Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Diode Array Detector: 1-6 of 6

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1315A HPLC Diode Array Detector

Agilent 1100 Series - G1315A HPLC Diode Array Detector

Cambridge Scientific ID #'s: 19153, 18569, 19152

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19153
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Dionex Ultimate 3000 PDA-3000 HPLC Diode Array Detector

Dionex Ultimate 3000 PDA-3000 HPLC Diode Array Detector

Cambridge ID #: 18417

Specification:

 

  • Noise with Analytical or Semi-Preparative Cell Installed: <± 10 µAU at 254 nm, 2-second rise time, 4 nm bandwidth and flowing water at 1.0 mL/min. <± 15 µAU at 520 nm, 2-second rise time, 10 nm bandwidth and flowing water at 1.0 mL/min
  • Noise with Semi-Micro Cell Installed: <± 15 µAU at 254 nm, 2-second rise time, 4 nm bandwidth and flowing water at 1.0 mL/min. <± 15 µAU at 520 nm, 2-second rise time, 10 nm bandwidth and flowing water at 1.0 mL/min
  • Drift: <1 mAU/h at 254 nm and 520 nm, and flowing water (after warm-up); typically < 500 µAU/h
  • Wavelength Range: 190 to 800 mm
  • Wavelength Accuracy: ±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter
  • Resolution: 1 nm
  • Linearity: Corr. Coeff. > 99.95 and < 3% RSD up to 1.5 AU

 

  • Analytical Flow Cell

 

    • PEEK cell: 13 µL volume; 10 mm (0.394 in) path length
    • Stainless steel cell: 13 µL volume; 10 mm (0.394 in) path length

 

  • Semi-Micro Flow Cell

 

    • PEEK cell: 3.1 µL volume; 9 mm (0.35 in) path length
    • Stainless steel cell: 3.1 µL volume; 9 mm (0.35 in) path length
  • Semi-Preparative Flow Cell: 0.7 µL volume; 0.4 mm (0.02 in) path length

 

  • Maximum cell pressure

 

    • Analytical flow cell: <21 bar (300 psi) (PEEK); <35 bar (500 psi) (SST)
    • Semi-micro flow cell: < 21 bar (300 psi) (PEEK); < 35 bar (500 psi) (SST)
    • Semipreparative flow cell: < 100 bar (1450 psi)
  • Optical System: Single-beam, reverse-optics design with concave holographic grating
  • Photodiode Array: 1024 element
  • Pixel Resolution: 0.7 nm
  • Lamps: Deuterium lamp (30 W) for ultraviolet spectrum analysis. Tungsten lamp (15 W) for visible spectrum analysis.
  • Control: All parameters and functions controlled by Chromeleon software; the Chromeleon PC and the detector are connected through USB (Universal Serial Bus) 4 LEDs (Power, Run, Deuterium, Tungsten) for status monitoring.
  • GLP Features: In Chromeleon - Support of automatic equipment qualification (AutoQ) and System Wellness monitoring. All system parameters are logged in the audit trail.
  • Analog outputs: Four, 0-3 AU, independently selectable, 1000 mV range
  • Voltage out: 1 V output
  • Power Requirements: 85 to 265 VAC, 47 to 63 Hz auto-sensing; no adjustment necessary)
  • Typical Input Power: 100 W
  • Maximum Line Draw: 3.5 A at 110 VAC at power-up
  • Fuses: Two 4.0 amp fast-blow IEC 127 fuses
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 19 x 52 x 51 cm (7.5 x 16.5 x 20 in.)
  • Weight: 19 kg (41.8 lbs)
Learn More
Dionex-Ultimate-3000-PDA-3000-HPLC-Diode-Array-Detector-18417
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 2996 HPLC Diode Array Detector

Waters 2996 HPLC Diode Array Detector

Cambridge Scientific ID #'s: 17867, 19078, 11317, 14601, 16584

Waters 2996 Photo Diode Array (PDA) Detector has uniquely-integrated software and optics innovations that deliver no-compromise chromatographic and spectral sensitivity, reliability and ease of use for analytical and preparative separations. Advanced spectral analysis enhances component recognition and homogeneity assessment.

 

Features:

  • Maximum chromatographic sensitivity means unprecedented trace impurity detection and quantification.
  • Optimized spectral sensitivity and Waters purity algorithms mean definitive compound identification and co-elution detection.
  • Superior linearity range defined by a fixed optical bandpass
  • Simplified optics that are reliable and easy to maintain
  • Method development and validation are fast and straight forward with uncomplicated method development tools within Empower
  • Compliance-ready for the FDA Electronic Records and Electronic Signatures Rule
  • Start-up diagnostics that ensure detector performance prior to use

 

Specification:

  • Linearity range: 5% over -0.1 to 2.0 AU
  • Spectral resolution: 1.2 nm per photodiode
  • Baseline noise: 5 x 10 -5 AU peak-to-peak
  • Drift: 1 x 10 -3 AU/hour at 254 nm (after warmup)
  • Operating temperature: 4 to 40 ¡ãC (39 to 104 ¡ãF)
  • Operating humidity: 20 to 80% non-condensing
  • Wavelength accuracy: 1nm
  • Wavelength range: 190 to 800 nm
Learn More
Waters-2996-HPLC-Diode-Array-Detector-17867
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Waters 996 HPLC Diode Array Detector

Waters 996 HPLC Diode Array Detector

Cambridge Scientific ID #'s: 16935, 13096, 17870, 5767, 12385, 16656, 16657, 13902, 16254, 6542, 11732, 15110, 15109, 15108, 15244, 14274, 15104

Specifications:

  • Dimensions: 5 x 22 inches (29x56 cm)
  • Weight: 31 lbs (14.3 kg)
  • Wavelength range: 190 to 800 nm
  • Wavelength accuracy: +1 nm
  • Linearity range: 5% at 2.0 AU, propylparaben, at 258
  • Spectral resolution: 2 nm
  • Baseline noise: +1.5 x 10-5 AU peak-to-peak, dry, at 254 nm
  • Drift: 1 x 10-3 AU/hour at 254 nm (after warm-up)
Learn More
Waters-996-HPLC-Diode-Array-Detector-16935
By clicking below we can further assist you with your inquiry. Inquire 17 In Stock Worldwide Shipping
Agilent 1100 Series - G1315B HPLC Diode Array Detector

Agilent 1100 Series - G1315B HPLC Diode Array Detector

Cambridge Scientific ID #'s: 16038, 18442

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-16038
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters 650E Advanced PPS HPLC Diode Array Detector

Waters 650E Advanced PPS HPLC Diode Array Detector

Cambridge ID #: 5239
  • Controller, Pump & Detector Purification System
  • Learn More
    Waters-650E-Advanced-PPS-HPLC-Diode-Array-Detector-5239
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping