-20569
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Thermo Scientific Accela Autosampler HPLC Autosampler

Thermo Scientific Accela Autosampler HPLC Autosampler

Cambridge ID #: 12670

Features:

  • Optimized for high-throughput applications and sub two micron column particles
  • Maximum reproducibility with isothermal injection and separation
  • Greater application flexibility with multiple sample formats
  • Superior robustness with a diamond coated high pressure valve Accela Photo Diode Array Detector
  • Highest detection sensitivity with proprietary LightPipe technology
  • Designed for U-HPLC separations with a 1cm path length, 2µL LightPipe flowcell
  • Maximum peak resolution with fiberoptic beam shaper
  • Easy maintenance with integrated wavelength validation

 

Specifications:

  • Sample capacity:
    • 200 vials in five removable trays
    • 288 samples in three 96-well microplates
    • 1152 samples in three 384-well microplates
  • Standard vial:8 mL volume
  • Injection precision: < 1.0% RSD at 5 μL and up
  • Partial loop injection volume:
    • 10 μL with standard 25 μL sample loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Fixed loop (full loop) injection volume:
    • 25 μL with standard loop and 250 μL syringe
    • Up to 1000 μL injection volume with optional loops and syringes
  • Sample carryover:
    • < 0.1%
    • 6 mL flush volumes, user-specified for internal and external needle wash cycles
  • Minimum sample volume: 1 μL can be injected from 5 μL
  • Needle height control:
    • Programmable in 0.1 mm increments
    • Active vial bottom search selectable on/off
  • Column oven: Programmable in 1 °C increments from 5 to 95 °C
  • Tray temperature control:
    • Programmable in 1 °C increments from 0 to 60 °C
    • Typical vial temperature from 4 to 50 °C
  • Reagent vials: Four 16 mL vials can be specified for flush/wash or dilution functions
  • Remote inputs: Pump ready, inject hold
  • Remote outputs: Pump stop, autosampler ready, inject, gradient start, four timed events
  • Ambient environment:10 to 40 °C, 5 to 95% relative humidity, non-condensing
  • Power requirements: 100/120/220/240 Vac nominal; 50/60 Hz, 550 VA
Learn More
Thermo-Scientific-Accela-Autosampler-HPLC-Autosampler-12670
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Eppendorf ThermoStat C *NEW* Thermomixer

Eppendorf ThermoStat C *NEW* Thermomixer

Cambridge ID #: 17420

Features:


The ideal device to accurately set and maintain temperatures: The Eppendorf ThermoStat C is for heating and cooling almost any of your lab vessels.


Specifications:


Dimensions (W x D x H): 20.6 x 30.4 x 13.6 cm
Temperature range: Min: 30 °C below RT, max: 110 °C
Temperature accuracy: Max. ±0.5 °C at 20 – 45 °C
Temperature settings: -10 °C/110 °C
Heating rate: Max. 9 °C/min
Cooling rate: Max. 5.0 °C/min between 110 °C and RT
Timer: 15 s – 99.30 h, continuous
Power supply: 100 - 130 V, 50 - 60 Hz

Learn More
Eppendorf-ThermoStat-C-*NEW*-Thermomixer-17420
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma C35P Recirculating Chiller

Thermo Forma C35P Recirculating Chiller

Cambridge ID #: 13346

Specifications:

  • Temperature: 30° to 200°C
  • Temperature Accuracy: 0.01 +/-K
  • Capacity: 8L
Learn More
Thermo-Forma-C35P-Recirculating-Chiller-13346
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Neslab HX-150 Recirculating Chiller

Neslab HX-150 Recirculating Chiller

Cambridge ID #: 18447

Specification

 

  • Refrigerant: R22
  • Amount: 28 oz (794 g)
  • Hot gas settings: 25 PSIG (172 kPa)

 

  • Suction pressure at 25°C

 

    • Suction PSIG: 76 - 89
    • Discharge PSIG: 255 - 285
    • Speed check: 1.9 - 2.4
  • Temperature range: 5°C to 35°C
  • Cooling capacity at 20°C: 4500 Watts
  • Available voltage: 200 - 230V 1 Ph
  • Cooling options: Air / Water
Learn More
Neslab-HX-150-Recirculating-Chiller-18447
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Neslab Merlin M33 Recirculating Chiller

Thermo Neslab Merlin M33 Recirculating Chiller

Cambridge ID #: 19906

 

Specifications:

  • Capacity: 1.9L
  • Temperature Range: +5°C to +35°C
  • Temperature Stability:  ±0.1°C
  • Cooling Capacity at 20°C: 1250W
  • Cooling Capacity at 5°C: 490 W
  • Maximum Flow Rate (L/min): 6.75
  • Power Requirements: 115V, 60hz, 13A
Learn More
Thermo-Neslab-Merlin-M33-Recirculating-Chiller-19906
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 minichiller Chiller

minichiller Chiller

Cambridge ID #: 21998
  • Model: Minichiller
  • Order No: B02010003
  • Description: Water Cooler
  • Operating Temperature Range: -20...40-Degrees Centigrade
  • Display: Digital
  • Refrigeration Machine: Air Cooled, Natural Refrigerant
  • Refrigerant Type: R290
  • Refrigerant Quantity: 0.04 kg
  • Power Requirements: 115VAC 60Hz 4.0A
  • Learn More
    -minichiller-Chiller-21998
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
     RC006G03CB1C005 Recirculating Chiller

    RC006G03CB1C005 Recirculating Chiller

    Cambridge ID #: 22233
  • Recirculating Chillers with Cooling Capacities cools the synrad laser Specifications:- BTU/Hour: 11800; Amperage At 208/230 Volts AC: 16.0; Pump Type: Positive Displacement Pump"“Brass 4.3 gpm; Reservoir Capacity: 6; Recommended Cooling Fluids: Water or Ethlyene Glycol/Water Mixture; Phase: 1; Frequency Hz: 60Hz; Compressor Capacity Horse Power: 1.000; Dimensions (H x W x D): 31.9 x 21.4 x 27.8 in; Inlet Size: 1/2 FNPT; Outlet Size: 1/2 FNPT; Temperature Range 40 "“ 95; Tank Material: Polyethylene
  • Learn More
    -RC006G03CB1C005-Recirculating-Chiller-22233
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Lauda WK 1200 Recirculating Chiller

    Lauda WK 1200 Recirculating Chiller

    Cambridge ID #: 21271

    Features:

    •  Brinkmann Lauda WK 1200 Circulation Chiller 

    Specifications:

    • Working temperature range (°C): 0-40
    • Temperature stability (±K): 0.5
    • Cooling output at 20 °C: 1.2kW
    • Pump pressure max.: 3.2 bar
    • Pump flow max.: 40 L/min

     

    Learn More
    Lauda-WK-1200-Recirculating-Chiller-21271
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1313A HPLC Autosampler

    Agilent 1100 Series - G1313A HPLC Autosampler

    Cambridge ID #: 16066

    Specifications:

    • Injection range: From 0.1 – 100 µl in 0.1 µl increments
    • Replicate injections: From 1 – 99 from one vial
    • Injection cycle time: Typically 50 s, depending on draw speed and volume
    • Sample capacity: 100 × 2 ml vials in tray
    Learn More
    Agilent-1100-Series---G1313A-HPLC-Autosampler-16066
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1329A HPLC Autosampler

    Agilent 1100 Series - G1329A HPLC Autosampler

    Cambridge Scientific ID #'s: 23206, 19935, 17476, 17331, 16037

    Specifications:

    • Autosampler (Chiller Compatible)
    • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
    • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
    • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
    • Replicate injections: 1– 99 from one vial
    • Precision:
      • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
      • Typically < 1 % RSD of peak areas from 1 – 5 µl
    • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
    • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
    • Sample viscosity range: 2 – 50 cp
    • Replicate injections per vial: 1 – 99
    • Sample capacity:
      • 100 × 2-ml vials in 1 tray
      • 40 × 2-ml vials in ½ tray
      • 15 × 6-ml vials in ½ tray (Agilent vials only)
    • Injection cycle time: Typically 50 s depending on draw speed and injection volume

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1329A-HPLC-Autosampler-23206
    By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping