We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Column Compartment: 61-75 of 178

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G1311A HPLC Quaternary Pump

Agilent 1200 Series - G1311A HPLC Quaternary Pump

Cambridge ID #: 20563

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-20563
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

Cambridge ID #: 15899

Specifications: 

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Noise: ± 0.75 x 10 -5 AU, at 254 nm
  • Drift: 3 x 10-4AU/hr, at 254 nm
  • Linearity: >2 AU upper limit
  • Wavelength range: 190-600 nm
  • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
  • Maximum data rate: 55 Hz
Learn More
Agilent-1200-Series---G1314C-HPLC-Variable-Wavelength-Detector-15899
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1315C HPLC Variable Wavelength Detector

Agilent 1200 Series - G1315C HPLC Variable Wavelength Detector

Cambridge ID #: 20125

Specifications: 

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Noise: ± 0.75 x 10 -5 AU, at 254 nm
  • Drift: 3 x 10-4AU/hr, at 254 nm
  • Linearity: >2 AU upper limit
  • Wavelength range: 190-600 nm
  • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
  • Maximum data rate: 55 Hz
Learn More
Agilent-1200-Series---G1315C-HPLC-Variable-Wavelength-Detector-20125
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1315D HPLC Diode Array Detector

Agilent 1200 Series - G1315D HPLC Diode Array Detector

Cambridge ID #: 20562

The Agilent 1200 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1315D-HPLC-Diode-Array-Detector-20562
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1321A HPLC Fluorescence Detector

Agilent 1200 Series - G1321A HPLC Fluorescence Detector

Cambridge ID #: 17897

This user-friendly detector brings high sensitivity fluorescence detection for you needs whether used alone or in an automated Agilent 1200 Series system. One run will provide quantitative data and fluorescence spectra all the while improving sensitivity and selectivity with the simultaneous multi-wavelength detection capabilities.

Specifications:

  • Environment: 0 – 40°C
  • Dimensions: 17 x 13.5 x 5.5 in
  • Weight:5 lbs
  • Flow Cells: 8 uL volume and 20 bar pressure max
  • Scan Speed: 28 ms/data point
  • Step Size: 1 – 20 nm
  • Wavelength Repeatability: +/- 0.2 nm
  • Wavelength Accuracy: +/- 3 nm
  • Single Wavelength Operation: RAMAN (H2O) > 500
  • Ex: 350 nm
  • Em: 397 nm
  • Dark Value: 450 nm
  • Dual Wavelength Operation: RAMAN (H2O) > 300
  • Ex: 350 nm
  • Em: 397 nm
  • Dark Value: 450 nm
  • Pulse Frequency: 296 Hz for single signal mode. 74 Hz for economy mode
  • Maximum Data Rate: 18 Hz
  • Excitation Monochromator Range: 200 – 1200 nm
  • Bandwidth: 20 nm
  • Emission Monochromator Range: 200 – 1200 nm
  • Bandwidth: 20 nm
Learn More
Agilent-1200-Series---G1321A-HPLC-Fluorescence-Detector-17897
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1322A HPLC Degasser

Agilent 1200 Series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 16301, 20559

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1200-Series---G1322A-HPLC-Degasser-16301
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1329A HPLC Autosampler

Agilent 1200 Series - G1329A HPLC Autosampler

Cambridge ID #: 20565

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1329A-HPLC-Autosampler-20565
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16330, 16315, 15076

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-16330
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Cambridge Scientific ID #'s: 20340, 16349

Features:

  • Advanced temperature controlled detector optics ready to use within two hours of installation
  • Automatic zero and automatic purge combined with a recycle valve for automatic solvent recycling allow uninterrupted operation
  • Automatic light intensity control circuit to ensure the optimum performance of the optics
  • Integrated diagnostics for efficient troubleshooting
  • Built-in refractive index calibration
  • Front access to valves and capillaries for easy maintenance
  •  

Specifications:

  • Detection type: Refractive Index
  • Refractive index range: 1.00 – 1.75 RIU, calibrated
  • Measurement range: +/- 600 x 10-6 RIU
  • Optics temperature control: 5 ° C above ambient to 55 ° C
  • Sample cell volume: 8uL
  • Maximum pressure: 5 bar (0.5Mpa)
  • Maximum flow rate: 5mL/minute
  • Valves: Automatic purge and automatic solvent recycle
  • Volumes: Inlet port to sample cell 62uL, inlet port to outlet port 590uL
Learn More
Agilent-1200-Series---G1362A-HPLC-Refractive-Index-Detector-20340
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1367A HPLC Capillary Pump

Agilent 1200 Series - G1367A HPLC Capillary Pump

Cambridge ID #: 20388

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367A-HPLC-Capillary-Pump-20388
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1379B HPLC Degasser

Agilent 1200 Series - G1379B HPLC Degasser

Cambridge Scientific ID #'s: 20124, 20389

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1379B-HPLC-Degasser-20124
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G2226A HPLC Nano Pump

Agilent 1200 Series - G2226A HPLC Nano Pump

Cambridge ID #: 12658

This Agilent 1200 Model G2226A ( G 2226A, G 2226 A, G2226 A ) Series Nano (NanoFlow) Pump is in excellent condition!  The Agilent 1200 Series nanoflow pump uses a unique solvent delivery technology optimized for nanoliter-per-minute flows and features EFC (Electronic Flow Control) with active feedback and real time flow adjustment. EFC is the gold standard for robust and reliable nanoflow performance and delivers the precise flow and gradient performance necessary for retention time reproducibility and stable ion generation essential for high sensitivity nanospray MS performance.

Features:

  • Electronic Flow Control (EFC) provides real-time adjustment of the flow rate throughout the analysis for reliable and reproducible results.
  • Micro vacuum degassing with very low internal volume per channel (1 mL) for fast changeover of mobile phase and quick purge.
  • Control from handheld controller for convenient local status monitoring.
  • 2nd generation flow sensors.
  • Application focus: High resolution separations and high sensitivity MS detection. Proteomics is a typical application area for the nanoflow pump.

 

Learn More
Agilent-1200-Series---G2226A-HPLC-Nano-Pump-12658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative AutosamplerImage Coming Soon

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G4208A HPLC Communication Module

Agilent 1200 Series - G4208A HPLC Communication Module

Cambridge ID #: 19260

Agilent 1200 Series - G4208A

 

The Instant Pilot provides complete local control and monitoring of a single module or an entire Agilent 1100/1200/1260 and 1290 Series HPLC system. There is no data evaluation in the Instant Pilot. The Instant Pilot allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses and basic diagnostics and maintenance.

 

Specifications:

 

  • Dimensions (W x D x H): 130 × 225 × 35 mm (5.1 × 8.9 × 1.4 inches)
  • Weight: 0.8 kg (1.76 lbs)
  • Line Voltage: 22 VDC, ± 10 %
  • Power Consumption: 7 W
  • Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95%, at 25 – 40 °C (77 – 104 °F)
  • Operating Altitude: Up to 3000 m (9842 ft)
  • Non-Operating Altitude: Up to 4600 m (15092 ft)
Learn More
Agilent-1200-Series---G4208A-HPLC-Communication-Module-19260
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1220 Infinity - G4294B HPLC System

Agilent 1220 Infinity - G4294B HPLC System

Cambridge ID #: 20010

Features:

This Agilent 1220 Infinity LC - G4294B has a Gradient Pump, Autosampler, Column oven and Diode Array Detector configuration. It also includes Agilent Instrument Utilities Software.

Specifications:

  • Weight: 43 kg (94 lbs)
  • Dimensions (height × width× depth): 640×370×485 mm (25.2×14.6×19.1 inches)
  • Line frequency:  50 or 60 Hz, ± 5 %
  • Power consumption: 240 VA / 210 W / 717 BTU
  • Ambient operating temperature: 4–55 °C (39–131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95 % r.h. at 40 °C (104 °F)

 

Learn More
Agilent-1220-Infinity---G4294B-HPLC-System-20010
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping