We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Column Compartment / Heater: 1-15 of 20

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment / Heater

Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment / Heater

Cambridge ID #: 18418

Specification:

 

  • Temperature Range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature Accuracy: ±0.5 °C
  • Temperature Stability: ±0.1 °C
  • Temperature Precision: ±0.1 °C
  • Column Capacity: Up to 6 columns, max. 30 cm length
  • Heat-up Time: Typically 15 minutes 20 °C to 50 °C
  • Cooldown Time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
  • Switching valves: 1 or 2 thermostatted valves (2-position, 6-port, 2-position, 10-port, or 6-position, 7-port)

 

  • Watted parts

 

    • Stainless steel (1.4571, 316L), PEEK; Waste line: PTFE
    • Column switching valve (stainless steel): Vespel and DuraLife
    • Column switching valve (biocompatible): PEEK
    • Column switching valve (6-position, 7-port): Titanium
  • Safety features: Humidity sensor and gas sensor. Temperature control and temperature sensors

 

  • User input/display

 

    • LCD-indicating system parameters
    • Standby button
    • 3 LEDs for status monitoring (Power, Connected, Status)
    • 4 function keys for operation during initial installation and maintenance
  • GLP features: Electronic identification system for 4 columns. In Chameleon: Full support of automatic equipment qualification (AutoQ) and System System Wellness monitoring. All system parameters are recorded in the Chromeleon Audit Trail.
  • Power requirements: 100 - 120 V, 60 Hz; 200 - 240 V, 50 Hz, max. 150 VA
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 17 x 42 x 51 cm (6.7 x 16.5x 20 in)  
  • Weight: 13.2 kg (29.0 lbs)
Learn More
Dionex-Ultimate-3000-TCC-3200-HPLC-Column-Compartment---Heater-18418
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex AS50 HPLC Column Compartment / HeaterImage Coming Soon

Dionex AS50 HPLC Column Compartment / Heater

Cambridge ID #: 18396

The Dionex Autoselect™ AS50 Autosampler precisely delivers from 1.0 to 99.9 µL (in 0.1 µL increments) or 100 to 1000 µL (in 1 µL increments) of sample to an injection valve. Two types of trays are available for sample vials: one for 2 mL vials and one for 10 mL vials. During sampling, the tray remains stationary and a sampling needle arm moves from vial to vial. Up to 99 injections can be taken from each vial. The AS50 can be controlled locally, from the front panel keypad and display, or remotely, with a personal computer running Chromeleon software installed. The AS50 can be configured with PEEK flow paths and components for ion chromatography (IC) applications, or with stainless steel flow paths and components for high-performance liquid chromatography applications (HPLC).

 

Specification:

 

  • Ambient Operating Temperature: 10 °C to 40 °C (50 °F to 104 °F)
  • Operating Humidity: 10% to 95% relative humidity, non-condensing
  • Decibel Level: <60 db (at “A WEIGHING” setting)
  • Dimensions: 58 cm high x 30 cm wide x 46 cm deep (23 in x 12 in x 19 in)
  • Weight: < 30 kg (< 65 lb)
  • Injections Per Vial: 1 to 99

 

  • Variable Volume Range

 

    • 1 to 100 µL in 0.1 µL increments
    • 100 to 1000 mL in 1 µL increments

 

  • Injection Loop Size

 

    • IC version: 25 µL standard; other sizes are available
    • HPLC version: 20 µL standard; other sizes are available
Learn More
Dionex-AS50-HPLC-Column-Compartment---Heater-18396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment / Heater

Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment / Heater

Cambridge ID #: 17923

Specifications:

  • Temperature range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature accuracy: ±0.5 °C
  • Temperature stability: ±0.1 °C Temperature precision: ±0.1 °C
  • Column capacity: Up to 6 columns, max. 30 cm length
  • Heatup time: Typically 15 minutes 20 °C to 50 °C Cooldown time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Learn More
Dionex-Ultimate-3000-TCC-3000-HPLC-Column-Compartment---Heater-17923
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Agilent 1200 Series - G1316A HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 17898, 18526

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment---Heater-17898
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment / Heater

Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment / Heater

Cambridge ID #: 17920

Specifications:

  • Temperature range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature accuracy: ±0.5 °C
  • Temperature stability: ±0.1 °C Temperature precision: ±0.1 °C
  • Column capacity: Up to 6 columns, max. 30 cm length
  • Heatup time: Typically 15 minutes 20 °C to 50 °C Cooldown time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Learn More
Dionex-Ultimate-3000-TCC-3000SD-HPLC-Column-Compartment---Heater-17920
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G1316C HPLC Column Compartment / HeaterImage Coming Soon

Agilent 1290 Series - G1316C HPLC Column Compartment / Heater

Cambridge ID #: 17708

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---G1316C-HPLC-Column-Compartment---Heater-17708
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - K1316C HPLC Column Compartment / HeaterImage Coming Soon

Agilent 1290 Series - K1316C HPLC Column Compartment / Heater

Cambridge ID #: 17707

The Agilent 1290 Infinity Thermostatted Column Compartment is a stackable temperature-controlled column compartment for LC. It is available as standalone module or as a component of an Agilent 1290 Infinity system. It is used for heating and cooling to meet extreme requirements of retention time reproducibility.

Specifications:

  • Temperature range:
    • 10 degrees below ambient to 100 °C
    • up to 80 °C: flow rates up to 5 ml/min
    • up to 100 °C: flow rates up to 2.5 ml/min
  • Temperature stability: ± 0.05 °C
  • Temperature accuracy:
    • ± 0.8 °C
    • ± 0.5 °C
  • Warm-up/cool-down time:
    • 5 min from ambient to 40 °C
    • 10 min from 40 – 20 °C
  • Dead volume:
    • 1.6 µl low dispersion heat exchanger
    • 3 µl left heat exchanger
    • 6 µl right heat exchanger
Learn More
Agilent-1290-Series---K1316C-HPLC-Column-Compartment---Heater-17707
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316D HPLC Column Compartment / Heater

Agilent 1100 Series - G1316D HPLC Column Compartment / Heater

Cambridge ID #: 17701

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316D-HPLC-Column-Compartment---Heater-17701
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters WAT270852 HPLC Column Compartment / Heater

Waters WAT270852 HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 16972, 11731, 14607, 13888, 18488, 16627, 16311, 13099, 13856, 13098, 13721, 12388, 13904, 12912, 17869, 14136

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-WAT270852-HPLC-Column-Compartment---Heater-16972
By clicking below we can further assist you with your inquiry. Inquire 16 In Stock Worldwide Shipping
Thermo Forma Ultimate TCC-3000RS HPLC Column Compartment / Heater

Thermo Forma Ultimate TCC-3000RS HPLC Column Compartment / Heater

Cambridge ID #: 14871

Operate at temperatures up to 110°C with no compromise in precision or accuracy. The Thermo Scientific Dionex UltiMate TCC-3000RS Rapid Separation Thermostatted Column Compartment enables the use of high column temperatures for ultrafast and conventional liquid chromatography (LC) applications to reduce system back pressures and run times. Dispersion-reduced precolumn heating and postcolumn cooling technology ensures optimal separation, run time, and detection under challenging conditions. These low-volume cooling and heating components can be easily exchanged to optimally match column flow and mobile phase requirements.

Specifications:

  • Temperature Range:5°C - 110°C
  • Temperature Accuracy:+/- 0.5°C
  • Recommended Eluent Preheater Volume:2 uL
  • Cool Down Time:15 min
  • Maximum Column Length: 30 cm
  • Column Capacity:12
  • Weight: 9 kg
  • Power Requirements:150V
  • Pressure Capacity: 125 MPa
Learn More
Thermo-Forma-Ultimate-TCC-3000RS-HPLC-Column-Compartment---Heater-14871
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Agilent 1100 Series - G1316A HPLC Column Compartment / Heater

Cambridge Scientific ID #'s: 14782, 14774, 18443, 13938, 13993, 15080, 14001, 17470, 14783, 15133, 17963, 13800, 16143, 14767, 17962, 15997, 16318

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment---Heater-14782
By clicking below we can further assist you with your inquiry. Inquire 17 In Stock Worldwide Shipping
Waters 186001863 HPLC Column Compartment / HeaterImage Coming Soon

Waters 186001863 HPLC Column Compartment / Heater

Cambridge ID #: 13073

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-186001863-HPLC-Column-Compartment---Heater-13073
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Alliance - WAT270852 HPLC Column Compartment / Heater

Waters Alliance - WAT270852 HPLC Column Compartment / Heater

Cambridge ID #: 7673

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Alliance---WAT270852-HPLC-Column-Compartment---Heater-7673
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Compartment HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Compartment HPLC Column Compartment / Heater

Cambridge ID #: 9245

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Compartment-HPLC-Column-Compartment---Heater-9245
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Heater Module. HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Heater Module. HPLC Column Compartment / Heater

Cambridge ID #: 7394

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Heater-Module.-HPLC-Column-Compartment---Heater-7394
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping