Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Column Compartment: 1-15 of 172

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Waters Column Compartment HPLC Column CompartmentImage Coming Soon

Waters Column Compartment HPLC Column Compartment

Cambridge ID #: 9245

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Compartment-HPLC-Column-Compartment-9245
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Heater Module. HPLC Column CompartmentImage Coming Soon

Waters Column Heater Module. HPLC Column Compartment

Cambridge ID #: 7394

Features:

The Waters CHM Column Heater Module features serial output cable and fluid ports.

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Heater-Module.-HPLC-Column-Compartment-7394
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Water Heater HPLC Column CompartmentImage Coming Soon

Waters Column Water Heater HPLC Column Compartment

Cambridge ID #: 8911

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Water-Heater-HPLC-Column-Compartment-8911
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment

Agilent 1100 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 14782, 14774, 13993, 14783, 15133, 17963, 13800, 19167, 14767

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment-14782
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1316D HPLC Column Compartment

Agilent 1100 Series - G1316D HPLC Column Compartment

Cambridge ID #: 17701

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316D-HPLC-Column-Compartment-17701
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment

Agilent 1200 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 21814, 21810, 19934

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment-21814
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G1316A HPLC Column Compartment

Agilent 1260 Infinity Series- G1316A HPLC Column Compartment

Cambridge ID #: 19977

Features:
The Agilent 1260 Infinity Thermostatted Column Compartment provides stable column cooling and heating up to 80 °C for standard applications. It fits neatly in a single stack of 1260 Infinity modules for lowest bench space requirements. An optional 2-position/6-port switching valve is available for 600 bar operation. For more sophisticated applications the Agilent 1290 Infinity Thermostatted Column Compartment is available, which fits seamlessly into any 1260 Infinity system.

Specifications:
Peltier cooling and heating for maximum temperature stability and application flexibility.
Spacious column racks hold up to three full-length, 30 cm columns.
Optional 2-position/6-port switching valve for 600 bar operation.
Simultaneous column identification of two columns for faster operation and reduced laboratory costs.
Independent heat exchangers with settable values facilitate two different temperature zones.
Low internal volume contribution of just 9 µL for low dispersion.

Learn More
Agilent-1260-Infinity-Series--G1316A-HPLC-Column-Compartment-19977
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G1316C HPLC Column Compartment

Agilent 1290 Series - G1316C HPLC Column Compartment

Cambridge Scientific ID #'s: 20567, 20797

Features:

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range: 10 degrees below ambient to 100 °C up to 80 °C: flow rates up to 5 ml/min up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability:  ± 0.05 °C
  • Temperature accuracy: ± 0.8 °C ± 0.5 °C With calibration
  • Column capacity: Three 30 cm
  • Warm-up/cool-down time: 5 min from ambient to 40 °C 10 min from 40 – 20 °C
  • Dead volume: 1.6 µl low dispersion heat exchanger 3 µl left heat exchanger 6 µl right heat exchanger
Learn More
Agilent-1290-Series---G1316C-HPLC-Column-Compartment-20567
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1290 Series - K1316C HPLC Column Compartment

Agilent 1290 Series - K1316C HPLC Column Compartment

Cambridge ID #: 20039

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---K1316C-HPLC-Column-Compartment-20039
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Hot Pocket HPLC Column Compartment

Thermo Hot Pocket HPLC Column Compartment

Cambridge Scientific ID #'s: 12891, 12893, 12892

Thermo Scientific HOT POCKET Column Heater offers column heating in a compact, efficient design.

  • Easy to install and use with a variety of column lengths up to 300mm
  • Dual display of both actual and set point temperatures
  • Soft, wrap-around sealing mantle fits directly onto the column

 

Specifications:

  • Temperature range: Just above ambient to 85°C
  • Temperature accuracy: ±2°C with ±0.1°C stability
Learn More
Thermo-Hot-Pocket-HPLC-Column-Compartment-12891
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Waters TCM HPLC Column CompartmentImage Coming Soon

Waters TCM HPLC Column Compartment

Cambridge ID #: 7445

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-TCM-HPLC-Column-Compartment-7445
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Temperature Control Module II HPLC Column CompartmentImage Coming Soon

Waters Temperature Control Module II HPLC Column Compartment

Cambridge ID #: 7396

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Temperature-Control-Module-II-HPLC-Column-Compartment-7396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment

Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment

Cambridge ID #: 17923

Specifications:

  • Temperature range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature accuracy: ±0.5 °C
  • Temperature stability: ±0.1 °C Temperature precision: ±0.1 °C
  • Column capacity: Up to 6 columns, max. 30 cm length
  • Heatup time: Typically 15 minutes 20 °C to 50 °C Cooldown time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Learn More
Dionex-Ultimate-3000-TCC-3000-HPLC-Column-Compartment-17923
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment

Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment

Cambridge Scientific ID #'s: 20020, 17920

Specification:

 

  • Temperature Range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature Accuracy: ±0.5 °C
  • Temperature Stability: ±0.1 °C
  • Temperature Precision: ±0.1 °C
  • Column Capacity: Up to 6 columns, max. 30 cm length
  • Heat-up Time: Typically 15 minutes 20 °C to 50 °C
  • Cooldown Time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
  • Switching valves: 1 or 2 thermostatted valves (2-position, 6-port, 2-position, 10-port, or 6-position, 7-port)

 

  • Watted parts

 

    • Stainless steel (1.4571, 316L), PEEK; Waste line: PTFE
    • Column switching valve (stainless steel): Vespel and DuraLife
    • Column switching valve (biocompatible): PEEK
    • Column switching valve (6-position, 7-port): Titanium
  • Safety features: Humidity sensor and gas sensor. Temperature control and temperature sensors

 

  • User input/display

 

    • LCD-indicating system parameters
    • Standby button
    • 3 LEDs for status monitoring (Power, Connected, Status)
    • 4 function keys for operation during initial installation and maintenance
  • GLP features: Electronic identification system for 4 columns. In Chameleon: Full support of automatic equipment qualification (AutoQ) and System System Wellness monitoring. All system parameters are recorded in the Chromeleon Audit Trail.
  • Power requirements: 100 - 120 V, 60 Hz; 200 - 240 V, 50 Hz, max. 150 VA
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 17 x 42 x 51 cm (6.7 x 16.5x 20 in)  
  • Weight: 13.2 kg (29.0 lbs)
Learn More
Dionex-Ultimate-3000-TCC-3000SD-HPLC-Column-Compartment-20020
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment

Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment

Cambridge ID #: 18418

Specification:

 

  • Temperature Range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature Accuracy: ±0.5 °C
  • Temperature Stability: ±0.1 °C
  • Temperature Precision: ±0.1 °C
  • Column Capacity: Up to 6 columns, max. 30 cm length
  • Heat-up Time: Typically 15 minutes 20 °C to 50 °C
  • Cooldown Time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
  • Switching valves: 1 or 2 thermostatted valves (2-position, 6-port, 2-position, 10-port, or 6-position, 7-port)

 

  • Watted parts

 

    • Stainless steel (1.4571, 316L), PEEK; Waste line: PTFE
    • Column switching valve (stainless steel): Vespel and DuraLife
    • Column switching valve (biocompatible): PEEK
    • Column switching valve (6-position, 7-port): Titanium
  • Safety features: Humidity sensor and gas sensor. Temperature control and temperature sensors

 

  • User input/display

 

    • LCD-indicating system parameters
    • Standby button
    • 3 LEDs for status monitoring (Power, Connected, Status)
    • 4 function keys for operation during initial installation and maintenance
  • GLP features: Electronic identification system for 4 columns. In Chameleon: Full support of automatic equipment qualification (AutoQ) and System System Wellness monitoring. All system parameters are recorded in the Chromeleon Audit Trail.
  • Power requirements: 100 - 120 V, 60 Hz; 200 - 240 V, 50 Hz, max. 150 VA
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 17 x 42 x 51 cm (6.7 x 16.5x 20 in)  
  • Weight: 13.2 kg (29.0 lbs)
Learn More
Dionex-Ultimate-3000-TCC-3200-HPLC-Column-Compartment-18418
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping